HomeMy WebLinkAboutEngineer PlanTOF= 100.80'+/- F.G. = 99.54'+/- 8' +/- I.f. EXISTING BUILDING COVER TO BE WITHIN 6" OF FINISHED GRADE MIN. 100.14' fi q s �i�xsm3reern�.maxN.ncm--��..�ar.+�rre�u '--��;ttav;cme. EXISTING 1000 GALLON SEPTIC TANK H-10 SECOND FLOOR PLAN RO NO SMP�� CPPB A� N AOu.v- 1 vl COVER TO BE WITHIN MIN. COVER TYP6" OF FINISHED GRADE COVER TO BE WITHIN 6" OF FINISHED GRADE 4" SCHED--4'0-- PVC PIPE (TYP) S=.01 FT/FT f4• 2 +/- Lf. MIN 99.52' ROUTE 6 N WATER TESTED FOR LEVEL 2' LEVEL 3' MAX. COVER S=.01 FT/FT 22.00+/- I.f. LESS 2' LEVE GAS 9AfRE- g\ 7.71, yi.oa/ 97.52' PLACE SEPTIC TANK AND 97.30' d -' TONE 1 / DIST. BOX ON 6"OFS OR MECHANICALLY COMPACTED SOIL PROPOSED 1000 GALLON DISTRIBUTION SEPTIC TANK BOX H-10 H-10 NOTE: 1, PROPERTY HAS IRRIGATION SYSTEM. 2. LOCATION OF GAS LINE. .,.. , /-02 1000 TANK 1981. LEACHING SITE PLAN I " - )n' A00 SEPTIC SYSTEM PROFILE NOT TO SCALE =96,26'- DINING 96,26' l' MIN. COVER Y' PEASTONE 961 mm asamamax T- f OVER TO •. DOUBLE WASHED STONE REQUESTED BOTTOM OF TEST HOLE DATE, 6/4/02 HEALTH DEFT.: AMY VANHONE v unit I 'ncc= n n71 SOIL EVALUATOR: TODD LABARGE DEPTH FROM SURFACE (INCHES) SOIL HORIZONv SOILTEXTURE (USDA) SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER (STRUCTURE. 0-9 DINING LOAMY 1OYR 3/2 - KITCHEN SAND LIVING GARAG B LOAMY IOYR 5/6 - N BATH N, 32-120 GASa FINE 1OYR 6/8 Q 5% GRAVEL SAND PORCH 6 0 TOBED BED 100.80' c� FLAGSTON 99X67 9 4 BM OF PATI❑ 2 ' p oD CONC. BH W EXISTING( O O 100.00' 0 1000 GAL \ 8X04'.: 1 t_ TONAL_. - _�1� NOTE: 1, PROPERTY HAS IRRIGATION SYSTEM. 2. LOCATION OF GAS LINE. .,.. , /-02 1000 TANK 1981. LEACHING SITE PLAN I " - )n' A00 SEPTIC SYSTEM PROFILE NOT TO SCALE =96,26'- DINING 96,26' l' MIN. COVER Y' PEASTONE 961 mm asamamax T- f OVER TO •. DOUBLE WASHED STONE REQUESTED BOTTOM OF TEST HOLE DATE, 6/4/02 HEALTH DEFT.: AMY VANHONE v unit I 'ncc= n n71 SOIL EVALUATOR: TODD LABARGE DEPTH FROM SURFACE (INCHES) SOIL HORIZONv SOILTEXTURE (USDA) SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER (STRUCTURE. 0-9 A LOAMY 1OYR 3/2 - SAND 9-32 B LOAMY IOYR 5/6 - SAND 32-120 C FINE 1OYR 6/8 - 5% GRAVEL SAND 5• PERC AT OL " GROUNDWATER AT 9 ELEV. 89.43' <2 --MIN. FERC 25 GALS. 25 GAL 0 15:00 MIN USING INDEX WELL AIW-230 AND USGS GROUNDWATER ELEVATIONS FOR 05/02 WATER LEVELRANGE - B WELL READING - 24.1' ADJUSTMENT - 2.4' ADJUSTED GROUND WATER ELEVATION 98.93'-(9.5)+(2.4-1.0)'=90.83' DESIGN CALCULATIONS: 90.83' NOTES: -Ig-r. SMALL RD. LOCUS MAP NOT TO SCALE 1. SEPTIC SYSTEM SHALL BE INSTALLED ACCORDING TO 310 CMR 15.00 (TITLE 5)AND THE TOWN OF _YARMOUTH BOARD OF HEALTH REGULATIONS. 