HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 6.0 Lot 0'3v Zone of Contribution: In Out )C Acreage 3i C991 5.r
Commercial: Residential: r/
Street: 1 }kr_).,--t - x �,vt
Village: 50..�1--i..>, Floor Plan: N c.) #Bedrooms: C
Owner: D 6 k -r---I c v Installer:
Address: Phone:
Phone:
Builder: -R6.A r-t uc 'BM-+-7s Engineer: ,4 LL C/
Address: Phone:
Phone:
N/A YES NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material,above water table /
4.Foundation 2 ft above high point of road H.P.: 24.1 Fnd:3 ' Var.: (.1 ' )( cite--
5. Water line 10 ft from septic components Var.: ,/
6. Benchmark indicated and shown-NGVD if near wetlands /
7. Septic tank minimum 10 ft from foundation, deck Var.: /
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: / q
9. Leaching minimum 100 ft from wetlands Var.: V
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11.Tank/leaching minimum 10 ft from property line Var.: V
12. System meets all other setback requirements Var.: I V
13.Uses adjustment for maximum high groundwater Var.: ,v
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5'removal I /
16.Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", '4"preferred ./
18. System meets breakout requirements PVC liner: Wall: ,/
19. Specified tee sizes are proper, gas baffle on outlet tee ,/
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
/
22. System adequately sized for its intended use ✓
23.Minimum 6"stone or compacted below tank and dbox ..i
24. Manhole covers within 6"of grade,pump chamber cover to grade /
25. Inspection port on plastic chambers/leach field ✓
26. Electrical permit for pump chamber/Separate meter for duplexes /
27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size /
28. Septic tank/pump chamber to be factory waterproofed I
29. Vent provided if leaching below 3 feet,under driveway/parking I
30. Buoyancy calculations for tank/pump chamber ,/
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33. H-20 loading is subject to vehicular traffic, groundwater ,/ 1
34. Title V Application and permit fee, installer signature v 44,
35. Foundation footing min.2 feet above adjusted ground water for new house ,/
36.Deed Restriction required max. #bedrooms: max. flow: gpd V/
37. Check area lots for groundwater/Label groundwater in Assessor's Map i
Plan reviewed by: 71t--p4- . 12../ 19 I Ze."=-1
6 03 03