Loading...
HomeMy WebLinkAboutEngineer Plan--64-- EXISTING CONTOUR'° x 60.98 EXISTING SPOT GRADE r S)!IAN gtc�i4._ -W- EXISTING WATER SVC.'r, -G- EXISTING GAS SERVICE '� '•(� -- s -O.H.W.- OVERHEAD WIRES X IS TEST PIT 99.74 X / 1 97,5 •� BENCHMARK LEGEND PROPOSED SEPTIC TANK 5$�6 pp 1500 GALLON CAPACITY �o 99.54RESERVE AREA)•✓` 46 sr, REQUIRED LOCUS g pO• 'S rP G�/�, jo N RECEIVED X 100 x 96;20 2 Selene Pond x 9s.74 ,�s MAY 0 2 2022 LOCUS MAP SHED I m DEPT. 100 7 x 9731a HLo HEALTH IRON PI EXISTING CESSPOOL 10o,9a 101.75 x 0-f/W,, 101.62 G X98.07 19 TO BE PUMPED, FILLED GENERAL NOTES: 99 28 y,- I 9 WITH SAND & ABANDONED p y ,76 t `� 6.66 (SEE NOTE 14) 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. \�- EXISTING 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS 10 23 SNC W PROPOSED HOUSE&20) x 96�5� OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE G � IN E i � LOCAL RULES AND REGULATIONS. YtrmOttb g/tltb Deptrbwa SGS �P T.O.F.•=101.4± N=�u .. EL. 102.12 97,15` x:. 9f��5 - �iRO THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE \� 952 DESIGN ENGINEER. a v' -� 10 \ x =.7;'. (V ^� o m r O �Jj//� �� �� AroA ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING �!Atf 9870 ��'' S x 100.62 92 O �`'' \96.14 FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. DEC �!l/�' 'S� L.,. S. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. ., ry \x9858 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF x 01.941 x 048 x q 96 20 �/ LOT` l0 '� 95,70 THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 9 49 10,WAS.F. ;. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVIC . � j 9&- - 1 '\ 0 "'� 3j� _. 0 �,p �' �p `.,';A�� 95.25 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL CLEARED O h.•`.. .,•".�� 98186 g6 x AREAS FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE 97.84 x 1 )1.10 ��G � 5$ 100.00 / DIRECTED BY THE APPROVING AUTHORITIES. 101.69 x > �6 ,' ,� �('� \ ► 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY 9654 Y THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 97,36oVe /IRg- P YYY 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 07' ,,� o i IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND PROPOSED S.A.S. ?2 --00, .'edge '( 96.92 \ .MAS REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 5 LC -6 UNITS SURROUNDED ,('( 1 OF N P 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL, WITH 3.5' OF STONE, ALL SIDES ^ �U 96.95 3� y r PETER T. GI 13. THIS PLAN IS. TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND 96.90 �-1 1V, McENTEE NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC CIVIL "' No. 35109 SYSTEM COMPONENTS NOT SHOWN ON THE PLAN B C /V BOTTOM K .96.58 M STEP cI ° MAP ID: 49-238 EL =96.58 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 5z� 20 ROBIN ROAD, WEST YARMOUTH, MA FLOOD ZONE DESIGNATION FLOODMAP: 250010587) . Prepared for: Quinn's Excavation, P.O. Box 499, Forestdale, MA 02644 MAP REVISED: JULY 16, 2014 ZONE AE(EL 11) & 0.2% ANNUAL CHANCE OWNER OF RECORD Engineering by: SCALE DRAWN JOB. NO. JULIA PEngineering Works, Inc. 1 "=20' P.T.M. 166-22 PLAN REFERENCES RANDALES, EVE YN PLAN BOOK 144 - PAGE 123 20 ROBIN ROAD 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. CERTIFIED PLOT PLAN BY ROBERT ELDREDGE, DATED 8/19/77, F EASED 9/11/78 WEST YARMOUTH, MA 02673 (508) 477-5313 4/25/22 P.T.M. 1 Of 2 �( NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 98.1 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET S INSTALL RISER AND COVER INSTALL RISER & COVER OVER ONE CHAMBER(MIN.) OUTLET AND SET TO 6" OF FINISH GRADE SET TO WITHIN 6" OF FINISH AND SET TO WITHIN 3" OF FINISH GRADE TO SERVE .EXISTING T.O.F.