Loading...
HomeMy WebLinkAboutEngineer PlanT.O.F.EL.= 45.0'± PROVIDE EXTENSION RISER WITH COVER OVER INLET & FINISH GRADE OVER TANK EL.= FINISHED GRADE OUTLET TO WITHIN 6" OF F.G. @ FOUNDATION= 43.1'$ 42.5'± 21" MIN. ACCESS COVER (3 TYP.)- �9 MIN. 36" MAX. PROP. SCH. 40 + PVC SEWER, PROP. SCH. 40 PVC SEWER Mw.sLoEE@i% 6" 3" 2" DROP MIN.F. ', 14" 39.50' INLET TEE 39.75 48" OUTLET TEE TEES TO BE CENTERED GAS BAFFLE 11.7 OFFSET TO FND DIRECTLY UNDER RISERS 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE Q Q P POSED 1,500 GALLON CONCRETE SEPTIC TANK *CONTRACTOR TO vERI :ISTING LENGTH 10'-6" WIDTH 5'-8" DEPTH 5'-8" _ (Dimensions per ELEVATION PRIOR TO ANY WORK & S EI C .I ACME/Shorey) NOTIFY ENGINEER IF DIFFERENT. NOT TO SCALE NSP FINISH GRADE OVER D -BOX = 42.1' REMOVABLE WATER -TIGHT COVER OVER RISER TO WITHIN 6" OF FINISHED GRADE 5" DIA. OUTLET(S) 9„MIN. 4" INLET TEE 36"MAX . L - T+ PROVIDE WATERTIGHT 4" PVC IN FROMJOINTS (TYP.) SEPTIC TANK 4" PVC OUT TO LEACHING FACILITY 38.90' nnw. 6:( 38.73' 6" CRUSHED STONE OVER MECHANICALLY V/ COMPACTED BASE 5 OUTLET DISTRIB TON BOX TO BE INSTALLED ON A LEVEL STABLE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL. CROSS SECTION VIEW 5 NOT TO SCALE \ SO- 42 �Q� a r 00 4 LIN Ind \1 \ \ MAP 115 \\ O \\ LOT 42 2w a 26,250±S.F. o \ ,4 0` J\NE� PR N SEM MAP 115 w N 5/\\ \G GOM LOT 43 o g GAR .o0. Y SLE \t - / fib- ✓ l U.P. tj� dP PROPOSED TWO (2) 500 GALL H-20 o1NIW/ y \ 6„ \ LEACHING CHAMBERS w/ STON MAP 115 LOT 41 / j PROPOSED 4" SCH. 40 PVC VENT; tJ.P. / \ EXACT LOCATION PER OWNER - 10„ Z r PROP. H-20 "D -BOX" 43 ePt`O PROPOSED 1,500 EXISTING LEACHING PIT TO BE PUMPEi` / / a5� 'ol GALLON SEPTIC TANK FILLED wl CLEAN SAND &:ABANDON;- - ` // / / 3-s96ZlN°F / cns TOF=45.0'+ S Benchmark Nail in 24" Tree Elev. = 43.64' Approx. M.S.L. EXISTING 1,000 GALLON SEPTIC TANK TO BE ABANDONED PER 310 CMR 15.354 - Z-tltUKVUM 44 DWELLING i45 V� �6 SLAB=50 21' / A,1 1 NQ FL. EL. G QN ON�PFLo _ 51.5'± I a R NO�OO���O �N �Re � o0 m S66 p2 v ONO s)(\P ° �0- PROPOSED CLEAN-OUT FINISH GRADE OVER CHAMBERS= 422- 41.2' PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE GENERAL N , SLOPE @2%MIN. OVER SYSTEM 3/4" TO 1-1/2" DOUBLE WASHED 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION 4" SCHEDULE 40 PVC STONE TO CROWN OF PIPE METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL MIN SLOPE 1% 2" OF 1/8" TO 1/2" DOUBLE WASHED CODE AND ANY APPLICABLE LOCAL RULES. STONE OR GEOTEXTILE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. TOP OF SAS = 39.5Q' PLAjj LL 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL , 9" MIN. CHAMED 38.50 36" MAX. BREAKOUT EL= 39.001 INLETOF SYSTEM UNLESS OTHERWISE NOTED. GRADE 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 39.00' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 00 ' 0 0 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF L o O o THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. ooo 5. SLOPE ALL SOLID PIPE AT 1.0%MINIMUM. CF THIS SYSTEM IS NOTDESIGNED FOR A GARBAGE DISPOSAL. 2 0 CD 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK FILLING $ INSPECTION. SYSTEM IS = = 0 = oo NOT TO BEBACK FILLED EN SYSTEM I WITHOUT FIRS S NEARLY TOBTA OLETE BTAINING APPROVD READY AL FROM BOARD OF HEALTH AND DESIGN ENGINEER. 3 5' '� 8.5' (TYP) I 3-5' I 3.5'. I 4.83' 3.5' 8. ELEVATIONS BASED ON APPROXIMATE M.S.L. DATUM. SEE BENCHMARK ELEVATION AS VARIES (SEE PLAN) (TYP_) SHOWN ON PLAN. , GROUND WATER ELEV.= < 31.00' 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 36.50 VARIES (SEE PLAN) THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 2 - 500 GALLON CHAMBERS 5' MIN. 1 -888 -DIG -SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TYPICAL CHAMBER PROFILE h u/q� It yy��•� g CHAMBER END VIEW TO THE DESIGN ENGINEER. - H-20 C Ht o 3 E I3 E � ETAI Lam: 90. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. NOT TO SCALE 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING - PIT OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM • j' ,\'• o to TEST I-` I E-g� ATA APPROPRIATE AUTHORITY. PERC NO. N/A 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED JAN ME 10 ++ ..