HomeMy WebLinkAbout Review Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 37 Lr, f Lot ,7� 7 Zone of Contribution: In Out Acreage/� Q,sB 61// n Commercial: esidential: i/ ' Street: I4 y 2 Village: Floor Plan: - ✓ #Bedrooms: a Owner: /cc?re no /-jy N N Installer: CL c e 4/ me re L.&:11-.Address: _ Phone: .6-0k '3 q e - .o1/6 Phone: Builder: Engineer: bra N L'''Us/ft,e e.r;rvc.\ Address: Phone: $-'0 2 4Y3�- a g 78 Phone: N YES NO 1.Required#of copies received 2. Date of soils exam and percolation test not older than 2 years V 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: V 6.Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation, deck Var.: $1' 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: V._ 12. System meets all other setback requirements Var.: _ ✓ 13.Uses adjustment for maximum high groundwater Var.: V 14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: - 15. System not in top or subsoil(A,B horizons)or 5'removal _ ! 16.Proposed contours are suitable - V 17. System meets slope requirements-min. 1/8", 'A"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper,gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel ✓' 21.No garbage disposal 22. System adequately sized for its intended use ✓ 23.Minimum 6"stone or compacted below tank and dbox ;/� 24. Manhole covers within 6"of grade,pump chamber cover to grade t// 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes 1../27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber ✓ 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓ 33.H-20 loading is subject to vehicular traffic,groundwater ✓ 34.Title V Application and permit fee,installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house / • 36.Deed Restriction required max. #bedrooms: max. flow: gpd f 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by Gjr-Au. (�t'n �� v of o: