Loading...
HomeMy WebLinkAboutEngineer PlanWells not shown exceed 150' from the proposed SAS BENCHMARK EL. 23.7 TOP OF BLOCK FOUNDATION SILL UNDER BULKHEAD DOOR DATUM NAVD-88 NOTE: GAS LINE NOT MARKED BY DIGSAFE. METER LOCATED AT FRONT OF DWELLING. Oa31k 23 — ,�, 23 2 3. 3 �� . 1 , r 23,1 i 23. CV '.5 2� 0 DIN/NG BATH REONO0M SUN- ROOM KITCHEN AREA ROOM / HALL LIVING \ 0.8 �aP v FIRST FLOOR PLAN ROOM BEDROOM NOT TO SCALE UNfIN/SHfD BASEMENT S SO•: '3.4� 1�10 � °'<�/ Al. e 23.2, / 3)40' \� 22, t / ®� 2 hog 23.21 ee -C/ 5F °> / r 23.4 `° C/0 Birch /� *n_� 23.2 i22j6,j3.1 v q6 23.2/229 e � 6I 23.9 d � a � X229 �V io 23.6 I %/ Oak' ,�. 1 �� � CO.9 � \ WOODED AREA i 22.4 _ 23.6 Sib .°A' LOT 129 600, 14,058 SFt Ay 0.32 Act w \ 0 2022 Moran Engineering Associates, LLC ?/ 22.6 22.6 4 20.8 ® MAG SET 20.6 SEWAGE DISPOSAL SYSTEM DETAIL /' = 20' DISTRIBUTION BOX LPROP. SEPTIC TANK INF/L TRA TOR /M-1530 —PROPOSED LEACHING AREA CUL TEC RECHARGER /8OHD 32.65' L X /l. 00' W - FIELD SET ROWS P APART INSTALL 3-/NPSECTION PORTS Assessors' ID: 39/279 Deed: Book 32,275, Page 85 Plan: Book 155, Page 93, Lot 129 -EGEND Existing Building — Edge of Driveway 23 Existing Contour 23.2 Existing Spot Elevation m a Existing Fence Line TH# ® Septic Test Hole Existing Cesspool Yarmouth Health Department 0 0 20 40 .0 S �Si'aa� `'"C) "MA. �=®RAN ENGINEERING ASSOC.9 �y z�-ooh .�� RICHARD ' Uob 508-432-2878 941 ROUTE 28, HARWIC JU z .SEPTIC SYSTEM DESIGN PLAN Prepared For: Kathleen Flynn TRP-, � 25 SCHOLL AVENUE WEST YARM PROJECT.- 22-006 SHEET 1 of 2 DATE: Date v 1. PROVIDE A 4" PVC CLEAN -WT CAP (C/O) To SEP TI C TANK GRADE BETWEEN DWELUNG AND SEPTIC TANK BN INSTALL IRRIGATION CONTROL BOX COMER OYER C/0. INFILTRATOR IM -1530 TOP BE DEAN -OUT FOUNDATION EL.23.0 f ^^VERS (2) TO BE wTHIN 6" OF GRADE W. 15', E: 25' + SLOPE: 0.02 MINIMUM SEWER NOTES 1. The building sewer shall be laid on a firmly comoacTeO Dose - KLwynnu. 2. A 4" building sewer is laid at a slope of not less than 0.01' (1/8 inch per foot). A slope of 0.02 (1/4 inch per foot) is preferable. 3. The sewer shall be laid on a continuous grade ELEV. 23.20 22.70 20.53 13.03 BC MIN. 9" COVER W: EL21.70 s =< aoz M'. E: EL.22.00 EL.21, 20 BGastnc r GST NtON W. 15', E: 25' + SLOPE: 0.02 MINIMUM SEWER NOTES 1. The building sewer shall be laid on a firmly comoacTeO Dose - KLwynnu. 2. A 4" building sewer is laid at a slope of not less than 0.01' (1/8 inch per foot). A slope of 0.02 (1/4 inch per foot) is preferable. 