Loading...
HomeMy WebLinkAboutEngineer PlanPARCEL ID: 132/30 i c / TBM ELEV: COR CONC. / STEP=16.00' /' SAVE J / 1500 / TAP ' 7e i 'ARCEL ID: 132/31 / a PARCEL ID: CB 132/27 AREA=20,002± S.F. _ �\ PARCEL ID: 132/26 m Al CB / .jTOF NG' .64 PARCEL ID: 132/29 I34.5' 1f 1 gP 2�o rs9� PX'- O�G CB PARCEL ID: 132/28 7s _ o: �.., / \G ev W � P �CD PER TITLE FIVE n1s 14.4 p ( 40.6' Yumouth Deparbuu j� GRAPHIC SCALE zo 0 10 zo 40 / IN FEET ) 1 inch = 20 ft. YARMOUTHPORT LOCUS 61 HOMESTEAD LANE LOCUS MAP LOCUS INFORMATION PLAN REF: 216/155 TITLE REF: 18029/270 PARCEL ID: MAP 132 PAR. 27 FLOOD ZONE: "X" COMMUNITY PANEL: 25001CO578J DATED:07/16/14 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 61 HOMESTEAD LANE YARMOUTHPORT, MA. PREPARED FOR MARK R. & SUSAN M. GRENIER APRIL 18, 2022 EDWARD \;�n\% 1 +i/o+/' DAVID E.A.S. SURVEY, INC. P.O. BOX 1729 SANDWICH, MA. 02563 CELL: (508)527-3600 EMAIL: eas.survey®yahoo.com SHEET 1 OF 2 415A TOP OF FOUNDATION (10' MIN.) D C.O. EL= 16.0 RISER RISER r 9" MIN. .11� COVER ,, Kiorr 4" a EXISTING 1,500 GALLON TANK (TO REMAIN) GENERAL NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS PORT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 6" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS THEN THEY MUST WITHSTAND H-20 LOADING. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. S. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 2% GRADE OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEES SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6' ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEANOUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES. i'I10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS TI BAFFLE, 4 INCHES IN DIAMETER AND CONTRUCTED OF 4" PVC. '11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND FIRST TWO FEET OUT OF THE DISTRIBUTION BOX SHALL BE LEVEL. 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW 3. NOT IN STATE ZONE B CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARK'. TAPE OR A COMPARABLE MEANS. 15' S= .01 PROFILE OF 4" SCHEDULE 40 P.V.C. SEWAGE DISPOSAL SYSTEM (NOT TO SCALE) EL= 15.3'(FG) / CONC. To RISER & LEVE I COVER r. 6' BAOF MECHANICALLYINVERT SE COMPA3wa-r- PROP. H-2( B6 DIST O BOX W/"T" FG= 15.3 CLEAN SAND FILL PER 310 CMR 15.255 2 OBSERVATION .. SCREWCAP TO GRADE PORTS .I W/ MAGNETIC TAPE t„ VENT „ kk So 1.5' 5 STRIPOUT ) TIE 16" ENDS EL= 12.43 25' (30) ARC 36 HC (H-20) (34.5" X 60" X 16") SOIL ABSORBTION (BED FORMATION) SYSTEM (S.A.S.) 