HomeMy WebLinkAbout2022-04-19 - BRIGGS - Reinforcing Steel Report - Pump House Footings, Restroom Wallsc.r.s.i.rev2,02 Concrete Reinforcing Steel Report Briggs Engineering & Testing PROJECT: A Division of PK Associates, Inc.PROJECT#: INSPECTOR: DATE:CODE: PAGE 1 OF 1 JOB HRS.: TEMP.:H 56ºL 52ºWIND: H 20mph L 18mphHUMID: H 86%L Reinforcing steel was inspected for arrangement, cleanliness and checked against working drawings and reference specifications of ACI-301 for the following items. Check marks indicate compliance. All items in non-compliance are either corrected during inspection or noted below. Size and location:Clearance to forms: Grade Strength:Extra bars at openings: Splice Lapping:Adequate ties: Spacing:Concrete coverage: Supports:Stirrup spacing: Location and Drawing #:1)Pump House Ftn 2)Restroom Walls Reference: S.101 and S.102 (4), (5), (6), (7) Date: 03-01-22 1)Pump House D (4) #5's at 12" o/c E.W (3" Wire Chair Support at Bend to O.F) Verts - #6's at 8" o/c (Hooks to O.F) and #5's at 12" at 12" o/c L.W (2 #5's Top) D (5) #5's at 24" o/c + (3) #5's Continuous D (6) #5's at 12" o/c E.W (3" Wire Chair Support at O.F Bends) Verts #6's at 8" o/c and 5's at 12" o.c L.W At Sump Pit D (7) #5's at 8" o/c (V) and #5's at 12" o/c L.W #5's at 12" o/c E.W 2)Rest Room Walls D (1) S-102 = #4's at 24" o/c #5 Corner Bars and Set-up Bar Remarks:A reinforcing steel inspection was performed for the above location. *4" Clearance from Grade Note: All test results and findings contained within this report are limited to the areas indicated. 100 Weymouth St., Unit B-1, Rockland, Ma 02370 100 Pound Rd., Cumberland, RI 02864 Approved: Director of Field Operations:MG Sean Skorohod 2.0 + 68 √√ CC INFLATABLE PARK/W. YARMOUTH 31987 Bob Thomsen 04-19-22 √ √ √ √ Sean Skorohod CLOUDY √ √ √ NA