ARCHITECT’S SITE OBSERVATION REPORT
DATE OF VISIT: 04/21/2022 PROJECT: Dennis Yarmouth Intermediate
Middle School
286 Station Avenue
South Yarmouth, MA 02664
DATE OF ISSUE: 04/26/2022 PROJECT NO: 71011
WEATHER
CONDITIONS:
Sunny, clear, low 60s ARCHITECT: Perkins Eastman, DPC
20 Ashburton Street
8th floor
Boston, MA
The purpose of the Site Observation Report is to record general observations of the work in progress at the time of the Architect’s visit.
WORK IN PROGRESS:
1) Interior partition framing and drywall
2) Painting
3) MEP rough-in
4) Fire protection
5) Elevator installation
6) Door frame installation
7) Misc metals
8) Concrete deck installation
9) Curtain wall installation
10) GFRC panel girt installation and insulation
11) Brick masonry and CMU
12) Fluid-applied AVB installation at GYM
13) Exterior sheathing at A
14) Site work at the upper sports field
FIELD OBSERVATIONS:
PE visited the site on Thursday 04-21, to review ongoing progress.
1. Sheetrock installation is ongoing at area D and C, and Colony is in the process of taping and sanding ahead of
the painting crew at Area D level 1.
2. O’Byrne’s crew is painting classrooms in Area D (see photo on page 2).
3. MEP installation at Area D is continuing to focus on preparing ceiling plenum areas for ceiling work to begin
during the week of 4-24.
4. MEP rough-in is ongoing in Area B
5. Door frames are being set in Area B
6. At the time of observation Silverback had just poured the composite deck for the two uppermost tiers at the
auditorium (see photo on page 3).
7. Elevator installation is ongoing (both elevators)
8. United Steel is on site doing field measurements for the monumental stair base and the roof ladders.
9. Moving to exterior items, Colony is continuing to sheathe the music room wing; at the time of observation they
were installing blocking for the curtain wall openings in C.
10. Lighthouse has completed the exterior CMU back up wall at custodial work area (see photo on page 4); brick
masonry work is finishing up at the south side of Area D at the time of observation there were two crews laying
brick: one at the south-central facade of C and one at the north-west.
11. For the gymnasium, the CMU work is complete and Lighthouse is installing the PCC base at the west side.
12. Liquid applied AVB installation at the gymnasium has commenced ,and the west wall appears substantially
complete.
REPORT BY: ABH Page 2 of 4
13. The Lambrian crew is installing the central curtain wall at the gym (see photo on page 3) and is continuing to
install the CW at the “bridges” (Area B-C).
14. Lymo is substantially done with clips and mineral wool for the GFRC panels at Area D and Area C, and are
working on the girts and insulation for the ACM at the bridges. (See photo on page 4)
15. Site progress: RBO is doing rough grading and laying drain pipe for the athletic fields; preparing to install bases
for the storage sheds. See attached Traverse site report for more details on site progress.
DISCREPANCIES, SPECIAL INSTRUCTIONS
4211. Miradrain issue at turf fields. CB, RBO, PE, Traverse, and PMA met to review RBO’s progress and to
discuss Traverse’s RFI 340 response (saying not to use drainage fabric above the drain pipe at the synthetic
turf). Also see attached Traverse site report.
4212. Facia plate at auditorium. Per measurements by United, the steel fascia at the balcony was installed ½” too
low, so that the edge of the porcelain tile will show. PE to look at options and direct.
4213. Steel protrusion at auditorium. Paul Genereux (CB field super) asked about the steel frame that is protruding
slightly at both sides of the upper auditorium. This will need to be concealed with a bump-out (+/- three
inches). CB to review with theater seating contractor for possible impact on seat layout.
4214. Slab depression at kitchen. Paul Genereux asked about the ½” slab depression at the kitchen, which CB
believes is incompatible with the specified (non-poured) epoxy floor. PE to research.
Prior Items
4141. (from 04 14 site report) Poorly plumbed column at A.17/V. CB pointed out that the upper part of the HSS
column at A.17/V (auditorium lobby) impinges on the interior space by more than an inch. PE and the Colony
foreman discussed a solution that would involve furring out with 7/8” furring channels (see photo). still open.
4142. (from 04 14 site report) Accent paint at classroom walls. PE had O’Byrne to make the main wall color carry
across the accent wall above the horizontal reveal and to use P-09 (yellow) around the doorway on the
classroom side. Update: PE approved classroom paint mockup installation with minor comments (see photo
below) – this item is being closed.
3311. (from 03 31 site report) Missing expansion joint. Update: Colony has addressed the missing expansion
joint on level 2 as requested on 3-31 (see 4-07 report), but still needs to tweak the location of the first floor
EJ: Colony confirmed that 2nd floor WRM was coordinated, and PE approved location of EJ on level 2.
3173. (from 03 17 site report) Curtain wall at gym corner. still open.
31002. (from 03 10 site report) Exposed HSS support brackets in gym.. still open
22402. (from 03 03 site report) Caulk color Update: “Beige” caulk was approved (see photo on p. 3). t/b closed.
11301. (From 01-13 site report): Guard rail welds at D & C stairs - United still needs to grind welds for guards at
academic stairs (see photo). Update: PE reviewed this item with United and CB emphasized schedule
issue-still open.