14,2' X 25.0' MIN. 6" OF COVER W/ CLEAN SAND FILL g - � PER 310 CMR 15.255 EL= 13.76 00 I CERTIFY THAT I AM CURRENTLY APPROVED BY THE DEPARTMENT OF ENVIRONMENTAL PROTECTION PURSUANT TO 310 CMR 15.017 TO CONDUCT SOIL EVALUATIONS AND THAT THE ABOVE ANALYSIS HAS BEEN PERFORMED BY ME CONSISTENT WITH THE REQUIRED TRAINING, EXPERTISE, AND EXPERIENCE DESCRIBED IN 310 CMR 15.017. 1 FURTHER CERTIFY THAT THE RESULTS OF MY SOIL EVALUATION, AS INDICATED ON THE ATTACHED SOIL EVALUATION FORM, ARE ACCURATE AND -IN ACCORDANCE WITH 310 CMR 15.100 THROUGH 15.107. DAVID D. FLAHERTY, NEW TEST PIT RESULTS: SOIL EVALUATOR SOIL TEST DATE: MARCH 31, 2022 B.O.H. AGENT: BRUCE G. MURPHY, R.S. SOIL EVALUATOR: DAVID D. FLAHERTY,JR., SE BACKHOE: ELLIS BROS. TPA3 Fl.= 14.4 SFIVF TEST(<2 MPI) DOWN CAPE ENG. ELEV. DEPTH (IN.) HORIZON TEXTURE COLOR MOTTLING OTHERI 12.9 0"-18" FILL 1.3 7.1 1 36"-98" 11.7 18"-31" A LOAMY SAND 10YR3/2 N/A 10.9 31"-39" B LOAMY SAND 1OYR5/6 N/A 5.2 39"-110" Cl SILT CLAY LOAM 10YR6/6 N/A 1.2 110"-158" C2 MED./COARSE. SAND 2.5Y6/5 N/A GROUNDWATER EL.= 15 cape eng. OLD ELEV. I DEPTH (IN.) HORIZON TEXTURE COLOR MOTTLING OTHER 12.3 1 0-36" X FILL C 1 SILT LOAM 110YR5ZA 1.3 7.1 1 36"-98" C 1 SILT LOAM 10YR6 6 2.3 98"-156" C2 I FINE & COAR. SAND 2.5Y6/4 LAYERED TH#2 EL.= 15.1GKOUNUWAItK AI 11U LLtV.=b.1 34.5" Y J10.5" y 34.5" Y PROFILE END (FIVE ROWS OF FI OBS WELL SDW252R ADJ. MAR 2022 A - TEST PIT RESULTS: s DATE: 03/15/12 AGENT: AMY VON HONE EVAL: EDWARD A. STONE BACKHOE: WARREN MIRANDA ELEV. I DEPTH (IN.)IHORIZONI TEXTURE COLOR MOTTLING OTHER 11.1 0-48" FILL 5.9 48"-110" C 1 SILT LOAM 110YR5ZA 1.3 110"-166" C2 FINE & COAR. SAND 2.5Y6/4 34.5" Y {EL= 12.43 =0.7 7.4/J. NDWATER AT 6.7 AD '. =0.7 DESIGN DATA: NUMBER OF BEDROOMS.........{ 4 ,I 9 GARBAGE DISPOSAL................`.0 _ TOTAL TIMATED FL (110 GAL./BR./DAY X 4 BR.) 4446',) _ 440GPD X 200% = 880 GAL USE EXIST. 1500 GAL, TANK INSTALL: 25 ARC 36 HC (H-20) AND BACKFILL WITH CLEAN SAND FILL PER 310 CMR 15.255 6" MIN. ABOVE AND BETWEEN UNITS SOIL CLASSIFICATION ................ DESIGN PERCOLATION RATE..... < MIN_/LN. EFFLUENT LOADING RATE ......... __74___ REQUIRED LEACHING CAPACITY....440 GAIDAY LEACHING CAPACITY PROVIDED..... 444 GALLDAY 5 UNITS X 5 ROWS X 5.0 LF/UNIT X 4.80SF/LF = 600 600(.74)= 444 GAL/DA 'TOTAL= 444 GAL/DAY 444 GPD PROVIDED - 440 GPD REQUIRED = 4 GPD RESERVE DAVID SEPTIC SYSTEM DETAIL PAGE D. 1. 61 HOMESTEAD LANE H Y .J ? YARMOUTHPORT, MA. APRIL 18, 2022 dAllAa+� SHEET 2 OF 2 J# 1415A