Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2022 Sign off Tranmittal - Remodel existing house
.-E=Y' .s TOWN OF YARMOUTH 41. HEALTH DEPARTMENT PERMIT APPLICATION SIGN OFF TRANSMITTAL SHEET To be completed by Applicant: Coy Building Site Location: S Co E C€ ? IA Ct f t I C Proposed Improvement: -ern Se( -64 f i I hoJcc Applicant: 6ell/C0/ )--1 6-re k) Tel.No 7744 am. cf )/ • Address: vv G er Icing Cc`,i c (-( Date Filed: I I— 7- **If you would like e-mail notification of sign off,please provide e-mail address: 6e/7 e jreu 6'ui 1 d •1 J eon , Owner Name: gI f f) 6`le Owner Address: 6-6, 6/".e en toil ((1Y( /-c. Owner Tel.No.: RESIDENTIAL AND/OR COMMERCIAL BUILDING HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e.,Requirements For Septage Disposal and other Public Health Activities. Please submit three (3) copies of plans,to include: (1.) Site Plan showing existing buildings,water line location, and septic system location; _... _. __ (2.) Floor plan labeling ALL rooms within building (all existing and proposed)— 0 -62 Note:Floor plans not required for decks,sheds,windows,roofing; rr r• PT (3.) If necessary,Title 5 application signed by licensed installer with fee. REVIEWED BY: DATE: `G /0`� /' -\ (% PLEASE NOTE COMMENTS/CONDITIONS: 6A i SETUCKET ROAD N I ti GREENLAND CIRCLE 2 31� LDCUS LOCUS MAP NOT TO SCALE OT 108 LOT 109 NOTES TRIC COMPANVEASEMENT 180'W/DE LOT 911 20,936± S.F. 0 LOCUS INFORMATION PROPOSED NEW CURRENT OWNER: BENJAMIN GREW & OVERLAY DISTRICT: APD / OKH _ /AREA__ VANESSA RAMALHO UPL 59.0' TITLE REFERENCE: CTF. 210349 NITROGEN SENSITIVE ZONE: ZONE II PLAN REFERENCE: LC PLAN 36848-C, SH 3 FEMA ROOD OVERHEAD ELECTRIC LINE o EHH ELECTRIC HANDHOLE ZONE DISTRICT: "X", DATED 7-16-14 ASSESSORS MAP: 135 N PANEL #25001CO579J PARCEL: 153 —W— WATER LINE ❑M MAIL BOX MINIMUM LOT SIZE: 40,000 S.F. ZONING DISTRICT: R-40 EXISTING LOT SIZE: 20,9381 S.F. SETBACKS: FRONT 30' © 2021 The BSC Group, Inc. SCALE: 1' — 20' 0 2.5 5 10 SIDE 20' EXISTING BUILDING COVERAGE: 2,1273 S.F. (10.2%) CALC./DESIGN: K. HEALY REAR 20' PROPOSED BUILDING COVERAGE: 2,4591 S.F. (11.8%) TRIC COMPANVEASEMENT 180'W/DE LOT 911 20,936± S.F. 0 CATCH BASIN DMH 0 PROPOSED NEW 0 2E.ElT g'y40' PORCH EA TELEPHONE MANHOLE _ /AREA__ LIGHT POLE UPL 59.0' UPLT UTILITY POLE / LIGHT & TRANS. UPT �. UTILITY POLE / TRANSFORMER UP UTILITY POLE S LAWN MOWER \>. LEAN-TO � t^ #56 EXISTING STORY DWELLING � 64.0' BIT. 1 PARKING/� 1 / / GRAVEL j PARKING/ 5.6' �s`•\ ``J SEPTIC SYSTEM n LOT 112 EASEMENT AREA REFERRED TO IN DOCUMENT 89250 AND DEPICTED ON 'PLAN OF EASEMENTS, DATED 1982 AND INCLUDED IN DOCUMENT 89250 AND UTILITY EASEMENTS DEPICTED ON LAND COURT PIAN 6848-C-3. A 2 BEDROOM DEED RESTRICTION HAS BEEN PLACED ON THE PROPERTY AND RECORDED AS DOCUMENT 1,300,537 IN 2016. THE EXISTING SEPTIC SYSTEM IS APPROXIMATE AND IS BASED ON A TIE CARD ON FILE AT THE YARMOUTH BOARD OF HEALTH. ELECTRIC SERVICE LOCATION TO THE BUILDING HAS NOT BEEN CONFIRMED AT THIS TIME. L LOT 190 �O e0. 