Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 53 Lot /7 Zone of Contribution: In/Out Acreage /Z 3 74/ �'' Commercial: Residential: L/ Street: 02 g 6 C�v.,. P S-C Village: Floor Plan: #Bedrooms: a_ Owner: -s -I r t c. C p r re i r A Installer: A„ O u r c.. Address: Phone: 50 g - 4'77-- g 8 77 Phone: Builder: Engineer: Z1: �-- Cr L="-)CJ i N e e r i ry Address: Phone: I 0 - Phone: N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years t/- 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 1/1:10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ,✓ 11.Tank/leaching minimum 10 ft from property line Var.: / 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high _ oundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.` (JD wc1'et fag" \< 15. System not in top or subsoil(A,B horizons)or 5'removal 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1/"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 1 . 22. System adequately sized for its intended use i. 23.Minimum 6"stone or compacted below tank and dbox 't/-** 24. Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field \/ 26. Electrical permit for pump chamber/Separate meter for duplexes V 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed _ 29. Vent provided if leaching below 3 feet,under driveway/parking V. 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee,installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: __ 6 03 03