Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST 16, .L . . Location: A.M. 2 S Lot 13 3 Zone of Contribution: In_ Out '/Acreage /f,o Z-Z-: S Commercial: Residential: 1.,-- Street: I S/ cm---- /4-r.>E Village: Floor Plan: .Ud #Bedrooms: 3- `/ 'S&L LA- Owner: PR-4A(PA-S Installer: G2J/ i2- Address: Phone: Phone: 18(- -7 6 0 l 8 Builder: Engineer: B5C Address: Phone: Phone: N/A YES NO 1. Required#of copies received I/ 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table V 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓" 5.Water line 10 ft from septic components Var.: ✓ 6.Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: j - 9.Leaching minimum 100 ft from wetlands Var.: ✓ 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: / 14. Leaching set LE5 above adj.water or bottom of test hole Var.: / 15. System not in top or subsoil(A,B horizons)or 5' removal / I 16.Proposed contours are suitable V 17. System meets slope requirements-min. 1/8", '/"pre :i -a / 18. System meets breakout requirements PVC ner: Wall: i 7 19. Specified tee sizes are proper, gas baffle on outlet tee 7- 20. Sewage is under 10,000 gpd for parcel V 21.No garbage disposal 22. System adequately sized for its intended use I 7 23.Minimum 6"stone or compacted below tank and dbox %/ 24. Manhole covers within 6"of grade,pump chamber cover to grade / 25. Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 7 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size V 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking V 30.Buoyancy calculations for tank/pump chamber / --- 31.Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian d Land Surveyo amps/signature 33.1-1-20 loading is subject to vehicular tr c, goun water 34.Title V Application and permit fee,installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd V 37.Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by. S IA- 4 1 (-24 27_ 6 01 03