HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot 7 Zone of Contribution: In Out Acreage 7 448 7
? Commercial: Residential:
'
Street: g 1 , / / ! t3 tv ri
Village: / Floor Plan: #Bedrooms:
Owner: Er l o N S ! l D A. i Installer: ��i k 13 0..5 e 711 /
Address: Phone:
Phone:
Builder: Engineer: 3 S C
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received ,✓
2.Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: ✓
6. Benchmark indicated and shown-NGVD if near wetlands ,•
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.:
11
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", %"preferred -
18. System meets breakout requirements PVC liner: Wall: M-
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel L./
21.No garbage disposal
22. System adequately sized for its intended use ✓
23.Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade,pump chamber cover to grade t-----/
25. Inspection port on plastic chambers/leach field tJ
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size V
28. Septic tank/pump chamber to be factory waterproofed /
29. Vent provided if leaching below 3 feet,under driveway/parking t/..
30. Buoyancy calculations for tank/pump chamber /
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature /
33.H-20 loading is subject to vehicular traffic, groundwater ,/
34.Title V Application and permit fee, installer signature t/
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by:
6030;