Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. of 3 Lot 17,. Zone of Contribution: In Out-----Acreage /01 7'6 Commercial: Residential: L„.....- Street: 3 4 e r ia S Lc_ , 1-1‘) Village: Floor Plan: #Bedrooms: 3 Owner: Z e rFe:y Lar ea.0 Installer: 0 u i r k Address: Phone: so 2 - Llo c7 /3,',5- Phone: Ai/3 3 8 5'. - Q qr 3 0 Builder: Engineer: �.;c c it- (- Address: Phone: 6c,g - 3gs - Gqoc, Phone: N/A YES NO 1. Required#of copies received V/ 2.Date of soils exam and percolation test not older than 2 years t� 3.4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: %./.- 5. 5.Water line 10 ft from septic components Var.: 1/4 6.Benchmark indicated and shown-NGVD if near wetlands / , 7. Septic tank minimum 10 ft from foundation, deck Var.: `�// _ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: _ ‘/'` 9.Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V/ 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: • ) 15. System not in top or subsoil(A,B horizons)or 5' removal ✓� 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred L‘..k 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal ✓ 22. System adequately sized for its intended use �/ 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field Y 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater r./ 34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house "‘ --'/ 36.Deed Restriction required max. #bedrooms: max. flow: gpd t // 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: / /� y, ,) Z