Loading...
HomeMy WebLinkAboutEngineer Certification Letter SWEETSER ENGINEERING 203 SETUCKET ROAD - P.O. BOX 713-SOUTH DENNIS -MASSACHUSETTS 02660 TEL (508) 385-6900 FAX (508) 385-6991 LAND SURVEYING - ENGINEERING - TITLE 5 SEPTIC SYSTEMS August 27, 2020 Mr. Bruce Murphy,Health Agent Yarmouth Health Department 1146 Main Street South Yarmouth, MA 02664 RE: Septic system @ 26 Minden Lane, Yarmouth File#2849-00 Dear Bruce, Earlier this week we staked the leaching facility at the above address and confirmed the contractor had lowered the foundation at least 2'. Leaving the components in their relative positions, the inverts were recalculated to insure proper flow. Today a visual fmal inspection of the septic installation was done. At the time of inspection these items were noted: 1. The installer placed a Zabel Filter in the outlet tee instead of the gas baffle. 2. The d.box&leaching galleys were upgraded to H-20 loading. 3. The tee in the d.box was missing,I mentioned this to the installer and he stated he would install before backfilling. 4. Although unnecessary, a vent was added. 5. The system needs to be carefully backfilled and graded With those noted above,the system appears to be installed in substantial compliance with the approved plan dated December 16, 2019. The installer, Sweeney Excavation was informed they need to supply you with"As-Built"cards. If you have any questions or concerns,please call. Very t• y yours .400, Robin W. Wilcox, SI LOLL HEALTH DEPT.