HomeMy WebLinkAboutNat Grid ltr gas main abandonment 40 Sylvan Road Waltham, MA 02451 www.nationalgrid.com May 5, 2022 Yarmouth Conservation Commission 1146 Route 28 South Yarmouth, MA 02664 RE: Proposed Gas Main Abandonment 297-301 South Shore Dr South Yarmouth, Massachusetts Dear Commissioners: Boston Gas Company (BGC) is submitting this written notification of the intent to conduct Public Utility Maintenance Activities (gas main installation) off South Shore Dr, Yarmouth, MA. The proposed gas maintenance project is being conducted to improve customer reliability of local natural gas utility services. The project includes the replacement of approximately 315 linear feet of steel gas line with plastic gas line. The existing gas lines will be capped and abandoned in place and the replacement gas lines will be installed adjacent to the abandoned gas line. The utility maintenance activity will be located within the 100-foot buffer zone to coastal resources and Land Subject to Coastal Storm Flowage (LSCSF). The project will not impact wetland resource areas and all proposed work will occur within the roadway. Best Management Practices (BMPs) will be implemented during the proposed project, as needed (please see example BMPs attached). During construction, a 3±-foot wide trench will be excavated to install the gas line with the precise location of the trench and gas line determined in the field so that existing utility and drainage structures can be avoided. Work as proposed will be temporary in nature and following work, pre-existing conditions (e.g., grades, vegetation, and pavement) will be restored. According to the Wetlands Protection Act, activities conducted to maintain, repair or replace, but not substantially change or enlarge, an existing and lawfully located structure or facility used in the service of the public and used to provide electric or gas services are exempt from regulation under MGL 131, 40, provided said work utilizes the best practical measures to avoid or minimize impacts to wetland resource areas outside the footprint of said structure or facility (310 CMR 10.02(2)(a)(2)). Please refer to the attached Site Maps for the approximate project location and do not hesitate to contact me at 978-551-1156 if you have any questions or require further information. Respectfully, National Grid Jaime Walker Environmental Scientist Attachments: Site Maps Sample BMPs SITE MAPS Copyright:© 2013 National Geographic Society, i-cubed DATE: 05-05-2022 W/O or W/R: SOURCE : THIS MAP CONTAINS THE ESRI ARCGIS ONLINE USATOPOGRAPHIC MAP SERVICE, PUBLISHED DECEMBER 12, 2009BY ESRI ARCIMS SERVICES AND UPDATED AS NEEDED. THISSERVICE USES UNIFORM NATIONALLY RECOGNIZED DATUMAND CARTOGRAPHY STANDARDS AND A VARIETY OFAVAILABLE SOURCES FROM SEVERAL DATA PROVIDERS. Data Supplied by : 402,000 4,000 6,0001,000 SCALE IN FEET © 2022 - TRC Environmental, C:\Users\jwalker\OneDrive - TRC\Desktop\Site Locus Maps\SiteLocus_SShoreDr_Yarmouth.mxd, 5/5/2022, 2:39:20 PM, JWalkerSITE LOCUS MAP PROPOSED GAS MAIN ABANDONMENTSOUTH SHORE DRYARMOUTH, MASSACHUSETTS 1447446 FIGURE 1 Copyright:© 2013 NationalGeographic Society, i-cubed 1 297-301 South Shore Dr, Yarmouth, MA Gas Main Relay Erosions controls to include straw wattles as appropriate and silt sacks in catch basins along work route. SAMPLE BEST MANAGEMENT PRACTICES 1 2 3 ENVIRONMENTAL GUIDANCE Date Doc. No.EG-303NE 02/20/18 SUBJECT Access, Maintenance and Construction Best Management Practices Reference EP No. 3 - Natural Resource Protection (Chapter 6) Rev. No. 4 SEC-5 STRAW WATTLE * (1 OF 2) BMP DETAIL Page: 7-5 ENVIRONMENTAL GUIDANCE Date Doc. No.EG-303NE 02/20/18 SUBJECT Access, Maintenance and Construction Best Management Practices Reference EP No. 3 - Natural Resource Protection (Chapter 6) Rev. No. 4 SEC-5 STRAW WATTLE * (2 OF 2) BMP PICTURE Page: 7-6