2. ALL PIPES SHALL BE 4" SCHEDULE 40 PVC 3. THE DISTRIBUTION BOX SHALL BE WATER TESTED TO INSURE LEVELNESS AND EQUAL FLOW. * 4. THE INSTALLER IS TO VERIFY THE LOCATION OF UTILITIES AND SEWER LINE ELEVATIONS PRIOR TO INSTALLATION. 5. EXCAVATION FOR AREA WHERE FILL IS REQUIRED SHALL EXTEND 5' LATERALLY BEYOND S.A.S. 6. VERTICAL DATUM - ASSUMED T.O.B.H. = 100 7. SYSTEM IS NOT DESIGNED FOR GARBAGE GRINDER. 8. ALL PRE CAST UNITS ARE TO BE PLACED ON 6" MIN. CRUSHED STONE, MECHANICALLY COMPACTED. 9. MIN. PIPE SLOPE 1/8 IN/FT. 1/4 IN/FT PREFERRED. - 10. ALL CONSTRUCTION DETAILS ARE -10 CONFORM TO STATE OF MASS. ENVIRONMENTAL CODE (TITLE 5) AND LOCAL REGULATIONS. 11. ALL MANHOLE COVERS ARE TO BE WITHIN 6" OF FINISHED GRADE. 12. SEPTIC TANK TEES SHALL CONFORM TO MASS & LOCAL REGULATIONS. 13. ALL STONE IS TO BE DOUBLE WASHED ACCORDING TO MASS. & LOCAL REGULATIONS. 14. GROUND COVER OVER SYSTEM COMPONENTS SHALL NOT EXCEED 3'. 15. EXISTING LEACHING PIT, SHALL BE REMOVED ACCORDING TO LOCAL REGULATIONS. 16. LOCAL UPGRADE VARIANCE IS REQUESTED ACCORDING TO 310 C.M.R, 15.405(1) REDUCTION OF 5' SEP RtiAI17 BETWEEN BOTTOM OF SAS AND ADJUSTEDI E WATER ELEVATION TO 4', a Gz MICS. rG 4 -7h AUG 0 1 2002 HEALTH DEPT. YAPPROVAL 0 d/N NUMBER OF BEDROOMS: GARBAGE DISPOSAL UNIT: NONE TOTAL ESTIMATED FLOW: ( 110 GAL./BEDROOM/DAY X 4 BEDROOMS = 440 GPD) REQUIRED SEPTIC TANK CAPACITY= (200%) _ _ 880 GAL. ACTUAL TANK SIZE: 2 X 1000 GAL. LEACHING AREA REQUIRED: 1 SOIL CLASS - PERC RATE - ice_ MIN/IN. LTAR - 0.74_ GPD/FT 440 _ GPD / 0.74 GPD/S.F. _ _ 594.59 -SF USE - 595____ SF LEACHING CAPACITY: 4 FLOW DIFFUSERS WITH 3' OF STONE ON SIDES 4' STONE ON ENDS AND 1' STONE UNDER SIDES= [1QSL' x -'] _ _2Q(Z_ SF BOTTOM= [-10_' x _40 _'] _ __401L_ SF TOTAL AREA = --bDO - SF TOTAL CAPACITY = 600 SF *.74 GPD/SF = 444 GPD Date DESCRIPTION IlDrowniCheckedl R E V I S 1 0 N S SEPTIC SYSTEM UPGRADE DESIGN WALSH AT 101 CAPTAIN SMALL RD. IN YARMOUTH SCALE: 1" = 20' DATE: JUNE 4, 2002 LA BARGE ENGEIEERING & CONIRACMG,INC. 22MOSSHH,LRD. HARVICH, MA 02645 (508) 432.6360 DRAWN BY: SEM 0230 CHECKED BY: TAL SHEET 1 OF 1