Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. b V Lot Zone of Contribution: In Out' Acreage_ 0 Commercial: Residential: Street: 5 Q / L)i i S/O w 5 rc:.. I . Village: ( Floor Plan: !� #Bedrooms: 3 Owner: /�L,r f 1/3rincl✓� de rhe(- Installer: /C_- Address: Address: Phone: 7'7' - 3 5 3 " f 9 Phone: 7 2 L/ - 'x,51 - G 'to / Builder: Engineer: L:Cu - /c-c:4 Address: Phone: ,5-..2g 36e//- o �9 Phone: N/A YES _....., NO 1. Required#of copies received t/ 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material, above water table I./ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,� 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands , 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 1.." v 9. Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: iZ 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: c/ 15. System not in top or subsoil(A,B horizons)or 5' removal 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred C/ 18. System meets breakout requirements PVC liner: Wall: �' 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal !V/ 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox !L/ 24. Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes i7:/ 27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber / / 31. Engineer to inspect and certify soils: wall: commercial: f/ 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,/ 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature / 35.Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd V 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: ��./yb60 a o.;n f