=101.4± GRADE _ - AS AN INSPECTION MANHOLE. HOUSE(20) F.G. EL.--100.3±F.G. EL =101.0± (CUTTING GRADE DOWN) T.O.F.=101.4f EXISTING F.G. EL.=100.6± F.G. EL=101.Ot,' 162.'12' L = 10' 0 S=1% (MIN.) L = t' L - 16' 4"SCH40 PVC 4 S=17 • 4"SCH " (MIN.) 0 S=1% (MIN.) PVC 4"SCH40 PVCdL - - 2" LAYER OF 1 8" s TO 1/2 DOUBL� 44.8' T •+ 14^ 12" I I WASHED STONE o' / INV.=96.60 48" LIQUID INV.=9 APPROVED FILTER FABRIC) '� 'jQ•�^ �� ry� LEVEL BAFFLE NV. .35(OR PROPOSED INV.=97.80 3.5' 3' 3.5' 3/4"-1 1/2' 7.97 EFFECTIVE WIDTH = 10' DOUBLE WASHED H-10 RATED INV.=97.60 STONE ( PROPOSED S.A.S. 3> PROPOSED SEPTIC TANK USE 5 LC -6 LEACHING CHAMBERS IN SERIES WITH 5 LC -6 UNITS SURROUNDED '0' 3.5' OF DOUBLE WASHED STONE ON ALL SIDES WITH 3.5' OF STONE, ALL SIDES CONNECT TO NEW SEWER OUTLET AT H-10 RATED HOUSE, AT, OR ABOVE, INV.=96.70 I SYSTEM LOCATION NOTES: TOP CONC. ELEV.=98.43 i - BREAKOUT INV. ELEV.=97.60 ELEV.=98.1 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE ,,, I E3 Ea E3 E31 INVERTS, PRIOR TO INSTALLATION. BOTTOM ELEV.=96.60 2) D -BOX SHALL BE SET LEVEL AND TRUE TO 3.5' 5 x 6' = 30' 3.5' GRADE ON A MECHANICALLY COMPACTED SIX 4 INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 310 CMR 15.221(2). OF NATURALLY OCCURRING -" PERVIOUS MATERIAL EFFECTIVE LENGTH = 37 5' MIN. ABOVE G.W. r--`-_ --- --------- --------� 4 KNOCKOUT I 20' 0P. COYER 3) INSTALL INLET & OUTLET TEES AS REQUIRED. EST. GROUNDWATER, EL=91.6 LEACHING SYSTEM SECTION I iIGH 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE = _ m AS MANUFACTURED BY TUF-117E, ZABEL OR EQUAL. a KNOCKOUT 4• KNocKour "' SEP IC SYSTEM PROFILE I I I I 4' KNOCKOUT N.T.B. r 72" 1 DESIGN CRITERIA SOIL LOG PLAN VIS NUMBER BEDROOMS: 2 BEDROOMS, DESIGN FOR CLASS I 3 DATE: APRIL 13, 2022 SOIL EVALUATOR: PETER McENTEE SE#1542. _ r------- ------ r- py -� ® ® ® 0 ® ® ® ® 0 U SOIL TEXTURAL CLASS: DESIGN PERCOLATION RATE: <2 MIN/IN WITNESS: JAY GARDINER HEALTH AGENT ELEV. TP DEPTH T 2Y• IN ZRr� ®®®®®®® DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO -AND NOT PERMITTED WITH ESIGN 99,5 A 0" LOAMY SAND 1OYR SAN 98,9 7" LOAMY SAN PERI 10YR 5/8� 20" - I I 72' , r 3'• 1 SIDE VIEW END VIEW WIGGIN LC -6, H-20 LOADING ) LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 74 GPD/SF 97.3 26" LEACHING CHA PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY, H-10 RATED C PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLET , H-10 RATED M -F SAND N.T.S. PROPOSED SEPTIC SYSTEM UPGRADE PLAN USE -s LEACHING CHAMBERS IN SERIEz.SY 5/3 3.5' of DOUBLE WASHED STONE ON ALL SIDES SOILS SHALL BE VERIFIED AT REDOX OF POPEDURINGS 91.6 ADJ. GW 95"7 5 YR 5/8 20 ROBIN ROAD, WEST YARMOUTH, MA SIDEWALL AREA: (10.0' + 37.0') x 2 x 1' = 94.0 SF BYCDEISIGN ENGIN EER DLOATON INSTALLATION 90.9 103" STG. GW Prepared for: Quinn's Excavation, P.O. Box 499, Forestdale, MA 02644 BOTTOM AREA: 10.0' x 37.0' = 0.0 SF Engineering b 9 9 Y SCALE DRAWN JOB. NO. 6 90.5 108' TOTAL AREA:................................................. .......... 4.0 SF PERC RATE <2 MIN/IN. "B" HORIZON Engineering Works, Inc. NTS P.T.M. 166-22 DATE CHECKED SHEET N0. DESIGN FLOW PROVIDED: 0.74 GPD/SF(464.0 SF) =343.4 GPD STANDING GW, EL. =90.5 12 West Crossfield Road, Forestdale, MA 02644 ESTIMATED HIGH GW, EL.=91.6 2DOX) (508) 477-5313 4/25/22 P.T.M. 2 Of 2