HomeMy WebLinkAbout22-A054 58 Lookout RdYqk TOWN OF YARMOUTH
FIECEIVE
s 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451
Telephone (508) 398-2231 Ext. 1292—Fax (508) 398-0836
APR bt'6-KIN'G'S HIGHWAY HISTORIC DISTRICT COMMITTEE
YAFsiviUU i "
) KING'S HIGHWAY J APPLICATION FOR
CERTIFICATE OF APPROPRIATENESS
Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as
amended, for proposed work as described below & on plans, drawings, photographs, & other supplemental info accompanying this
application. PLEASE SUBMIT 4 copies OF SPEC SHEET(S), ELEVATIONS, PHOTOS, & SUPPLEMENTAL INFORMATION.
Check All Categories That AP I Indicate type of Building:Commercial Residential
1) Exterior Buildin Construction: New Building Addition iterations Reroof IIGarage
Shed LJ Solar Panels Other:
2) Exterior Painting: F Siding II Doors ❑Trim IIOther:
3) Signs/Billboards: .II Ne"l%IFenceWall
nge to Existing Sign
4) Miscellaneous Structures: nFlagpole IIPool IIOther:
Please type or print legibly:
Address of proposed work: 58 Lookout Rd, Yarmouth Port, MA 02675 Map/Lot # 141153
Owner(s): George Bell Phone M 508-736-7572
All applications must be submitted by owner or accompanied by letter from owner approving submittal of application.
Mailing address: 58 Lookout Rd, Yarmouth Port, MA 02675 Year built: 1968
Email: georgeb9049@aol.com Preferred notification method: 11 Phone W1 Email
Agent/contractor: Solar Wolf Energy
Mailing Address: 771 Washington Street, Auburn, MA 01501
Phone #: 508-839-2222
Email: operations@solarwolfenergy.com Preferred notification method: ❑ Phone Z Email
Description of Proposed Work:
Installation of 11.73kW roof mounted solar array using (35) Sunpower 335W all black modules with
built in microinverters; install SMART meter socket
Signed (Owner or agent):
Date: 4/15/2022
➢ Owner/contractor/agent is aware thaYa permit is required from the Building Department. (Check other departments, also.)
➢ If application is approved, approval is subject to a 10 -day appeal period required by the Act.
➢ This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later.
• All new construction will be subject to inspection by OKH. OKH-approved plans MUST be available on-site for framing & final inspections.
For Committee use only:
Rcvd Date: L� 2>
Amount 'In• to
Cash/CK #:t
Rcvd by: L' S
45 Days:
Date Signed:
Approved Approved with Modifications Denied
Reason for Denial:
Signed:
APPLICATION M v' *M
TOWN OF YARMOUTH
1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 02664-4451
I
Telephone (508) 398-2231 Ext. 1292 Fax (508) 398.0836
OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE
WAIVER OF 45 -DAY DETERMINATION
The applicant/applicant's agent understands and agrees that due to the current declared
National and State public health emergencies the determination of our Application for a
Certificate of Appropriate nesslDemoIition/Exemption may not be made within 45 days of the
filing of such application.
The applicant agrees to extend the time frame within which a determination is to be made as
required by the Old King's Highway Regional Historic District Act.
SECTION 9 -Meetings, Hearings, Time for Making Determinations
"As soon as convenient after such public hearing; but in any event within forty-five (45) days
after the filing of application, or within such further time as the applicant shall allow in
writing, the Committee shall make a determination on the application. "
Applicant understands that the review of this application will be scheduled as soon as the
situation allows.
Applicant/Agent Name (please print): Taylor Bennett
Applicant/Agent signature: Date:41152022
77EDE11 ED
APR 2 d 222
YARMUIJ„����nrnY
Application
WORD]
TOWN OF YARMOUTH
OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE
ABUTTERS' LIST
Applicant's (Owner) Name: George Bell
Property Address/Location: 58 Lookout Rd, Yarmouth Port, MA 02675
Hearing Date:
Notices must be sent to the Applicant and abutters (including owners of land on any
public or private street or way) who's property directly abuts or is across the street from
the Applicant. Please provide the Assessor's Tax Map and Lot numbers only. The
OKH Office will send out notices using the addresses as they appear on the most recent
applicable tax list.
