August 27, 2020
Mr. Bruce Murphy,Health Agent
Yarmouth Health Department
1146 Main Street
South Yarmouth, MA 02664
RE: Septic system @ 26 Minden Lane, Yarmouth
File#2849-00
Dear Bruce,
Earlier this week we staked the leaching facility at the above address and confirmed the
contractor had lowered the foundation at least 2'. Leaving the components in their relative
positions, the inverts were recalculated to insure proper flow.
Today a visual fmal inspection of the septic installation was done. At the time of inspection
these items were noted:
1. The installer placed a Zabel Filter in the outlet tee instead of the gas baffle.
2. The d.box&leaching galleys were upgraded to H-20 loading.
3. The tee in the d.box was missing,I mentioned this to the installer and he stated he would
install before backfilling.
4. Although unnecessary, a vent was added.
5. The system needs to be carefully backfilled and graded
With those noted above,the system appears to be installed in substantial compliance with the
approved plan dated December 16, 2019. The installer, Sweeney Excavation was informed they
need to supply you with"As-Built"cards.
If you have any questions or concerns,please call.