HomeMy WebLinkAboutEngineer PlanNorth Dennis Road
Public Way
i
/ S 85'51'47" E
1.) Assessor's Map 109 Parcel 66
2.) Bk 30669 Pg. 323
3.) Plan Book 177 Page 91
4.) This property is in the Zone II
Water Protection District
5.) This property is in Flood Zone X
Firm map 250001CO583J Dated: 7/16/14
L = 69.34 38.50 R = 700.00'
/ R = 40.00ii
L = 100.08'
Lot 19 " J(50 0) I Petto _
15,000± Sq. Ft. ( _ _ Filter
� y l
W� Pool ,I(4 8) 20.5'
{ /'_
(48.2) / C1
} /!/ House #2 ��� Note x/19
4 Bedroom ��_(49.2) ST� ` Apple
1 w { { TOF EL 50.0 Tree /
(�
O Q ° _ — ; t' _ r ilk Chom—o in �F
-0 { D/W { ` ' = : 1111 ice / Pe
CY Deck _W
/ n { _ �waE f —'" �- See Note #19
Z l- TBM EL = 49.25 f
t' Existing Septic (49.2) Top of Conch a per Septic As—Built
(Assume (4
48 (47.2)W
} Found S 84`48 25
} Concrete
{
Bound ��'�� 181.75'
Map 109
{ Parcel 67
(48.3)
LOCATION OF UTILITIES IS APPROXIMATE AND ALL 20
UNDERGROUND AND OVERHEAD UTILITIES MUST BE
DETERMINED IN THE FIELD PRIOR TO COMMENCEMENT
OF ANY WORK, THIS INCLUDES, BUT NOT LIMITED T0,
REOUESTS TO DIGSAFE, ANY PRIVATE UTILITY COMPANIES
AND THE LOCAL WATER DEPARTMENT.
Yarmouth Health Department
"PROVED
�'/ /
6�
Name Date
GRAPHIC SCALE
10 20 4D
( IN FEET )
1 inch = 20 ft.
Prop.
X11
8
10.0'
+
SAS
+
(/ +
+ (46.5)
+ o
'P +
+
+
l
a
+
•
DB +.++
48 ` 1
46
ny
l l�
400 Mil I fOJ I
Liner 46
44
7M
/44 0
3
n
(43.5) �
Proposed
2 Placid
it
App 0 6 2022
i HEALTH DEPT
I
{ Mop 110
} Parcel 13
{
SITE LOCUS
NOT TO SCALE
L, OFM,4,,,s5
Sr
PJ
EPHEyG
S No. 30398
Sewage Disposal System
Street South Yarmouth, MA
Prepared for:
Gail Marshall
2 Placid Street
South Yarmouth, MA 02664
Prepared by:
All Cape Septic LLC
618 Route 28
West Yarmouth, MA 02673
(508) 771-4200
all cap eseptic*gmail.com
Date: 03/07/22 Sheet 1 of 2 By: MA Check: SM Project No. AC -417
Revised Date: 04/02/22
CONSTRUCTION NOTES RAISE MIN, 20" DIAMETER COVER RAISE MIN. 20" DIAMETER COVER
1.) ALL WORK SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE,.TITLE 5 (310 CMR 15.000): TO WITHIN 6" OF FINISH GRADE TO WITHIN 6" OF FINISH GRADE
STANDARD REQUIREMENTS FOR THE SITING, CONSTRUCTION, INSPECTION, UPGRADE, AND EL=50.0±
EXPANSION OF ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS AND POR THE TRANSPORT
AND DISPOSAL. OF SEPTAGE, AND THE LOCAL BOARD OF HEALTH! REGULATIONS. 49.21 EL =
2.) ANY SEPTIC SYSTEM COMPONENT INSTALLEDINA LOCATION WHERE THERE IS POTENTIAL FOR
VEHICLES OR HEAVY EQUIPMENT TO PASS OVER IT SHALL BE DESIGNED TO WITHSTAND AN H-20 \//\/
LOADING. IF UNDER AN IMPERVIOUS SURFACE, SYSTEM SHALL BE VENTED TO THE ATMOSPHERE.
3.). TO MINIMIZE UNEVEN SETTLING, SEPTIC TANKS AND D -BOX SHALL BE INSTALLED ON A STABLE
MECHANICALLY -COMPACTED BASE ON SIX INCHES OF CRUSHED STONE.
4.) COVERS OVER THE INLET AND OUTLET TEES OF THE SEPTIC TANK; THE DISTRIBUTION 80X, AND
THE SOIL ABSORPTION SYSTEM SHALL BE RAISED TO WITHIN 6" OF FINAL GRADE. LEACHING
FIELDS, TRENCHES; AND OTHER SOIL ABSORPTION SYSTEMS WITHOUTACCESSMANHOLES SHALL �48-.
HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4" PVC PIPE PLACED GXls
VERTICALLY TO THE BOTTOM OF THE. SOIL ABSORPTION SYSTEM PITH A, CAP, TIED WITH MAGNETIC
MARKING TAPE, ACCESSI8LE TO WITHIN 3" OF FINAL GRADE..
5.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT, PIPE SHALL BE LAID ON A
MINIMUM. CONTINUOUS (MADE OF NOT LESS THAN 2% FROM THE BUILDING TO THE SEPTIC TANK,
AND NOT LESS THAN 1% OTHERMSE.
6.) DISTRIBUTION LINES FOR THE SOIL ABSORPTION SYSTEM SHALL BE 4" DIAMETER SCHEDULE 40
AVC (OR EQUIVALENT) LAID AT 0.005 FT/FT; UNLESS OTHERWISE NOTED. LINES SHALL BE CAPPED
AT END OR AS NOTED,
7,). LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRST TWO (2) FEET BEFORE
PITCHING TO THE SOIL ABSORPTION SYSTEM. DISTRIBUTION BOX SHALL BE WATER TESTED TO
ASSURE EVEN DISTRIBUTION,
8,) GROUT TO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES
IN ORDER TO PROVIDE A WATERTIGHT SEAL.
9. HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVER THE LIMITS OF THE SEWAGE
DISPOSAL FIELD DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM,
10) IN ACCORDANCE WITH 310 CMR 15,221, ALL. SYSTEM COMPONENTS SHALL BE MARKED WITH
MAGNETIC MARKING TAPE,
11.) THERE ARE NO KNOWN WELLS OR WETLANDS WITHIN 150' OF THE PROPOSED SOIL ABSORPTION SYSTEM.
12.) FROM THE DATE OF THE INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF
THE CERTIFICATE OF COMPLIANCE, THE. PERIMETER SHALL BE STAKED AND FLAGGED TO PREVENT
USE OF THE AREA THAT MAY CAUSE DAMAGE TO THE SYSTEM.
11) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS
CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES SHALL BE APPROVED IN WRITING BY THE ENGINEER.
14.) THE. BOARD OF HEALTH REQUIRES INSPECTION OF ALL CONSTRUCTION BY AN AGENT OF THE
BOARD OF HEALTH AND.. THE DESIGNER. THE DESIGNER SHALL CERTIFY IN WRITING THAT THE
SEWAGE DISPOSAL SYSTEM WAS INSTALLED IN ACCORDANCE WITH THE TERMS OF THE PERMIT
AND THE APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS REQUESTED.
15.) LOCATION OF -UTILITIES IS APPROXIMATE AND CONTRACTOR SHALL 8E RESPONSIBLE FOR
DETERMINING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR To
COMMENCEMENT OF ANY WORK. THIS INCLUDES, BUT IS NOT LIMITED TO, REQUESTS TO DIGSAFE,
ANY PRIVATE. UTILITY COMPANIES, AND THE LOCAL WATER DEPARTMENT.
16.) CONTRACTOR SHALL VERIFY THAT ALL WASTEUNES ARE CONNECTED BY WATER TESTING
WITHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS.
17.) CONTRACTOR SHALL VERIFY EXISTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY
SEPTIC SYSTEM COMPONENTS.
18.) TEST HOLES COMPLETED PER STATE ENVIRONMENTAL CODE, TITLE 5. SOILS CAN BE
VARIABLE AND TEST HOLE DATA IS NO GUARANTEE OF SOL CONDITIONS IN OTHER AREAS. IF
SOILS DIFFER FROM THOSE SHOWN IN THE SOILS LOGS, DESIGN ENGINEER IS TO INSPECT THE
SOILS PRIOR TO PROCEEDING WITH INSTALLATION. OF ANY SEPTIC COMPONENTS.