Note: Instructions for obtaining the abutters Map and Lot numbers can be found on the Old King's
Highway Department page on the Town website: www.yarmouth.ma.us
Map Number Lot Number
Applicant Information
Abutter Information:
RECEIVED
APR 2 0 2022
VAhW10U
141 53
141
54
141
52
141
46
141
q3
Application #: �p'?W.59
8.2018 3
�RE
APR 2 0 2022
OLD KING'S HIGHVVA'��'
N
__ - It - � -- �-�
LQ
T -
14T (N
T
—
co AT
RT wLr)
T- T"
Lf)
T—
CMT Lf) 00
CN
a
E
Ici
tj
r
1;j
rs
in
CN
Design -Driven Advantages
#1 module aesthetics and efficiency'
unmatched module reliability'
No electrolytic capacitors
25 -year Combined Power and Product
Warranty
California Rule 21 Phase 1 compliant
Maximize Value for Roof
Size system for roof, not string inverter
Optimize performance of each module
Expand Deployment Options
Complex roofs and partial shading
Small systems
System expandability
Simplify & Speed installation
Factory -integrated microinverter
Robust, double -locking AC connectors
Design flexibility offsite and onsite
No DC string sizing process
Fewer installation steps than competing
systems
Intuitive commissioning
Component of Complete System
Built for use with SunPower'9 InvisiMountTM`
and the SunPower Monitoring System (PVS5x)
Superior system reliability and aesthetics
Optimize System and Installation Efficiency
SunPower"AC modules, which include a factory -integrated SunPower
microinverter, provide a revoiutionary combination of high efficiency, high
reliability, and module -level DC -to -AC power conversion. Designed
specifically for use with SunPower InvisiMountTM and the SunPower
Monitoring System, SunPower AC modules enable rapid installation, best -
in -class system aesthetics, and intuitive visibility into system performance.
All this comes with the best Combined Power and Product Warranty in
the industry.
Grid Support Utility -Interactive Smart Inverter
SunPower's new Type D AC module is UL tested and certified to UL 1741
SA and provides advanced smart inverter functions. SunPower Type D AC
modufes are fully compliant with the California Rule 21 Phase 1
requirements, and the Rule 21 grid proMe is easily set during
commissioning with SunPower PVS5x monitoring hardware.
sunpower.com Y
Tested Operating Conditions
Operating Temp. --40`' F tc +185' F t-40` C to +85' C)
Max. Ambient Temp. 122`' F (50' C)
Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back
Snow: 125 psf, 6000 Pa, 611 kg/m2 front
Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s)
DC Power Data
Soiar Cells
SPR-X21-335-BLK-D-AC SPR -X20 -327 -D -AC
Nominal Power" (Pnom)
335 W 327 W
AC Fiecill Data
IEEE 1547a-20143
CA Rule 213
SRD Profile
21.0% 20.4%
(default settings)
min. / nom. / max.
Weight
• Three bypass diodes
min. I nom. / max.
Integrated module -level maximum power point
_
Frequency (Hz)
tracking
59.5 60.0 / 60.5
58.5 ! 60.0 / 60.5
Power Factor
0.99 / 1 00 / 1.00
0.85 lead. / 1.0010.85 lag.
Reactive Power
±169 Var
Voltage
@240 V
211.2 ! 2401264 V
ff
@208 V
183 / 208 / 228.8 V
Max. Current
@240 V
1.33 A
@208 V
1.54 A
DC/AC CEC Conversion Efficiency
@240 V
96.095
@208 V
95.50A
Max. Units Per 20 A Branch Circuit
@240 V
@208 V
12 (single phase)
10 (two pole) wye
I OLD KING'S HIGHWAY
Power
320 W, 320 VA
No active phase balancing for 3 phase installations
Tested Operating Conditions
Operating Temp. --40`' F tc +185' F t-40` C to +85' C)
Max. Ambient Temp. 122`' F (50' C)
Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back
Snow: 125 psf, 6000 Pa, 611 kg/m2 front
Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s)
DC Power Data
Soiar Cells
SPR-X21-335-BLK-D-AC SPR -X20 -327 -D -AC
Nominal Power" (Pnom)
335 W 327 W
Power Tolerance
+5/-0% +5/-0%
.........................................................................._........._................_......._..._......
Avg. Panel Efficiency'
21.0% 20.4%
Temp. Coef. (Power)
-0.2996/°C
Weight
• Three bypass diodes
Shade Tolerance
Integrated module -level maximum power point
Module Spacing
tracking
Tested Operating Conditions
Operating Temp. --40`' F tc +185' F t-40` C to +85' C)
Max. Ambient Temp. 122`' F (50' C)
Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back
Snow: 125 psf, 6000 Pa, 611 kg/m2 front
Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s)
'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014
'#1 rank in "PIV Module Durability Initiative Public Report,' Fraunhofer CSE, Feb 2013. Five out of
the tap eight largest manufacturers were tested- Campeau, 7- et al--SunPnwer Module
Degradation Rate,' SurtPower white paper, Feb 2013- See www-sunpower.comlfacts for details.
'Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during
commissioning. see the Equinox lnstollotron Guide #51810f for more information.
'Standard Test Conditions (1000 wlm2 irradiance, AM 1.5, 25' Q. NREL calibration standard:
SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module.
'Based on average of measured power values during production.
See www.sunpower.com/facts for more reference information.
For more details, see extended datasheet: www.sunpowei.comldatasheeLs.
Warranties 25 -year limited power warranty
25 -year limited product warranty
UL listed to UL 1741 SA
SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA
Rule 21 Phase 1
PV Rapid Shutdown Equipment
Equipment Grounding
UL 6703, UL 9703 Connectors and cables
(load break disconnection)
UL 1741 AC Module (Type 2 fire rating)
Certifications Enables installation in accordance with -
NEC 690-6
NEC 690.12 Rapid Shutdown (inside and
outside the array)
NEC 690.15 AC Connectors, 690.33(A) - (E)(1)
FCC and ICES -003 Class B
When used with InvisiMount racking (UL 2703):
Integrated grounding and banding
Class A fire rated
PID Tes Potential -induced degradation free
A
11071
[43b
1558 mm
IIS- (613 in] -
1046 mm
141.2 In]
9
Please read the safety and installation instructions for details.
pre 11
3C mm
[121.]
hc.nouE
mogrlaerurrnr
a r�rnh
w r,wsuioovm
LISTED
Fho" Fire Wormonae: Type 2
518983 Re. -
Mecharical Data
Soiar Cells
96 Monocrystalline Maxeon Gen III
Front Glass
High -transmission tempered glass with anti -
reflective coating
Environmental Rating
Outdoor rated
Frame
Class 1 black anodized (highest AA_M_A_ra_ting)
Weight
45.5 lbs (20.6 kg)
Recommended Max.
1.3 in. (33 mm)
Module Spacing
'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014
'#1 rank in "PIV Module Durability Initiative Public Report,' Fraunhofer CSE, Feb 2013. Five out of
the tap eight largest manufacturers were tested- Campeau, 7- et al--SunPnwer Module
Degradation Rate,' SurtPower white paper, Feb 2013- See www-sunpower.comlfacts for details.
'Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during
commissioning. see the Equinox lnstollotron Guide #51810f for more information.
'Standard Test Conditions (1000 wlm2 irradiance, AM 1.5, 25' Q. NREL calibration standard:
SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module.
'Based on average of measured power values during production.
See www.sunpower.com/facts for more reference information.
For more details, see extended datasheet: www.sunpowei.comldatasheeLs.
Warranties 25 -year limited power warranty
25 -year limited product warranty
UL listed to UL 1741 SA
SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA
Rule 21 Phase 1
PV Rapid Shutdown Equipment
Equipment Grounding
UL 6703, UL 9703 Connectors and cables
(load break disconnection)
UL 1741 AC Module (Type 2 fire rating)
Certifications Enables installation in accordance with -
NEC 690-6
NEC 690.12 Rapid Shutdown (inside and
outside the array)
NEC 690.15 AC Connectors, 690.33(A) - (E)(1)
FCC and ICES -003 Class B
When used with InvisiMount racking (UL 2703):
Integrated grounding and banding
Class A fire rated
PID Tes Potential -induced degradation free
A
11071
[43b
1558 mm
IIS- (613 in] -
1046 mm
141.2 In]
9
Please read the safety and installation instructions for details.
pre 11
3C mm
[121.]
hc.nouE
mogrlaerurrnr
a r�rnh
w r,wsuioovm
LISTED
Fho" Fire Wormonae: Type 2
518983 Re. -
f
Aurora Shade Report
Customer
George Bell
Address
58 Lookout Road
Yarmouth, MA, 02675
Annual irradiance
Designer
Roily Camartin
Coordinates
(41716681, -70.225509)
Organization
SLinPower (Integratio
Date
8 April 2022
RECEIVED
APR 2 0 2022
YAi;ifviou I1 -i
OLD KING'S HIGHWAY
kWh/m2/year
2,450 or more
2,100
1,750
1,400
1,050
700
350
0
Summary
Array Panel Count Azimuth (deg,) Pitch (deg.) Annual TOF (K) Annual Solar Access (a) Annual TSRF (ia)
1 27 112 30 88 83 73
2 8 202 30 99 79 79
Weighted average
- - - - 82.5 74.6
by panel count
Monthly solar access (%) across arrays
Array Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov pec
1 52 66 85 93 92 93 93 93 89 72 58 44
2 48 68 81 88 88 91 89 88 86 72 57 42
1/3
j
powered by "0(43
Customer Designer
George Bell Rolly Camartm
Address Coordinates
58 Lookout Road (41.716681,-70.225509)
Yarmouth, MA, 02675
Zoomed out satellite view
3D model
Organization
SunPower (Integrate
Date RECEIVED
8 April 2022 APR 2 0 2022
1 iihiviuo i r-
31) model with LIDAR overlay 57 ft
213 powered by aun"
Customer
George Bell
Address
58 Lookout Road
Yarmouth, MA, 02675
Designer Organization
Roily Camartin SunPower i;lntegratiFRECFIVED
Coordinates Date(41.716681, -70.225509) 8 April 2022 PR 2 0 2022
'i ivIUl11t
Street view and corresponding 3D model
4>
I, Roily Camartin, certify that I have generated this shading report to the best of my abilities, and I believe
its contents to be accurate.
3/3 powered by "(Xa
RECiFivEn
APR 2 0 :
13-
' .�
fk
'i
A
5
Vt
; • :'
'7::
'.
y� E..
`f
-
T#
.41
• , # •. '` A
r♦ � !
i