HomeMy WebLinkAbout2018 Sign off Transmittal - New 3 br home ok TOWN OF YARMOUTH
if ! k- HEALTH DEPARTMENT
;'' PERMIT APPLICATION SIGN OFF TRANSMITTAL SHEET
To be completed by Applicant: ( f 7 It's 9' c
Building Site Location: bag
Propose Improvement: A _ C' / ��. i 4
Proposed
•
Applicant: Ani-h02.9 DIS p/! Tel. No.: (a-7.---c7?/.3 - 7ad
Address: 534 A/ Tl-h \S"-* waJ/b LQ, /1 02C Date Filed: 03,MO)E
**lf you would like e-mail notification of sign off please provide e-mail address: a/?f)70t j ?L)S/P/c e CO)7-)Owner Name: � ��`� tL'& D/Sip/e
CJ� / // 7)74 02()£/
Owner Address: 530 /Voi _ wa 1190 rG Owner Tel. No.:6/ j d 9-3 -72U.
RESIDENTIAL AND/OR COMMERCIAL BUILDING
HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e., Requirements
For Septage Disposal and other Public Health Activities.
Please submit three (3) copies of plans, to include:
(1.) Site Plan showing existing buildings, water line location,
and septic system location;
(2.) Floor plan labeling ALL rooms within building
(all existing and proposed) —
Note: Floor plans not required for decks, sheds, windows, roofing;
(3.) If necessary, Title 5 application signed by licensed installer
with fee.
REVIEWED BY: �7 ski' DATE:
PLEASE NOTE •
COMMENTS/CONDITIONS; '
71/ 'g:f i16 1`i /
Vii:►, r�
•
/d . MIPMEZ,
he /N r ki/
SYSIEMQ PROFILE
(NOT TSCALE)
ACCESS COVERS TO WITHIN 6" OF FIN. GRADE
EL. 13.5'**
ALL SYSTEM COMPONENTS SHALL BE
MARKED WITH MAGNETIC TAPE OR
COMPARABLE MEANS FOR FUTURE LOCATION.
2% SLOPE REQUIRED OVER SYSTEM 111.4
0 PRECAST H-10
RISERS (TYP.) 4"O CH40 PVC /
O Q PIPS LEVEL IST 2' 2" DOUBLE -WASHED PEASTONF/�
Oce JPO
OR GEOTEXTILE FABRIC
1500 GAL H-10 14. 10.66'
10" Ll
6 1
1 0.74' TEE SEPTIC TANK TEE , o 0 0°°00 0 o 0 0 0 000o°°o°a a°o°eo°° 0°0°000°0000°
10.49 °°° 10.16, °,,o,o,o,°,°,°°,°,°,°,gog°aooao °eog0,00°0°
°0°0°O °°° ° U ° °.0.. °°° ° o ° o O ° ° o C C °
0 0 0°° o o°o o° o 0 0°°°
° ° ° o ° ,
°o 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
GAS BAFFLE '-0°°°o°°o°°o°°o°o°0°0°0°0°000°°°0°0°0 0 o°c°o° °o°o°o°°o°°o°o°o° 9.5
4' LIQ. LEVEL (ACME OR EQUAL) .'; 1 0.36' 10.1 9' 4" PVC SET AT .005'/' SLOPE
'�,` .-,.. ,...-.: ON 6" DOUBLE WASHED 3/4"- 1 1/2" STONE
"$°$°$°$°0°o°8°i;°o°°°°°S°o°o°o°oo8go°o°S°°°a WATER- EST D'BOX FOR LEVELNESS
°0°0°0°000°o°o°u,00oo00oo0o0r4r°n_0_°o00°000.
5'
6" CRUSHED STONE OR MECHANICAL
COMPACTION. (15.221 [21)
(2 % SLOPE) (--L% % SLOPE) (� % SLOPE)
13' D' BOX 5' LEACHING USE ADJ. G -W ®4.5'
FOUNDATION- 16' -SEPTIC TANK
FACILITY
*THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL
UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS
PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM #2
**MIN ELEVATION TO PROVIDE GRAVITY FLOW AND HOLD
MINIMUM 5' SEPARATION TO ADJUSTED GROUNDWATER
.LEGEND-
EGEND99-
99-
EXISTING CONTOUR
X 99.1
EXIST. SPOT ELEV.
