HomeMy WebLinkAboutEngineer Plan.33
Yarmouth Health Department
Date
R 3 01 "
P' 1 ' Povemer
of97.58
97.59 __
x 99.42
3 + 98.77
+98,79 I-Ae0 -
+ 99.42
100,54
N x 99.26 ns
x 99.93
00
x 99.18 \
��'tH 4YF:
CHUR�C�LJR.
a
EXIS77NG CESSPOOLS
TO BE REMOVED
99.60
x
RECEIVED
MAR 2 2 2022
HEALTH DEPT,
97,20
97.26
96,89
CATCH BASIN /111
TCH BASIN
97.18 a
9.7,70
" `•". •r "\ 13,840±S.F. x yy.
161&
100.74 �t 0.72
x 100,45 \\ 99.59 N
\ Ni
101.33
EXISTING x 100.59 \
OUSE(#21)
100.26
DECK ^ /
100,74 i,1,` s 0.f%ii� -9.¢/. W
M Asa?
100.58
G
100,20 8H 10025
G 100.35
0
S 100.13y $� 100.04
9.70 X1'RFN� rW
tk - EI
PROPOSED SEPTIC TANK
CONTRACTOR MAY SUBSTITUTE WITH
AN INFILTRATOR IM1504 TANK
PROPOSED S,A.S.
2-500 GALLON CHAMBERS
SURROUNDED W/4' STONE
Val
C"
99,28
]N PIPE
9953
� OF MAss'c \
PETER T. 9� y
McENTEE
CIVIL
No. 35109
OWNER OF RECORD
KERINS, STEPHEN & ROLLA
22 SANDRICK ROAD
BELMONT, MA 02478
- 100 --EXISTING
CONTOUR
PLAN
x 100.98
EXISTING SPOT GRADE
MA
-W-EXISTING
WATER SERVICE
Engineers:
Engineering Works, Inc.
12 West Crossfield Rood
Forestdole, MA 02644
(508) 477-5313
- G -
EXISTING GAS SERVICE
DRAWN
P.T.M.
H. KL-
OVERHEAD WIRES
CHECKED
P.T.M.
[$Y�
TEST PIT
BENCHMARK
1 FGFNn
YARMOUTH
V
PAN
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED. BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL,
13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
NOT CONSIDERED TO BE A PROPERTY LINE SURVEY.
14, THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC
SYSTEM COMPONENTS NOT SHOWN ON THE PLAN
PARCEL ID: 94-14
PROPOSED
SEPTIC SYSTEM UPGRADE
PLAN
21 PAR 3
DRIVE, SOUTH YARMOUTH,
MA
Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth,
MA 02673
Engineers:
Engineering Works, Inc.
12 West Crossfield Rood
Forestdole, MA 02644
(508) 477-5313
Surveyors:
JC Engineering, Inc.
2854 Cranberry Hwy.
E.Worehom, MA 02538
(508) 273-0377
SCALE
1"=20'
DRAWN
P.T.M.
JOB. NO.
320-21
DATE
38/22
CHECKED
P.T.M.
SHEET N0.
1 Of 2
SEPTIC TANK
INSTALL RISERS & COVERS OVER INLET &
OUTLET AND SET TO 6' OF FINISH GRADE
T.O.F=101.44±
-F.G. EL.=100.8±
L = 14'
S=1% (Mw.)
4"SCH40 PVC
INV.=97.85
F.G. EL.=100.0±
48" LIQUID
LEVEL ADD
GAS BAFFLE
J PROPOSED SEPTIC TANK
CONNECT TO EXISTING SUITABLE SEWER PIPE/S
AT HOUSE, AT EXISITNG INV.=98.2±(venfv)
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES &
INVERTS EXITING HOUSE, PRIOR TO INSTALLATION.
2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND
TRUE TO GRADE ON A MECHANICALLY COMPACTED
SIX INCH CRUSHED STONE BASE, AS SPECIFIED
IN 310 CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL,
DESIGN CRITERIA
PROPOSED D -BOX
INSTALL RISER & COVER
SET TO 6" OF GRADE
L=9'
® S=1% (MIN.)