3. The sewer shall be laid on a continuous grade ELEV. 23.20 22.70 20.53 13.03 SEPTIC TANK NOTES 1. Extend inlet tee 10" below flow line; extend outlet tee 14" below flow line. 2. Provide (2) 24" diameter access ports, over the inlet and outlet accesses, with watertight risers to within 6" of finish grade. 3. Septic tank minimum burial depth 9" and maximum burial depth of 48". DEEP HOLE LOGS nFFP OBSERVATION HOLE If 1 TEST BY: RICK JUDD DATE: 2/9/2022 From COLOR REDOX S7RUC7URE SLAare HOA. TEXTURE (MUNSELL) FEATURES CONSISTENCY, OTHER 6" AE Loamy Sand 10 YR 5/2 NO I Granular 32" Bw Loamy Medium Sand 7.5YR 4/4 NO Massive, Very Friable 122" C Fine Sand 10YR 614 No Loose, Single Grain BOTTOM OF PERC.: 50". 24 -GALLONS OF WATER IN 06:00 -MINUTES (<6" REMAINING). PERC. RATE = <2-MIN./INCH. CLASS I SOIL. LOADING RATE = 0.74 GPD/SF WITNESS: PHILIP RENAUD, YARMOUTH HEALTH DEPARTMENT 0 Moran Engineering Associates, LLC "D" BOX COVER WITHIN 6" OF GRADE ACCESS PORT MIN. 9" COVER MIN. 36' COVER 00 r vvc SCH 40 EL.20.05 11' t LEVEL STABLE BASE DISTRIBUTION BOX NOTES EL.19.85 B', 4'. 8'f 1. When s tem L dosed or slo a of inlet a exceeds 008 ft install inlet tee cut-off one inch above outlet invert. 2. Install outlet pipes level 2 feet minimum. 3. Provide a minimum sump of 6" below outlet invert. 4. Install access port over "D" Box with precast concrete or equivalent watertight riser within 6" minimum of final grade. DESIGN 1. REQUIRED FLOW: *2 BEDROOMS X 110 GPD/B.R.= 330 GPD *3 BEDROOM MIN. DESIGN FLOW PER TITLE 5 2. SEPTIC TANK CAPACITY: 330 GPD X 2 = 660 GPD USE: 1500 -GALLON SEPTIC TANK INFILTRATOR IM -1530 POLY. TANK OR CONCRETE SEPTIC TANK. NO OTHER SUBSTITUTIONS. 3. LEACH FACILITY DESIGN: (5 CHAMBERS x 6.33'/ CHAMBER) + 1.0' LENGTH ADJUSTMENT = 32.65 LF / ROW 32.65 LF x *5.0 SF/LF = 163.25 SF 163.25 SF x 3 ROWS = 489.75 SF 489.75 SF x 0.74 GPD/SF = 362.4 GPD 362 GPD PROVIDED > 330 GPD REQUIRED *PER MASS. DEP APPROVAL FOR GENERAL USE (3/21/16). USE: (3) ROWS OF 5-CULTEC RECHARGER 18OHD CHAMBERS. SET ROWS 1' APART. COVER CHAMBERS WITH CULTEC 410 FILTER FABRIC AND BACKFILL TO TOP OF CULTECS WITH A CLEAN SAND. INSTALL 3 -INSPECTION PORTS. CONSTRUCTION NOTES 1. CONTACT OFFICE (508) 432-2878 A MINIMUM OF 2 - DAYS PRIOR TO START OF PROJECT. FAILURE TO NOTIFY OFFICE MAY CAUSE DELAY IN INSPECTION PROCESS. 2. CONTRACTOR IS REQUIRED TO BE A CERTIFIED CULTEC INSTALLER. 3. INSTALLER IF TO VERIFY SEWER LINE PIPE INVERTS PRIOR TO PLACEMENT OF COMPONENTS. 4. PUMP AND FILL ALL CESSPOOLS- INSPECTION REQUIRED. 5. A SOIL INSPECTION IS REQUIRED PRIOR TO PLACEMENT OF LEACH COMPONENTS. 6. COMPONENT ACCESS RISERS ARE TO BE INSTALLED ON SEPTIC TANK, DISTRIBUTION BOX AND LEACH AREA (3). 7. CULTER 410 FILTER FABRIC IS TO BE USE TO COVER CHAMBERS PRIOR TO PLACEMENT OF CLEAN SAND. 8. A FINAL INSPECTION IS REQUIRED BY MORAN ENG. & THE YARMOUTH HEALTH DEPT. PRIOR TO COVERING SYSTEM COMPONENTS. 9. LOAM AND SEED ALL LAWN IMPACT ARES. RAKE AND GRADE ALL NATURAL AREAS WITH ON SITE MATERIALS. ALL LANDSCAPE DETAILS SHALL BE BETWEEN THE PROPERTY OWNER AND INSTALLER. LEACH FACILITY CULIEC RECHARGER 180HD Control Box 4' or 6' PVC PULL CAP, END CAP, END PLUG OR CLEANOUT. C of 6' SCH. 40 PVC OR MIN. 9" COVER 3 - INSPECTION PORTS MAX 36" COVER CULTEC 410 FILTER FABRIC 1 EL.20.31t 14" 20.5" EL.19.77 ' INVERT EL.18.60 6.33' EACH UNIT (INSTALLED) LENGTH ADJUSTMENT 1.00' 32.65' LENGTH INSTALLED 5,57' EL.13.03 NO WATER ENCOUNTERED AT BOTTOM TEST HOLE 1. NOTES FOR CULTEC 1.) Must be a Cert.Cultec Installer. 2.) Cultec No. 410 Filter Fabric or equal approved by Cultec required. GENERAL NOTES 1.) ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE W/TTPLE 5 OF THE SANITARY CODE & ANY APPLICABLE REGULATIONS. 2.) PRIOR TO BACK FILLING THE INSTALLATION, THE DESIGNER & HEALTH AGENT SHALL BE NOTIFIED FOR INSPECTION. 3.) ANY ALTERATIONS OF THIS DESIGN MUST BE APPROVED BY THE DESIGNER & BOARD OF HEALTH, IN WRI'T'ING. 4.) SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER. 5.) THE INSTALLER IS TO VERIFY THE LOCATION(S) OF UTILITIES, CESSPOOL(S) AND SEWER INVERTS PRIOR TO CONSTRUCTION. 6.) ALL UNSUITABLE MATERIAL WITHIN 5 FT. IN ALL DIRECTIONS FROM THE SOIL ABSORPTION SYSTEM SHALL BE REMOVED & REPLACED W/CLEAN, COARSE SAND. 7.) ALL FILL MATERIAL UTILIZED FOR THE SOIL ABSORPTION SYSTEM SHALL BE CLEAN, COARSE SAND FREE FROM DELETERIOUS MATERIAL AND SHALL HAVE A PERCOLATION RATE OF LESS THAT 2 MIN./IN. BEFORE & AFTER PLACEMENT. 8.) EXISTING CESSPOOLS) TO BE PUMPED AND BACK FILLED PER TITLE 5 ABANDONMENT PROCEDURES. 9.) DURING INSTALLATION, THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A SAFE EXCAVATION AREA. lOJ GROUND COVER OVER SEPTIC SYSTEM COMPONENTS SHALL NOT EXCEED 36". 11.) ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL NOT BE LESS THEN 0.01 FT/Fr. 12.) WHEREVER SEPTIC LINES CROSS WATER SERVICE LINES OR WHEN WATER SERVICE LINES COME WITHIN IP OF THE PROPOSED S.A.S.- PIPES SHALL BE CLASS 150 PRESSURE PIPE & SHOULD BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS. COORDINATE WITH LOCAL WATER DEPARTMENT, 13.) PLACE MAGNETIC MARKING TAPE OVER ALL COMPONENTS. RAN EN OC.. LLC -432-2878 941 ROUTE 28, HARV SEPTIC SYSTEM DESIGN PLAN Prepared For: Kathleen Flyr 25 SCHOLL AVENUE WL -'I YAKI PROJECT.