HomeMy WebLinkAbout Review Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 37 Lr, f
Lot
,7� 7 Zone of Contribution: In Out Acreage/� Q,sB
61// n Commercial: esidential: i/ '
Street: I4 y 2
Village: Floor Plan: - ✓ #Bedrooms: a
Owner: /cc?re no /-jy N N Installer: CL c e 4/ me re L.&:11-.Address: _ Phone: .6-0k '3 q e - .o1/6
Phone:
Builder: Engineer: bra N L'''Us/ft,e e.r;rvc.\
Address: Phone: $-'0 2 4Y3�- a g 78
Phone:
N YES NO
1.Required#of copies received
2. Date of soils exam and percolation test not older than 2 years V
3.4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: V
6.Benchmark indicated and shown-NGVD if near wetlands V
7. Septic tank minimum 10 ft from foundation, deck Var.: $1'
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11.Tank/leaching minimum 10 ft from property line Var.: V._
12. System meets all other setback requirements Var.: _ ✓
13.Uses adjustment for maximum high groundwater Var.: V
14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: -
15. System not in top or subsoil(A,B horizons)or 5'removal _ !
16.Proposed contours are suitable -
V
17. System meets slope requirements-min. 1/8", 'A"preferred
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper,gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel ✓'
21.No garbage disposal
22. System adequately sized for its intended use ✓
23.Minimum 6"stone or compacted below tank and dbox ;/�
24. Manhole covers within 6"of grade,pump chamber cover to grade t//
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes 1../27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber ✓
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓
33.H-20 loading is subject to vehicular traffic,groundwater ✓
34.Title V Application and permit fee,installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house / •
36.Deed Restriction required max. #bedrooms: max. flow: gpd f
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by Gjr-Au. (�t'n �� v of o: