HomeMy WebLinkAboutEngineer PlanHIGGINS VEA
OLEGEND ROWEL �
NCOMMON
`
- -102--- EXISTING CONTOUR
\\ ^uJ%�/
1 BENCHMARK-2
x 100,98 EXISTING SPOT GRADE
-W- EXISTING WATER SERVICE
S\MEINTRE
o - 998 COR./BOTT.S7EP
4-
s /
„.
--G- EXISTING SERVICE
y 19975 f 9995 EL.= 100.24
GAS
-O.H.W.- OVERHEAD WIRES
EXISTING SEPTIC TANK
70P OF TANK, EL. = saso BENCHMARK-1
INv (OUT) 9715t COR./EULKHEAD
COITUS `
TEST PIT
s, 9939 EL. =100.0
BENCHMARK
EXISTING CESSPOOLx 0,0
\
(per record location).
\)
TO BE PUMPED & REMOVED 99.57 99 �.}.
(SEE ALSO, NOTE 17) 99.8
/ Oi i
J ,
100.1K x 99,82
1 s
DECK
u> STO�/� 100.77
m : RIVEWAY ° !L, x0.08 S
999A 6829'
S
i
[BH]
o
x 9913 x 924
F�
I 1 22 39"
LOCUS MAP
h 9966... 99.2 �i 133 E
� �\ l
BEDROOM BATH KIT./DINING
m OUSE(#68) x 98.82 1 1
O t0 \ TO.. =101.0.*, ' r
r
�^ HALL
,� 0 x 97.55
98. 1
d
Y 1
N ,� BM_2 8 Qob�
til 100,2a l0000 x 98.89 )
Q) I
�.19
BEDROOM LIVING ROOM
EXISTING SHED 1 S' 9897 9941 DECK 9939 /
TO BE RELOCATED ? � ..• „ ;, t f t I
£ + 97.64
•,
�
TP 96.82
x 98.45
' x 9836 97.95
CZ FLOOR PLAN
_6)$-x
PROPOSED S.A.S. t'
�0 652
Ver
NO
2-500 GALLON CHAMBERS .� '' �'"- - --" .96,66 I
x
l-
SURROUNDED W/4' STONE +8.21 19729
O 4
x 97.32 1 + I�
�VLA1- 86.23
p
11 N 82°3
160.716„ W
\
„-- -
- I \
�'- - 75' BUFFER`' �� _ ! 9673 \\ �\
r
r+'-'--_ _.,,, 96.93 ..
WOODED
`1 LOT C--q&
� o
_-- two°°
189.94' ~ 0 34,202±S.F.
+ 95.61 9 4b3
SPIyKE�4-----94-42
N 82°30'26"
RECEIVED
Il x9 33 - �yJ 9TACK 56K
��
+93.13 ~`•`9eb
APR 06 2022
92.23
GENERAL NOTES:
�c�-L +9234 +9375
of yggJ9� N s$�I1'
HEALTH DEPT.
P\�� ~
gG ` -`'--
yGs
1 ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE L
9' ly `
CAL o� PETER T. -90`"� ~''
BOARD OF HEALTH AND THE DESIGN ENGINEER.
McENTEE �, '86------
OWNER OF RECORD
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
o� CIVIL "' "- `, e� "' ��-..,
~"f
ANDERSON, JOSHUA J
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
_
No. 35109 � -�
~�,�
ANDERSON, ERICA M
LOCAL RULES AND REGULATIONS.
O Q s�sa€�-#
PRIOR c'st
68 HIGGINS CROWELL RD
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED
WF-1 APPROVED WF-
WEST YARMOUTH, MA 02673
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH
ND THE 66.52 � 6 6
Z-
DESIGN ENGINEER.
Z \� PLAN REFERENCE
�•� D8Y0 1) CERTIFIED PLOT
PLAN BY DOWN CAPE ENGINEERING,
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
aro@ wFTs
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE
DESIGN YARMOUTH PORT, MA, DATED 9/18/89
MAP ID: 39-36
ENGINEER BEFORE CONSTRUCTION CONTINUES.
2) PLAN BOOK 455
PAGE 95, LOT 4
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING PROPOSED SEPTIC SYSTEM UPGRADE PLAN
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILUIRE
OF 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD
p
OF IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND 6$ HIGGINS CROWELL RD, W. YARMOUTH, MA
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
12. AREAS REQUIRING STRIPOUT.OF UNSUITABLE MATERIALS SHALL BE Prepared for: Joshua Anderson, 68 Higgins Crowell Rd, W, Yarmouth, MA 02673
8. THERE ARE NO WELLS WITHIN. 100' OF THE PROPOSED S.A.:.
INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL.. Engineering by:
SCALE DRAWN JOB. NO.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTOR
D AS 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND Engineering Works, Inc.