Attachment:
· Landscape Architect’s site report from 4-21
SITE PHOTOS
CLASSROOM PAINT COLOR MOCK-UP (AREA D)
REPORT BY: ABH Page 3 of 4
APPROVED BRICK CJ CAULK TYPICAL SUNSHADE MOCKUP CW INSTALLATION AT GYM
RECENTLY-INSTALLED DECK AT AUDITORIUM UPPER TIER
REPORT BY: ABH Page 4 of 4
(AREA C NORTH WEST)
GREENGIRTS FOR ACM AT EAST ‘BRIDGE’ (AREA C TO AREA D)
MASONRY BACKUP WALL AT AREA A – WEST WAL
Traverse Landscape Architects
150 Chestnut Street 4th Floor
Providence RI, 02903
Landscape Architects Field Observation Report
DYIMS
296 Station Avenue
South Yarmouth, MA 02664 (US)
Report number: K1008-7
Date: April 21, 2022 08:51 AM
Attendees and Distribution
Role and company name Name Contact information Present Sent
Project Manager
[Commodore Builders]
RIcky Suqhrue 508-463-7958
rsughrue@commodorebuilders.com
✔
Landscape Architect
[Traverse Landscape Architects]
Arthur Eddy (401) 383-4950
aeddy@traversela.com ✔
OPM Rep
[PMA Consultants]
Chad Crittenden 781-519-1076 ✔
Assistant Project Manager
[Commodore ]
Timeo Sequeira 774.628.8065
tsequeira@commodorebuilders.com ✔
Site Contractor
[Robert B. Our]
Kevin Trombly KTrombly@robertbour.com
✔
Senior Associate
[Perkins Eastman]
Andrew Hazelton 1-617-449-4057
a.hazelton@perkinseastman.com ✔✔
Discussions on Site
Report created by Art Eddy 1 / 7
150 Chestnut Street, 4th Floor • Providence, RI 02903 • 401.383.4950 • www.traversela.com
Observations
Observation Description
Athletics
✔ Fields 7.1 The perimeter pipe was installed in approximately 85% of the field with 3/4" cleaned stone in 1/3 of the trench.
April 21, 2022 02:19 PM
Report created by Art Eddy 2 / 7
150 Chestnut Street, 4th Floor • Providence, RI 02903 • 401.383.4950 • www.traversela.com
Report created by Art Eddy 3 / 7
150 Chestnut Street, 4th Floor • Providence, RI 02903 • 401.383.4950 • www.traversela.com
Report created by Art Eddy 4 / 7
150 Chestnut Street, 4th Floor • Providence, RI 02903 • 401.383.4950 • www.traversela.com
✔ Reviewed the 3/4" stone
that is used in the trench and
discussed per RFI# 340. The
stone is acceptable to be used
in the trench. 7.2
Report created by Art Eddy 5 / 7
150 Chestnut Street, 4th Floor • Providence, RI 02903 • 401.383.4950 • www.traversela.com
✔ The base stone for the
field was reviewed. The stone
sample is acceptable for use.
Reviewing the stone, it is
acceptable to bring the base
stone to the surface and
eliminate the finish stone.
7.3
✔ It was discussed in the field that the subgrade needs to be rolled and surveyed prior to acceptance. The subgrade needs to be visually inspected prior to
fabric, stone and flat drain being placed. 7.4
✔ DMH8 was reviewed in
the field. RBO has moved the
manhole 6' into the field from
the curb. The manhole should
be set 6" below the finish
stone. The top of manhole
cover should be set flush with
the top of the finish stone.
The cover will be under the
7.5
It was discussed to cover the trench with filter fabric. This is not allowed within the field. Traverse explained the issue with filter fabric clogging the
system and creating an air pocket that could potentially float the field. 7.6
✔ It was discussed that there would be a pre-construction meeting set up to review the field sequencing, requirements and schedule. 7.7
Station Ave field, RBO indicated that there is an electrical line that runs from the existing drive to the side of the admin building. RBO indicated that they
were having the line located to coordinate. 7.8
✔ The cover of the football upright was discussed. Traverse indicated that a cover with a metal top and rubber gasket to protect the athletes was required.
7.9
Report created by Art Eddy 6 / 7
150 Chestnut Street, 4th Floor • Providence, RI 02903 • 401.383.4950 • www.traversela.com
✔ The pad for bleacher was
formed and WWM was
present. 7.10
Contractor shall refer to the photos and observations above.
Contractor shall comply with all requirements instructed by the Landscape Architect on all previous field reports until such requirements are fulfilled. The
Landscape Architect shall not be responsible for any items not addressed in previous field reports which may result in cost or damage. All work shall comply with
that which is shown in the Contract Documents.
General conditions
Site visits performed by the Landscape Architect under this contract have been conducted under the limited conditions as described by site observations in the
General Conditions of the Contract for Construction, as referenced in the Owner-Architect Agreement.
Information contained in this Field Observation Report by Traverse Landscape Architects has been prepared to the best of our knowledge according to
observable conditions at the site. This information will be approved record unless written notice to the contrary is received within seven (7) calendar days of
the issue date of this document. Written corrections shall be reported to observer at Traverse Landscape Architects. Oral rebuttals will not be accepted.
Report created by Art Eddy 7 / 7
150 Chestnut Street, 4th Floor • Providence, RI 02903 • 401.383.4950 • www.traversela.com