0 HELD /PAVER~I PATIO 1 FIRE PRY 1 U O 4 m LEGEND C.B. 0 CATCH BASIN DMH 0 DRAINAGE MANHOLE SMH T SEWER MANHOLE TMH 0 TELEPHONE MANHOLE LP LIGHT POLE UPL UTILITY POLE / LIGHT UPLT UTILITY POLE / LIGHT & TRANS. UPT �. UTILITY POLE / TRANSFORMER UP UTILITY POLE —0 W— OVERHEAD ELECTRIC LINE o EHH ELECTRIC HANDHOLE O GMET GAS METER — G— GAS LINE N GAS GATE WG ® WATER GATE —W— WATER LINE ❑M MAIL BOX REVISIONS: NO. DATE DESC. I CERTIFY TO THE BEST OF MY PROFESSIONAL KNOWLEDGE, INFORMATION AND BELIEF THAT THE LOT CORNERS, DIMENSIONS AND SETBACKS TO THE STRUCTURE AS DETERMINED. BY INSTRUMENT SURVEY AND AS SHOWN ON THIS PLAN ARE CORRECT. tyyixBF o� KIERANN j. . �.. MEAI:Y a o. NO.4B936 FS pF4r9TEPa'� S2 Rt LAND x KIERAN FJ HEAL);f`PLS .-"bATE FOR THE BSC¢'GROUP, INC. CERTIFIED PLOT PLAN WITH PROPOSED FRONT PORCH AT -_..-- #56 GREENLAND CIRCLE IN YARMOUTH MASSACHUSETTS (BARNSTABLE COUNTY) NOVEMBER 4, 2021 PREPARED FOR: BENJAMIN GREW 56 GREENLAND CIRCLE YARMOUTH PORT, MA 02675 774-212-4718 BEN ®G R E W B U I LD I N G. CO M -, BSC GROUP 349 Route 28, Unit D West Yarmouth, Massachusetts 02673 508 778 8919 © 2021 The BSC Group, Inc. SCALE: 1' — 20' 0 2.5 5 10 0 10 20 40 ,... PROJ. MGR.: CRAIG FIELD FIELD: S. CROWLEY CALC./DESIGN: K. HEALY DRAWN: K. HEALY CHECK: CRAIG FIELD FILE: 50605-CPP.DWG DWG. NO: 6770-02 SHEET 1 OF 1 JOB. N0: 5-0605.06 M BEDROOM 2 BEDROOM K GHEN 1 19' "X 131-8" H II �J II it GARAGE 12•-9••X26'-3•' ENTRY BEDROOM 1 VIN& 21' " X 13'-9" LI IN(5 AREA 1 I I I 1 I I i JT 144150 FT 1st Floor UP 8" CONCRETE WALL WI FOOTING EX BTING FOUNDATION o 0 0 o GARAGE OE \4°LALLY COLUMNS 8'0.C. 72'AR Exlatlng Gross Section Existing Foundation & 5ill Detail 0C 16"O.C. 610.0, a s ° � f o � > z 0 ovg a Q u mei p¢5m °Ut�vNo DATE: 9/29/21 SCALE: v4^-1• SHEET: 12 piton 2x8 Rakers (2)11/4 LVL 4x4 post (2)2x8 P .beam �IgiO P._ ABA44Zm standoff connector [y.1 10" Sonat a w/bigfoot Porch elevation n¢onala�wrmp¢¢ II¢'cf=nWwor oir,s tsae ews. uLe�i..Poea.¢aRl InB Faxla 11]"LO%FLINbO n¢oNN %b®la"Oc I�m.....� a.,rrasL,I.e�L � m..e.p�m vx•sw.ao.eo R21rm.i- 110, Eave Detail Exterior Wall Detail Gross Section back gable 2nd Floor ii i Determine on site if 4' tally column /footing In basement i is necessay. TBD < � WALK IN CLOSET m KITCHEN .mn o� 10'-11"X13'4" 19'-5"X13'-61 -1€ m -h 2 ' p'V rINo Add post in extsror wall GARA6E for LVL beam DATE: 19/29/21 V-63/4' I - ENTRY 12'-1"X 19'-1" MASTER BEDROOM x --- 15'-6"X 13'-51, LIVING 19'-5" X 13'-W 15'4 1116" I / exisxe rh8l,e� 2x8 P Tjolsts(2)P.T. 2%Bbeam hd \ bigfoat 10' 10' >k- 10' 40 12 piton 2x8 Rakers (2)11/4 LVL 4x4 post (2)2x8 P .beam �IgiO P._ ABA44Zm standoff connector [y.1 10" Sonat a w/bigfoot Porch elevation n¢onala�wrmp¢¢ II¢'cf=nWwor oir,s tsae ews. uLe�i..Poea.¢aRl InB Faxla 11]"LO%FLINbO n¢oNN %b®la"Oc I�m.....� a.,rrasL,I.e�L � m..e.p�m vx•sw.ao.eo R21rm.i- 110, Eave Detail Exterior Wall Detail Gross Section back gable 2nd Floor Second Floor Framing Plan L_ '. SHEET: ii 11 Determine on site if 4' tally column /footing In basement i is necessay. TBD < � m o� (Mil 1/4"x13/4"LVL -1€ m -h 2 p'V rINo Add post in extsror wall for LVL beam DATE: 19/29/21 SCALE' Second Floor Framing Plan L_ '. SHEET: