HomeMy WebLinkAboutReview Chceklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 97 Lot // Zone of Contribution: In✓ Out_ Acreage/6 ,S 4/6
p Commercial: Residential: I�
Street: / .7 mo y0 0 rr, Oy 'cl
Village: Floor Plan: #Bedrooms: j
Owner:KQ r-) A.1 q/`v Installer: R o ij 6 rt C L; 1 c! s �n,3
Address: Phone: SDR .3`r g- _I SS6
Phone:
Builder: Engineer: ! ow n, C
Address: D2s 36 �p t
Phone: J cx--L/i5 4//
Phone:
N/A YES NO
1. Required#of copies received
2.Date of soils exam and percolation test not older than 2 years 1 .
3.4-5 ft of naturally occurring pervious material, above water table 1.-----
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: V
5.Water line 10 ft from septic components Var.: V
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: ✓
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: tZ
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: V
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.:
V
15. System not in top or subsoil(A,B horizons)or 5' removal /-
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 'A"preferred 1/
18. System meets breakout requirements PVC liner: Wall: V
19. Specified tee sizes are proper, gas baffle on outlet tee l/
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox
V
24. Manhole covers within 6"of grade,pump chamber cover to grade \//
25. Inspection port on plastic chambers/leach field K/
26. Electrical permit for pump chamber/Separate meter for duplexes V
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
k‘.728. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber 1/-
31.Engineer to inspect and certify soils: wall: commercial: V
•
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee,installer signature
35.Foundation footing min.2 feet above adjusted ground water for new house 1/
36. Deed Restriction required max. #bedrooms: max.flow: gpd t/
37. Check area lots for groundwater/Label groundwater in Assessor's Map t/
Plan reviewed b • _ A
6 03 03