HomeMy WebLinkAboutEngineer PlanSYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM MULTI -FAMILY DWELLING (2BR EA.) DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD TOP FOUND. EL 33.2' USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 (FIRST COMPARTMENT) PRECAST H-10 RISERS (TYP.) **REUSE A 1000 GAL. SEPTIC TANK 31.61 SEPTIC TANK: 440 GPD (1) = 440 (SECOND COMPARTMENT) io- EXISTING 14" USE A 1000 GAL. H-10 SEPTIC TANK TEE SEPTIC TANK** TEE GAS BAF LEACHING: SIDES: 2 (33.5 + 12.8) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.8 (.74) = 317 GPD TOTAL: 614 S.F. 454 GPD USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND FOUNDATION EXIST. SEPTIC TANK *THE INSTALLER SHALL VERIFY THE **INSTALLER SHALL CONFIRM MINIMUM LOCATIONS OF ALL UTILITIES AND ALL SEPTIC TANK SIZE AT 1000 GALLONS BUILDING SEWER OUTLETS AND AND ITS SUITABILITY FOR RE -USE. ELEVATIONS PRIOR TO INSTALLING ANY REPLACE WITH 1500 GALLON SEPTIC PORTION OF SEPTIC SYSTEM TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE SYSTEM PROFILE (NOT TO SCALE) ALL SYSTEM COMPONENT'S SHALL BE j MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. ACCESS COVERS TO WITHIN 6" OF. FIN. GRADE 2" PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE FILTER FABRIC OVER STONE 32.3 MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 30.5'-31.5 PRECAST H-10 - WATERTEV D'BOX FOR LEVELNESS BLOCKS OR. RISERS C".) MIN. 2 W ICKNESS PRECAST RISERS 4"OSCH40 PVC. MORTAR ALL INVERT IN 27.8' PIPES LEVEL IST 2' COMPONENTS 4 ENDS (TYP.) SIDES 28.8' * TE0. E 1000 GAL H-10 14 TEE 6" MIN SUMP ®®� 30.28'f SEPTIC TANK 29.95' oaoaoaoa o F= 0 m�Mmm \ °+�`o�n�?�a�a9 12••.MIN. INT. DIM. .moi ,. ®���8 mmmmm 30.20' GAS BAFFLE ®®mmmmmm®mm mmmmm®®mmmm 28.27' 28.1 25.8' 4 UQ. LEVEL ACME OR. EQUAL 0000a 'H-20 500. GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL o3/4"-1-1/12 0 0 0 0o'^•o" 0 0 0 0 0"0"0 0"0 0" DOUB 0 0"0 0 o`a.LE WASHED STONE 4'. MIN. • o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 0 3 UNITS REQUIRED a 00000aoa0ao ooPRECAST ( ) 0 000ao�o�o�0 0 9.000 . � ALL AROUND _ _ STRUCTURES OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.5' X 12.83' } 6' CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) (-Lx %. SLOPE) (2.9 % SLOPE) (. 3 % SLOPE) H-20 20.8' BOTTOM. TH-1 4' SEPTIC TANK 58' D' BOX - 12' LEACHING No GROUNDWATER FOUND FACILITY DCE ##22-008 C 0 NOTES DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING VENT W/ CHARCOAL FILTER 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -21f (H-10) TANK) 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLEMATERIALENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED -WITH CLEAN SAND. 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991--. P.RQ2DSED=L N1aUR [98-4] PROPOSED SPOT EL. TH1 £ O 0 TEST HOLE 2%� SLOPE OF GROUND andy P d UTILITY POLE yrs FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN ORWNG UNIT #4 UNIT #2 (LOCUS) BED BED BED BATH I BATH KITCHEN) KITCHEN LIVING DINING DINING ROOM FLOOR PLAN (N. T ss) N0110E REQUIRED. LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 49 PARCEL 29-C2 AND 29-C4 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF 'MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO586J DATED 7/16/2014 SITE IS LOCATED WITHIN A STATE ZONE TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD DATE: 2/17/22 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 31.3' - A - LS 8.. 1OYR 4/1 -; B LS BED 24„ 1OYR 5/8 29.3' LIVING ROOM Yarmouth Health Department APPROVED ame Date C PERC MS 1OYR 7/6 126" 20.8' NO GROUNDWATER ENCOUNTERED TITLE 5 b" ITE PLA"Nffi OF 205 HIGGINS CROWELL RD WEST- YARMOUTH, MA PREPARED FOR BORTOLOTTI CONSTRUCTION/ BRYAN FAIRBAIR`N A cocheset DATE: MARCH s m � sosseti Pond O z? o� 0 ao Scale:1"= 20' £ O Horse Pond .andR k Igl g�c Locus andy P d IELyam D e � 0 m v5 40 50 FEET LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 49 PARCEL 29-C2 AND 29-C4 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF 'MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO586J DATED 7/16/2014 SITE IS LOCATED WITHIN A STATE ZONE TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: PHIL RENAUD DATE: 2/17/22 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 31.3' - A - LS 8.. 1OYR 4/1 -; B LS BED 24„ 1OYR 5/8 29.3' LIVING ROOM Yarmouth Health Department APPROVED ame Date C PERC MS 1OYR 7/6 126" 20.8' NO GROUNDWATER ENCOUNTERED TITLE 5 b" ITE PLA"Nffi OF 205 HIGGINS CROWELL RD WEST- YARMOUTH, MA PREPARED FOR BORTOLOTTI CONSTRUCTION/ BRYAN FAIRBAIR`N A DATE: MARCH 1, 2022 ate. "qs Scale:1"= 20' RECEIVED IELyam MAR 14 2022 m 0 10 20 30 40 50 FEET LA HEALTH DEPT. 1980 �P °°P off 508-362-4541 tvE I fax 508-362-9880 downcope.com iD j owa cope WAI0 tering, file. civil engineers I' _ `,� _- / .d ...._ land surveyors 6 939 Main Street ( Rte 6A) i DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 i 22-008"BORTOLOTTI-FAIRBAIRN,DWG