F9_91
SOILS
SYSTEM DESIGN:
PROPOSED CONTOUR
F99-1
PROPOSED SPOT EL.
TTH 11
10.0' 0"
10.0'
TEST HOLE
2YYYY>
SLOPE OF GROUND
�Q-)
UTILITY POLE
Y
FIRE HYDRANT
NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING
TEST HOLE LOGS
ENGINEER: DAVID FLAHERTY, R.S.,
WITNESS: PHIL RENAUD, YBoH
DATE: 12/18/06
SE2755
PERC. RATE _
< 2 MIN/INCH
CLASS I
SOILS
SYSTEM DESIGN:
4
ELEV.
ELEV.
0"
10.0' 0"
10.0'
A
S sf
DESIGNFLOW: 3 BEDROOMS ® 110 GPD
LS
s
FlOYR
1OYR 5/4
SPECIFICATIONS OF 310 CMR 15.255(3)
5/4
11"
9"
O/00
B
°*
�
B
LS
1
LS
1OYR 5/8
35'
7.08' 36"
1OYR 5/8
7.0'
C
PERC C
057"
FMS
FMS
93" OBS WATER 2.25' 94" OBS WATEF
2.5Y 6/4 2.5Y 6/4
108" 1.0' 108"
G -W ADJ. DATA:
WELL: MIW 29
ZONE: BORDER A/B
ADJ: 1.9'/2.8' (AVG. 2.3')
13-184
#4
10/17/13
D. GONSALVES, SE
WITNESS: B. MURPHY
& P. RENAUD
EmE ELEV.
0" 9.0'
A
LS
8° 1OYR 4/2
B
LS
1OYR 5/6
22" 7.17'
C
WATERLINE
OPO
PROP. DWELL.
TOP FNDN. = 12
(SLAB FOUNDAT.ON,
CRAWLSPACE)
NOTES
1. DATUM IS NAVD 88
2. MUNICIPAL WATER IS PROPOSED
3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT.
4. DESIGN LOADING FOR ALL PROPOSED PRECAST
UNITS TO BE AASHO H-10
5. PIPE JOINTS TO BE MADE WATERTIGHT.
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE
WITH 310 CMR 15.000 (TITLE 5.)
7. THIS PLAN IS FOR PROPOSED WORK ONLY AND
NOT TO BE USED FOR LOT LINE STAKING OR ANY
OTHER PURPOSE.
8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC.
9. COMPONENTS NOT TO BE BACKFILLED OR
CONCEALED WITHOUT INSPECTION BY BOARD OF
HEALTH AND PERMISSION OBTAINED FROM BOARD
OF HEALTH.
10. CALLINGTD GSAOFE (1-888-344-7233) LL BE E 0BLE ANDFOR LOCUS MAP
VERIFYING THE LOCATION OF ALL UNDERGROUND &
OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF NOT TO SCALE
WORK. ASSESSORS MAP 22 PARCEL 215.2
11. ANY UNSUITABLE MATERIAL ENCOUNTERED LOCUS IS CURRENTLY WITHIN FEMA FLOOD ZONE
SHALL BE REMOVED 5' BENEATH AND AROUND THE AE (EL 11) AS SHOWN ON COMMUNITY
PROPOSED LEACHING FACILITY. PANEL#25001CO588J DATED 7/16/2014
12. WETLAND FLAGGED BY HAMLYN CONSULTING ZONING SUMMARY
ZONING DISTRICT: R-25 DISTRICT
MIN. LOT SIZE 25,000 S.F.
