Loading...
HomeMy WebLinkAbout2022-04-22 - BRIGGS -Reinforcing Steel Report - Bathroom & Flowrider Foundation Wallsc.r.s.i.rev2,02 Concrete Reinforcing Steel Report Briggs Engineering & Testing PROJECT: A Division of PK Associates, Inc.PROJECT#: INSPECTOR: EMP.#:DATE:CODE: PAGE OF TEMP.:H 54F L WIND: H L √HUMID: H L √ Reinforcing steel was inspected for arrangement, cleanliness and checked against working drawings and reference specifications of ACI-301 for the following items. Check marks indicate compliance. All items in non-compliance are either corrected during inspection or noted below. Size and location:Clearance to forms: Grade Strength:Extra bars at openings: Splice Lapping:Adequate ties: Spacing:Concrete coverage: Supports:Stirrup spacing: Location and Drawing #:Bathrooms: foundation walls Drawing #:S- 101, Dated 03/01/22 Flow rider: foundation walls Drawing #:AQ3.02, Dated 01/25/22 Remarks:A reinforcing steel inspection was performed for the above location. All reinforcing steel inspected conformed with the appropriate drawings/ specifications. Bathrooms: foundation walls- Vertical bars at 12" on center= ok. (2) #5 Horizontal bars continuous, each face top= ok. Corner bars= ok. Flow rider: foundation walls- Vertical bars, horizontal and corner bars (each face/ each way)= ok. Note: water stop installed at required location= ok. Note: All test results and findings contained within this report are limited to the areas indicated. 100 Weymouth St., Unit B-1, Rockland, Ma 02370 100 Pound Rd., Cumberland, RI 02864 Approved: Director of Field Operations:YHSean Skorohod CC INFLATABLE PARK/ W. YARMOUTH 31987 Robert Carter 04/22/22 √ √ Sean Skorohod √ N/A √√ √ √ √ √