1"=30' P.T.M. 158-22
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHER
SE IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. 12 West Crossfield Road, Forestdale, MA 02644
DATE CHECKED SHEET NO.
DIRECTED BY THE APPROVING AUTHORITIES.
13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND (508) 477-5313
4/5/22 P.T.M. 1 Of 2
"Y
SEPTIC TANK
INSTALL RISERS & COVERS OVER INLET &
OUTLET AND SET TO 6" OF FINISH GRADE
T.O.F=101.0±
-F.G. EL.=100.0±
EXISTING
F.G. EL.=99.5±
4e" LIQUID
LEVEL
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION.
2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE
ON A MECHANICALLY COMPACTED STABLE. BASE OR
SIX INCH AGGREGATE BASE, AS SPECIFIED IN 310
CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
DESIGN CRITERIA
STALL RISER & COVER
T TO 6" OF GRADE
F.G. EL.=99.0±
L = 18' _ 1
® S=1% (MIN.) ®LS=1%MIN.)
4"SCH40 PVC 4'SCH40 PVC
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SHALL NOT BE AT, OR BELOW, EL.=96.0
FOR A DISTANCE OF 15' FROM THE EDGE
OF THE PROPOSED S.A.S.
PROPOSED S.A.S.
INSTALL RISER & COVER OVER ONE CHAMBER AND
SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT
r F.G. EL.=98.7±
MAINTAIN 2% SLOPE OVER S.A.S.
INV. =95 .�87-j PROPOSE D` � 4.8' 4'
INV.=95.70
IV.=97.15± EFFECTIVE WIDTH
VERIFY 3 OUTLETS
INV.=95.50
ADD INLET TEE 2-500 GALLON LEACHING CHAMBERS
SURROUNDED WITH 4' OF STONE
1 H-10 RATED
TOP CONC. ELEV.=96.3± -
BREAKOUT ELEV.=96.00-
INV. ELEV.=95.50 -
BOTTOM ELEV.=93.50-
4' DF NATURALLY OCCURRING
PERVIOUS MATERIAL
ABOVE GROUNDWATER
NO GROUNDWATER, EL.=87.5 -
0
NUMBER OF BEDROOMS: 2
SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 G
DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 330 GPD
DESIGN FLOW: 330 GPD
GARBAGE GRINDER: NO -not allowed with design
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
.✓4 uru ar
EXISTING SEPTIC TANK: 1000 GALLON CAPACITY
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-20 RATED
USE 2-500 GALLON LEACHING CHAMBERS IN SERIES
SURROUNDED WITH 4' OF STONE
SIDEWALL AREA: 2(12,8' + 25.0') x 2 = 151.2
BOTTOM AREA: 12.8' x 25.0' = 320.0
TOTAL AREA: ......... ................. .......... ....... _ .... ......... 471.2
DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.6 GPD
0WWWO
--2" LAYER OF 1/8" TO 1/2"
DOUBLE WASHED STONE
(OR APPROVED FILTER FABRIC)
TO 1-1/2" DOUBLE
WASHED STONE
DATE: MARCH 17, 2022
SOIL EVALUATOR: PETER McENTEE PE, SE -1542
WITNESS: PHIL RENAUD RS HEALTH AGENT
ELEV. TP DEPTH
99.0
98.3
95.9
94.0
A 0..
LOAMY SAND
10YR 4/2
8"
BLOAMY SAND PERC
10YR 5/8 14"/32"
C1 38
MED. SAND
2.5Y 6/4
C2 60
FINE SAND
2.5Y 7/4
87.5 138"
PERC RATE <2 MIN/IN. "B" HORIZON
NO GROUNDWATER ENCOUNTERED
1
Co
(V
PROPOSED S.A.S.
2-500 GALLON CHAMBERS
SURROUNDED W/4' STONE
S.A.S. LAYOUT
�Nm,"
11=1 t1'1= 1�I'til til til til t='
102
500 GALLON CAPACITY, H-10 LOADING
CHAMBERS
58"
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
68 HIGGINS CROWELL RD, W. YARMOUTH, MA
Prepared for: Joshua Anderson, 68 Higgins Crowell Rd, W. Yarmouth, MA 02673
Engineering by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. N.T.S. P.T.M. 158-22
12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO.
(508) 477-5313 4/5/22 P.T.M. 2 of 2
4" KNOCKOUT
20" DIA. COVER
" KNOCKOUT 04"KNOCKOUT
4" KNOCKOUT
500 GALLON CAPACITY, H-10 LOADING
CHAMBERS
58"
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
68 HIGGINS CROWELL RD, W. YARMOUTH, MA
Prepared for: Joshua Anderson, 68 Higgins Crowell Rd, W. Yarmouth, MA 02673
Engineering by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. N.T.S. P.T.M. 158-22
12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO.
(508) 477-5313 4/5/22 P.T.M. 2 of 2