4"SCH40 PVC
F.G. EL.=99.7±
L=5'
O S=1% (MIN.)
4"SCH40 PVC
INV.=96.97J PROPOSED \- INV.=96.80
D -BOX
V.=97.60
3 OUTLETS INV.=95.90 -
TOP CONC. ELEV.= 97.0± -
BREAKOUT ELEV.= 96.40 -
INV. ELEV.= 95.90 -
BOTTOM ELEV.= 93.90-
4' OF NATURALLY OCCURRING
PERVIOUS MATERIAL
5' (MIN.) ABOVE G.W.
BOTTOM OF TEST PIT, EL.=87.7
SEPTIC SYSTEM PROFILE
NUMBER OF BEDROOMS: 3
SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF)
DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 330 GPD
DESIGN FLOW: 330 GPD
GARBAGE GRINDER: NO -not allowed with design
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
.74 GPD/SF
PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED
USE 2-500 GALLON LEACHING CHAMBERS IN SERIES
SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES
SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F.
BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F.
TOTAL AREA: .......................................................... _471.2 S.F.
DESIGN FLOW PROVIDED:0.74 GPD/SF(471.2 SF) = 348.7 GPD
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SHALL NOT BE AT, OR BELOW, EL.=96.4
FOR A DISTANCE OF 15' FROM THE EDGE
OF THE PROPOSED S.A.S.
PROPOSED S.A.S.
INSTALL RISER & COVER OVER EACH CHAMBER AND
SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT
r F.G. EL.=99.7±
MAINTAIN 2% SLOPE OVER S.A.S.
I / EFFECTIVE WIDTH = 12.8' 1
2-500 GALLON LEACHING CHAMBER
SURROUNDED WITH STONE AS SIL
0 T4TED
8.5' = 17.0'
LENGTH = <'
LEACHING SYSTEM SECTION
SOIL LOG
-2" LAYER OF 1/8" TO 1/2"
DOUBLE WASHED STONE
(OR FFr,' F3_i
4
TO 1-1/2" DOUBLE
WASHED STONE
DATE: FEBRUARY 23, 2022
SOIL EVALUATOR: PETER McENTEE PE(SE#1542)
WITNESS: PHIL RENAUD R.S. HEALTH AGENT
ELEV. TP DEPTH
99.2 0„
FILL
98.0 14"
LOAMY SAND
97.4 10YR 3/3
B 21„
LOAMY SAND
10YR 5/8
95.9 C 40"
MED. SAND
2.5Y 6/6
87.7 1 138"
PERC RATE <2 MIN/IN. "C" HORIZON
NO GROUNDWATER ENCOUNTERED
}„ HOUSE(#21)
-T.O.F.=101.44=
DECK
62.9'---_.
68.T e
\pp
SEPTIC LAYOUT
�
1 =1 lel tgl mg 1�1 til 1�1
11.9911,11, l til til lel I"71 til I�1 t7l
500 GALLON CAPACITY, H-10 LOADING
CHAMBERS
N.T.S.
33"
58"
PROPOSED
SEPTIC SYSTEM UPGRADE
4" KNOCKOUT
20" DIA, COVER
4" KNOCKOUTO / 4" KNOCKOUT
4" KNOCKOUT
21 PAR 3
DRIVE, SOUTH YARMOUTH,
500 GALLON CAPACITY, H-10 LOADING
CHAMBERS
N.T.S.
33"
58"
PROPOSED
SEPTIC SYSTEM UPGRADE
PLAN
21 PAR 3
DRIVE, SOUTH YARMOUTH,
MA
Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673
Engineers:
Surveyors:
SCALE
DRAWN
JOB. NO.
Engineering Works, Inc.
JC Engineering, Inc.
N.T.S.
P.T.M.
320-21
12 West Crossfield Road
Forestdale, MA 02644
2854 Cranberry Hwy.
E.Wareham, MA 02538
DATE
CHECKED
SHEET N0.
(508) 477-5313
(508) 273-0377
3/8/22
P.T.M.
2 Of 2