MIN. BLDG COVERAGE: 25%
MIN. FRONTAGE 150'
MIN. FRONT SETBACK 30'
MIN. SIDE SETBACK 15'
MIN. REAR SETBACK 20'
- PROVIDE EROSION CONTROL BARRIER (HAY WATTLES)
SITE IS NOT WITHIN APD
Route
e
SYSTEM DESIGN:
c 0
GARBAGE DISPOSER IS NOT ALLOWED
O �7P
3
S sf
DESIGNFLOW: 3 BEDROOMS ® 110 GPD
'-
s
USE A 330 GPD DESIGN FLOW
SPECIFICATIONS OF 310 CMR 15.255(3)
O/00
°*
�
1
e
'. PROVIDE 90' OF 40 MIL
0
Lewis
° °
Lewis
Bay
BOTTOM 30 x 15 (.74) = 333
Pond
10.7', BOTTOM AT EL. 6.7'f
Radio
_
Owers
TOTAL: 450 S.F. 333
GPD
10. CALLINGTD GSAOFE (1-888-344-7233) LL BE E 0BLE ANDFOR LOCUS MAP
VERIFYING THE LOCATION OF ALL UNDERGROUND &
OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF NOT TO SCALE
WORK. ASSESSORS MAP 22 PARCEL 215.2
11. ANY UNSUITABLE MATERIAL ENCOUNTERED LOCUS IS CURRENTLY WITHIN FEMA FLOOD ZONE
SHALL BE REMOVED 5' BENEATH AND AROUND THE AE (EL 11) AS SHOWN ON COMMUNITY
PROPOSED LEACHING FACILITY. PANEL#25001CO588J DATED 7/16/2014
12. WETLAND FLAGGED BY HAMLYN CONSULTING ZONING SUMMARY
ZONING DISTRICT: R-25 DISTRICT
MIN. LOT SIZE 25,000 S.F.
MIN. BLDG COVERAGE: 25%
MIN. FRONTAGE 150'
MIN. FRONT SETBACK 30'
MIN. SIDE SETBACK 15'
MIN. REAR SETBACK 20'
- PROVIDE EROSION CONTROL BARRIER (HAY WATTLES)
SITE IS NOT WITHIN APD
AT ROAD RIGHT OF WAY IN AREA SHOWN (APPROX.
115')
SYSTEM DESIGN:
GARBAGE DISPOSER IS NOT ALLOWED
5' REMOVAL OF UNSUITABLE SOIL REQUIRED
AROUND PERIMETER OF LEACHING FACILITY,
SOIL LAYER. REPLACE
DESIGNFLOW: 3 BEDROOMS ® 110 GPD
= 330 GPD
DOWN SUITABLE
AN MED. SAND, TO MEET
WI -
NTH CLEAN
USE A 330 GPD DESIGN FLOW
SPECIFICATIONS OF 310 CMR 15.255(3)
SEPTIC TANK: 330 GPD (2) = 660
1
USE A 1500 GAL. SEPTIC TANK
'. PROVIDE 90' OF 40 MIL
LEACHING:
/ LINER AT 5' OFF SAS IN
SIDES:
N/A
AREA SHOWN. TOP AT ELEV.
BOTTOM 30 x 15 (.74) = 333
GPD
10.7', BOTTOM AT EL. 6.7'f
_
TOTAL: 450 S.F. 333
GPD
J `0 V
\ o
USE 30' x 15' x 0.5' DEEP LEACH FIELD WITH (3) 4"
9�
PERF. PVC IN DOUBLE WASHED STONE.
SEE DETAIL
tX
1.4 `UTIL POLE
MS G -W ADJ. DATA (AH):
WELL: MIW 2
ZONE: BORDER A/B LOT AREA:. /1
10YR 7/4 ADJ: 2.5'/3.1 (AVG. 3.1') 8,329 SF
2.17 94" OBS WATER 1.17'
PROVIDE DRYWELLS FOR ALL ROOF RUN-OFF
SHED
1.0' 96"
Scale:1 "= 20'
0 10 20
40 50 FEET
DECK
EXISTING
DWELLING
2 -$�,
DATE
BENCHMARK: USE MAG NAIL AT
ELEVATION 9.98' NAVD88
Yarmouth Health Department
_ ., APP LOVED
UANILL A. UJALA, H.L., ]'.L.J.
, MA
APPROVED DATE BOARD OF HEALTH
TITLE 5 SITE PLAN
OF
47 FRANKLIN ST. EXT.
WEST YARMOUTH
PREPARED FOR
ANTHONY DISIPIO
DECEMBER 26, 2013
REV. 1/27/14 (NO FILL)
REV. 2/3/14 (FILL)
REV. 2/25/14 (WATTLE)
REV. 2/29/16 (NAVD 88 DATUM)
I off 508-362-4541
fax 508-362-9880
downcope.com
down cape eagineefing, kC.
civil engineers
land surveyors
939 Main Street ( Rte 6A)
YARMOUTHPORT MA 02675