✓ , INSPECTOR: Phil Rene ud BOH "a�'TT1C3llt;, UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR GPP N 1 5 /q ' "' • " " ' + TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. :? +•. „ i (I EVALUATOR: Michael Pi entel, EIT, GSE 1ST �G CIf O p3 { •iI ! �� ' ` ' t. 6�-fin C.S.E. APPROVAL DATE�Oct. 27, 1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. 0-1,G(Fz j / 35 }* �1'•` t �`T'• •`t DATE: February 24, 2022 �3 e L 1 ) • ....., ' I; \ . ? 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE _l,. (5 i 11 �. , \* TEST PIT #: 1 MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. / - LOCI I S (', • •' '•' REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, O ` ,f ELEV TOP = 42.00' QL " f . , r' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). • ";• rI r , ELEV WATER = < 31.00' • I ,, 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN / 'o i. + ,;, / fi I ., PERC RATE _ < 2 min./inch SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. / 3) . j 5 f* •/ ' ,I DEPTH OF PERC = 36" - 54" 16. PROPOSED PROJECT IS LOCATED WITHIN: ASSESSOR'S MAP 115 LOT 42 (6 TEXTURAL CLASS: I /J� S _, + f OWNER OF RECORD: ELAINE ELLIOTT (7 * ; 'I' s_ •'f • ' 'f « • , / . +/, __ ____ _.__ ADDRESS: 90 SHAKER HOUSE ROAD 17 + ` + • + «+ �`` 0" 42 00' YARMOUTH PORT, MA 02675 C6 M A4 .� t _._. . 1• ��. A ZONE 11'fis . 32" 2 ( Y I n . 2nd STORY ` ` I Perc (NO FND) �r _ � `�', � ��`3 ' c ,�,r<p t'` I 50., 3 -SEASON DECK nber S 1 og > EXITIING --- $ +' �s,r� 2 -BEDROOM ' _!i,+ ._ r\ITI k C DWELLING I LOCUS PLAN PROPOSED SEPTIC DIMENSIONS & SETBACKS SCALE: 1" = 10' SWING -TIES DESCRIPTION HC -1 HC -2 SEPTIC COVER IN (1) 13.2' 17.8' SEPTIC COVER OUT (2) 21.2' 14.8' CORNER OF STONE (3) 29.3' 25.1' CORNER OF STONE (4) 38.1' 40.4' CORNER OF STONE (5) 27.7' 43.2' CORNER OF STONE (6) 16.5' 32.6 CORNER OF STONE (7) 19.0' 25.7' SCALE: 1" = 1000' - DESIGN DATA NUMBER OF BEDROOMS (EXISTING NUMBER OF BEDROOMS (DESIGN) 2 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 220 GAUDAY DESIGN FLOW x 200 = 440 GAUDAY USE PROPOSED 1,500 GALLON SEPTIC TANK INSTALL 2 - 500 GAL. CHAMBERS w/ STONE SIDEWALL CAPACITY (PERIMETER) (2' HIGH) (0.74 GPD/S.F.) = GAUDAY (71.66') (2') ( 0.74 GPD/8.F.) = 106.1 GAL/DAY BOTTOM CAPACITY (FOOTPRINTAREA) (0.74 GPD/S.F.) = GAUDAY (283.9 S.F.) (0.74 GPD/S.F.) = 210.1 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 2 TOTAL LEACHING AREA 427 SQ.FT. TOTAL LEACHING CAPACITY 316.2 GAL./DAY NOTES. 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA 3.) PROPERTY IS LOCATED WITHIN A DEP APPROVED ZONE IL 4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. RESERVED FOR BOARD OF HEALTH USE Fill Loamy Sand 10Yr 4/1 Fine Sand 1 OYr 5/8 i Med. to Coarse Sand 2.5Y 6/61 41.50' i FEMA FLOOD ZONE X j COMMUNITY PANEL # 25001CO578J 41-00'17. DEED REFERENCES: 1.) BOOK 19567, PAGE 319 2.) BOOK 29826, PAGE 212 18. PLAN REFERENCES: 1.) PLAN BOOK 187, PAGE 149 2.) PLAN BOOK 323, PAGE 34 39.33' 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY 37.83' FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 21. OWNER/ APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. Yarmoat6 Health ]lepart>meat APPRgVW 132" 31.00' No Mottling, Standing or Weeping Observed I ' l�Ir) 50xO' EXISTING SPOT GRADE - - 50 - - EXISTING CONTOUR - 150 PROPOSED CONTOUR F-50-1 PROPOSED SPOT GRADE GAS EXISTING GAS LINE 0/H/W - EXISTING OVERHEAD UTILITIES - W W --- EXISTING WATER LINE TEST PIT LOCATION O O O PROPOSED 1,500 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE APR 13 2022 13 PROPOSED H-20 DISTRIBUTION BOX MO PROPOSED 500 GALLON H-20 LEACHING CHAMBER HEALTH DEPT. 1 4-6-22 REV. DATE SN OFSS9C 02 y�N JOHN L. o CHURCHILL JR. m v N0-48066 0: T ao 9 r I �ZN OF &ASS _..... IIi JOHN L.�N I CHURCHILL JR. '•� CIVIL h No. 41.807 i i MCP JLC Down -size SAS to be under 330 gpd per health dep't BY APP'D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR: ROBERT B. OUR CO., INC. LOCATED AT 90 SHAKER HOUSE ROAD YARMOUTH PORT, MA 02675 SCALE: 1 INCH = 20 FT. DATE: MARCH 9, 2022 0 10 20 40 80 FEET PREPARED BY: JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 _ Drawn By MCP Designed By MCP , Checked By: JLC JOB No. 6118