- 22-006 1 SHEET 2 of 2 1 DATE. - ft MIN. 9" COVER MIN, l6' COYER CESS W.) 24° EL.21.87t t24'WBING 1L<INSTAL E BAFFLE LEVEL STABLE BASE 14.7' SEPTIC TANK NOTES 1. Extend inlet tee 10" below flow line; extend outlet tee 14" below flow line. 2. Provide (2) 24" diameter access ports, over the inlet and outlet accesses, with watertight risers to within 6" of finish grade. 3. Septic tank minimum burial depth 9" and maximum burial depth of 48". DEEP HOLE LOGS nFFP OBSERVATION HOLE If 1 TEST BY: RICK JUDD DATE: 2/9/2022 From COLOR REDOX S7RUC7URE SLAare HOA. TEXTURE (MUNSELL) FEATURES CONSISTENCY, OTHER 6" AE Loamy Sand 10 YR 5/2 NO I Granular 32" Bw Loamy Medium Sand 7.5YR 4/4 NO Massive, Very Friable 122" C Fine Sand 10YR 614 No Loose, Single Grain BOTTOM OF PERC.: 50". 24 -GALLONS OF WATER IN 06:00 -MINUTES (<6" REMAINING). PERC. RATE = <2-MIN./INCH. CLASS I SOIL. LOADING RATE = 0.74 GPD/SF WITNESS: PHILIP RENAUD, YARMOUTH HEALTH DEPARTMENT 0 Moran Engineering Associates, LLC "D" BOX COVER WITHIN 6" OF GRADE ACCESS PORT MIN. 9" COVER MIN. 36' COVER 00 r vvc SCH 40 EL.20.05 11' t LEVEL STABLE BASE DISTRIBUTION BOX NOTES EL.19.85 B', 4'. 8'f 1. When s tem L dosed or slo a of inlet a exceeds 008 ft install inlet tee cut-off one inch above outlet invert. 2. Install outlet pipes level 2 feet minimum. 3. Provide a minimum sump of 6" below outlet invert. 4. Install access port over "D" Box with precast concrete or equivalent watertight riser within 6" minimum of final grade. DESIGN 1. REQUIRED FLOW: *2 BEDROOMS X 110 GPD/B.R.= 330 GPD *3 BEDROOM MIN. DESIGN FLOW PER TITLE 5 2. SEPTIC TANK CAPACITY: 330 GPD X 2 = 660 GPD USE: 1500 -GALLON SEPTIC TANK INFILTRATOR IM -1530 POLY. TANK OR CONCRETE SEPTIC TANK. NO OTHER SUBSTITUTIONS. 3. LEACH FACILITY DESIGN: (5 CHAMBERS x 6.33'/ CHAMBER) + 1.0' LENGTH ADJUSTMENT = 32.65 LF / ROW 32.65 LF x *5.0 SF/LF = 163.25 SF 163.25 SF x 3 ROWS = 489.75 SF 489.75 SF x 0.74 GPD/SF = 362.4 GPD 362 GPD PROVIDED > 330 GPD REQUIRED *PER MASS. DEP APPROVAL FOR GENERAL USE (3/21/16). USE: (3) ROWS OF 5-CULTEC RECHARGER 18OHD CHAMBERS. SET ROWS 1' APART. COVER CHAMBERS WITH CULTEC 410 FILTER FABRIC AND BACKFILL TO TOP OF CULTECS WITH A CLEAN SAND. INSTALL 3 -INSPECTION PORTS. CONSTRUCTION NOTES 1. CONTACT OFFICE (508) 432-2878 A MINIMUM OF 2 - DAYS PRIOR TO START OF PROJECT. FAILURE TO NOTIFY OFFICE MAY CAUSE DELAY IN INSPECTION PROCESS. 2. CONTRACTOR IS REQUIRED TO BE A CERTIFIED CULTEC INSTALLER. 3. INSTALLER IF TO VERIFY SEWER LINE PIPE INVERTS PRIOR TO PLACEMENT OF COMPONENTS. 4. PUMP AND FILL ALL CESSPOOLS- INSPECTION REQUIRED. 5. A SOIL INSPECTION IS REQUIRED PRIOR TO PLACEMENT OF LEACH COMPONENTS. 6. COMPONENT ACCESS RISERS ARE TO BE INSTALLED ON SEPTIC TANK, DISTRIBUTION BOX AND LEACH AREA (3). 