Loading...
HomeMy WebLinkAboutReview Chceklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 97 Lot // Zone of Contribution: In✓ Out_ Acreage/6 ,S 4/6 p Commercial: Residential: I� Street: / .7 mo y0 0 rr, Oy 'cl Village: Floor Plan: #Bedrooms: j Owner:KQ r-) A.1 q/`v Installer: R o ij 6 rt C L; 1 c! s �n,3 Address: Phone: SDR .3`r g- _I SS6 Phone: Builder: Engineer: ! ow n, C Address: D2s 36 �p t Phone: J cx--L/i5 4// Phone: N/A YES NO 1. Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 1 . 3.4-5 ft of naturally occurring pervious material, above water table 1.----- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: V 5.Water line 10 ft from septic components Var.: V 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: ✓ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: tZ 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: V 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: V 15. System not in top or subsoil(A,B horizons)or 5' removal /- 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 'A"preferred 1/ 18. System meets breakout requirements PVC liner: Wall: V 19. Specified tee sizes are proper, gas baffle on outlet tee l/ 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox V 24. Manhole covers within 6"of grade,pump chamber cover to grade \// 25. Inspection port on plastic chambers/leach field K/ 26. Electrical permit for pump chamber/Separate meter for duplexes V 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size k‘.728. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 1/- 31.Engineer to inspect and certify soils: wall: commercial: V • 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee,installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 1/ 36. Deed Restriction required max. #bedrooms: max.flow: gpd t/ 37. Check area lots for groundwater/Label groundwater in Assessor's Map t/ Plan reviewed b • _ A 6 03 03