HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. /H /. Lot 2' Zone of Contribution: In Out Acreage I I,4i..:7 s F
Commercial: Residential: 1.----
Street:
Street: 3 4..)7 (-- s& -c
Village: Floor Plan: #Bedrooms: q
Owner: o' icE c_ r Installer: 72:::,t-v) (.___A-C-.4) v !-
Address: _ Phone:
Phone:
Builder: Engineer: 7 '-t 1--,c
Address: Phone:
Phone:
N/A YES/ NO
1.Required#of copies received ✓/
2.Date of soils exam and percolation test not older than 2 years _ ✓✓✓
3.4-5 ft of naturally occurring pervious material,above water table I /
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: ,/
6.Benchmark indicated and shown-NGVD if near wetlands /
7. Septic tank minimum 10 ft from foundation,deck Var.: &le t -,- ✓
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: /4).-7 ru r7 /l.G nrwet 1.---
9.
9.Leaching minimum 100 ft from wetlands Var.: .✓
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓
11.Tank/leaching minimum 10 ft from property line Var.: S ' 5 rt-s ,/
12. System meets all other setback requirements Var.: ,/
13.Uses adjustment for maximum high groundwater Var.: ✓
- 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: %/
15. System not in top or subsoil(A,B horizons)or 5'removal
16.Proposed contours are suitable ,/
17. System meets slope requirements-min. 1/8", 1/4"preferred /
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee ✓ *I 2
20. Sewage is under 10,000 gpd for parcel /
21.No garbage disposal V
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox ✓ / (v
24.Manhole covers within 6"of grade,pump chamber cover to grade ✓
25. Inspection port on plastic chambers/leach field /
26.Electrical permit for pump chamber/Separate meter for duplexes /
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size /
28. Septic tank/pump chamber to be factory waterproofed /
29.Vent provided if leaching below 3 feet,under driveway/parking /
30.Buoyancy calculations for tank/pump chamber ,/
31.Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater 111V
34.Title V Application and permit fee,installer signature
35.Foundation footing min.2 feet above adjusted ground water for new house _ /
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37.Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 3(
60301
7
ki4--7-LS ye d9---f iA.--)