19.) EXISTING SEPTIC COMPONENTS TO BE LOCATED, PUMPED DRY, FILLED WRH CLEAN SAND AND
ABANDONED IN PLACE OR REMOVED AS REQUIRED. AREA TO BE COMPACTED TO MINIMIZE SETTLING.
Bedroom
#3 Bedroom
#4_
Bath
Firt Floor
L.T.S.
Family
Room
Living
Roam
Second Floor
N.T.S.
Bedroom
#1
Kitchen Bedroom
Both 1 #2
Test Hole t (EL=47.81)
I GJ I rlULr LUC7
M
Elev.
Proposed
Soil Class
47.1±
OVERLAP
OVERLAP
40 Mil
A
44.4
GEOTEXTILE
GEOTEXTILE
Liner
44.4
B
FABRIC
FABRIC
44.5
n
Prop.
Tee
C
/
/
5't \`
46.0 0
45.75 J
44.37 44.2
c;±•:::=-1 43.9 }
3/4" to
v
See Note,/�1-1/2"
STON
GAS BAFFLE
3 `^
(Double wash
6' rushed DB -3 H-20
Stone
D -BOX
FOUR (4) 500 GALLON H-20 PRECAST
41,9
CONCRETE LEACH
CHAMBERS WITH
3' OF
EXISTING
1,000 GALLON
45'±--� �12'±-�
STONE ON ENDS
AND 3' ON SIDES
SEPTIC TANK
}
LEACH
CHAMBERS
5.1'
END ME
Bedroom
#3 Bedroom
#4_
Bath
Firt Floor
L.T.S.
Family
Room
Living
Roam
Second Floor
N.T.S.
Bedroom
#1
Kitchen Bedroom
Both 1 #2
Test Hole t (EL=47.81)
I GJ I rlULr LUC7
Depth
Elev.
Layer
Soil Class
Soil Color
Other
0"-5"
47.4
A
Loamy Sand
10YR3/2
5"-41"
44.4
B
Loamy Sand
10YR5/6
41"-132"
36.8
C
Medium
Sand
2.5Y6/6
�pP DATE OF TESTING: 1/27/22
SOIL EVALUATOR: DAVID 0. FLAHERTY JR.
h� ! WITNESS: PHILP RENAUD YARMOUTH HEALTH AGENT
PERCOLATION RATE HOLE #1i LESS THAN < 2 MIN/INCH
NO GROUNDWATER ENCOUNTERED
NO MOTTLING ENCOUNTERED
FLOW PROFILE
NOT TO SCALE EL=36.8 Bottom Test Hole
SYSTEM DESIGN CALCULATIONS
SEWAGE DESIGN FLOW: EXISTING FOUR BEDROOM DWELLING 0 110 GPD/BEDROOM = 440 GPD
(MINIMUM DESIGN REQUIRED 440 GPD)
SEWAGE DESIGN FLOW PROVIDED: FOUR (4) 500 GALLON H2O CONCRETE CHAMBERS
WITH 3' STONE ON THE ENDS` AND 3' STONE ON THE SIDES
Vt = [(40.0 x 10.83) + 2(40.0 + 10.83) (2) x .74 = 471 GPD PROVIDED
471 GPD PROVIDED > 440 GPD REQUIRED
SEPTIC TANK CAPACITY REQUIRED: 440 GPD X'200 =.880 (MINIMUM)
SEPTIC TANK CAPACITY PROVIDED: 1,000 GALLON SEPTIC TANK (EXISTING)�..���
A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN FLOW Til •!3�''f30 M'o
Proposed Sewage
2 Placid
APR 0 6 2022
( HEALTHDEPT
Disposal System
Street
South Yarmouth, MA
Prepared for:
Gail Marshall
Prepared by:
All Cape Septic and Survey
618 Route 28
West Yarmouth, MA 02673
(508) 771-4200
ollcopesepticogmail. com
Date: 03/07/22 Sheet 2 of 2
Revised Date: 04/02/22 Project No. AC -417-2