Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST of.. / 3 , Location: A.M. Lot 4/8 Zone of Contribution: In Out t/ Acreage Ni go,0 / Commercial: Residential: Street: 73 C.4 e u e J ii -f (-J V / Village: / Floor Plan: ✓ #Bedrooms: 3 Owner: VIA,...) a_ -c v A v A r.1 Installer: R v b e r fi Z.3 o u r Address: C Phone: o f b CA �' _ 77' 8877 --- Phone: Builder: Engineer:7-C. k-Tv5 N e e r w.r-' i-iv c Address: Phone: EO g - a 73 - 0 3 7 7 Phone: N/A YES NO 1. Required#of copies received `V� 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table V 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: V 5.Water line 10 ft from septic components Var.:S[ee(IQ p p �j 6.Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation,deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ✓ 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: S' EAS ✓ 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: Nt o-r-n-4.-S ✓ 14.Leaching s- 0 ft above adj.water or bottom of test hole Var.: 1' p* ✓ 15. System not in top or subsoil(A,B horizons)or 5' removal \/ 16.Proposed contours are suitable V 17. System meets slope requirements-nun. 1/8", 1/"preferred ✓ 18. System meets breakout requirements PVC liner: Wall: l/ 19. Specified tee sizes are proper, gas baffle on outlet tee ✓ 20. Sewage is under 10,000 gpd for parcel ,/ 21.No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox ✓ _ 24. Manhole covers within 6"of grade,pump chamber cover to grade ✓/ 25. Inspection port on plastic chambers/leach field ✓ 26.Electrical permit for pump chamber/Separate meter for duplexes V 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed ✓ 29.Vent provided if leaching below 3 feet,under driveway/parking I 30.Buoyancy calculations for tank/pump chamber / / 31.Engineer to inspect and certify soils: wall: commercial: t/ 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater ''✓ / 34.Title V Application and permit fee,installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map 6 03 03 Plan reviewed by: ..