7. CULTER 410 FILTER FABRIC IS TO BE USE TO COVER CHAMBERS PRIOR TO PLACEMENT OF CLEAN SAND. 8. A FINAL INSPECTION IS REQUIRED BY MORAN ENG. & THE YARMOUTH HEALTH DEPT. PRIOR TO COVERING SYSTEM COMPONENTS. 9. LOAM AND SEED ALL LAWN IMPACT ARES. RAKE AND GRADE ALL NATURAL AREAS WITH ON SITE MATERIALS. ALL LANDSCAPE DETAILS SHALL BE BETWEEN THE PROPERTY OWNER AND INSTALLER. LEACH FACILITY CULIEC RECHARGER 180HD Control Box 4' or 6' PVC PULL CAP, END CAP, END PLUG OR CLEANOUT. C of 6' SCH. 40 PVC OR MIN. 9" COVER 3 - INSPECTION PORTS MAX 36" COVER CULTEC 410 FILTER FABRIC 1 EL.20.31t 14" 20.5" EL.19.77 ' INVERT EL.18.60 6.33' EACH UNIT (INSTALLED) LENGTH ADJUSTMENT 1.00' 32.65' LENGTH INSTALLED 5,57' EL.13.03 NO WATER ENCOUNTERED AT BOTTOM TEST HOLE 1. NOTES FOR CULTEC 1.) Must be a Cert.Cultec Installer. 2.) Cultec No. 410 Filter Fabric or equal approved by Cultec required. GENERAL NOTES 1.) ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE W/TTPLE 5 OF THE SANITARY CODE & ANY APPLICABLE REGULATIONS. 2.) PRIOR TO BACK FILLING THE INSTALLATION, THE DESIGNER & HEALTH AGENT SHALL BE NOTIFIED FOR INSPECTION. 3.) ANY ALTERATIONS OF THIS DESIGN MUST BE APPROVED BY THE DESIGNER & BOARD OF HEALTH, IN WRI'T'ING. 4.) SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER. 5.) THE INSTALLER IS TO VERIFY THE LOCATION(S) OF UTILITIES, CESSPOOL(S) AND SEWER INVERTS PRIOR TO CONSTRUCTION. 6.) ALL UNSUITABLE MATERIAL WITHIN 5 FT. IN ALL DIRECTIONS FROM THE SOIL ABSORPTION SYSTEM SHALL BE REMOVED & REPLACED W/CLEAN, COARSE SAND. 7.) ALL FILL MATERIAL UTILIZED FOR THE SOIL ABSORPTION SYSTEM SHALL BE CLEAN, COARSE SAND FREE FROM DELETERIOUS MATERIAL AND SHALL HAVE A PERCOLATION RATE OF LESS THAT 2 MIN./IN. BEFORE & AFTER PLACEMENT. 8.) EXISTING CESSPOOLS) TO BE PUMPED AND BACK FILLED PER TITLE 5 ABANDONMENT PROCEDURES. 9.) DURING INSTALLATION, THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A SAFE EXCAVATION AREA. lOJ GROUND COVER OVER SEPTIC SYSTEM COMPONENTS SHALL NOT EXCEED 36". 11.) ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL NOT BE LESS THEN 0.01 FT/Fr. 12.) WHEREVER SEPTIC LINES CROSS WATER SERVICE LINES OR WHEN WATER SERVICE LINES COME WITHIN IP OF THE PROPOSED S.A.S.- PIPES SHALL BE CLASS 150 PRESSURE PIPE & SHOULD BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS. COORDINATE WITH LOCAL WATER DEPARTMENT, 13.) PLACE MAGNETIC MARKING TAPE OVER ALL COMPONENTS. RAN EN OC.. LLC -432-2878 941 ROUTE 28, HARV SEPTIC SYSTEM DESIGN PLAN Prepared For: Kathleen Flyr 25 SCHOLL AVENUE WL -'I YAKI PROJECT.- 22-006 1 SHEET 2 of 2 1 DATE. - ft