HomeMy WebLinkAboutEnggineer PlansALWAYS DIG SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOME CAUTION: THIS IS A SITE PLAN SURVEY BY THIS OFFI AND NOT A COMPLETE PROPERTY LINE SURVEY. LOT LINES SHOWN ARE APPROXIMATE. 0 Wwo RAISE GRADE OVER 18" J- � IN PROPOSED LEACH AREA am 3 3' DEEP IMPERVIOUS BARRIER --130 L.F. OF 40 MIL POLYETHYLENE T(MILLER OPBARR ER BREAKOUT") **) PEASTONE=20.6, GRADE ABOVE BARRIER=21.0 MIN ** BARRIER IS STIFF & OBTAINABLE FROM MILLER ENVIRONMENTAL 508-697-3710. BENCH MARK --TOP OF WOOD (3, STAKE = 20.00 ASSIGNED (28'-6" OFF CORNER GARAGE) N/F NICHOLSON N/F ACETO 19.8 . 18.6 9,0 �' LOT 57A G 12. FOANAOVE DCT EGBISACALLLED FOR BELOW,RD I OF HEALTH, OR ILLJ. CMAITERIAL FOR 5' AROUND AND UNDER LEACHING 6' \ �� IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 18.7 8700 S. F. O. 4 13. PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN 9 LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14 ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS �� 0 5P P9:6g� Inv. 18.2 Proposed X19 J� 0. 9\101I z y' t9. 20.6 N/F JOHNSON MONOLITHIC 1000 GALLON H-10 PUMP CHAMBER DRILL 3/8" WEEP/VENT HOLE Recommend Floats re lacable from to Invert On22" Off 17" 12.40 Quick Disconnect/ Union Check Valve NDER TH 1 _ JOB NO. Y04-07 --W- WATER LINE MARKINGS NOTES Nugent.dwg BENCH MARK -TOP OF MAG. NAIL Ro°d G< °y -G- SET IN PAVEMENT= .24 ASSIGNED 1. 1. LOCUS IS A.M. 48, PARCEL 97. ' 9.5 x 21,7 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) �e1 2. ELEVATIONS SHOWN ARE ASSIGNED. �`ns\°� n^ _g-- 3. LOCUS IS IN FLOOD ZONE B ON FIRM DATED JULY 2, 1992. Observed vWnzr=171 Q 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) UTILITY POLE (IF SHOWN) M 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. -- • -- FENCE (IF SHOWN, NOT ALL SHOWN) 9,01 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. ear LEACH AREA , ®7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". end• REQUIRED CAPACITY: 4 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW \ I i Proposed WATER PROOF D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. cv°� 1500 GAL. \ /']`\/ 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. 19.E NOT TO COVERS: BUILD UP COVERS TO 6" BELOW GRADE --2 ON TANK, 1 ON D -BOX, 1 ON LEACHING SCALE ON THE ENDS AND 4' STONE ON THE SIDES 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 9 21 11 IF UNSUITABLE SOILS OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND LOCATION MAP 9,0 �' LOT 57A G 12. FOANAOVE DCT EGBISACALLLED FOR BELOW,RD I OF HEALTH, OR ILLJ. CMAITERIAL FOR 5' AROUND AND UNDER LEACHING 6' \ �� IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). TEST HOLE 1 18.7 8700 S. F. O. 4 13. PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN 9 LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. DEPTH (inches) ELEV.(feet) 14 ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS �� 0 5P P9:6g� Inv. 18.2 Proposed X19 J� 0. 9\101I z y' t9. 20.6 N/F JOHNSON MONOLITHIC 1000 GALLON H-10 PUMP CHAMBER DRILL 3/8" WEEP/VENT HOLE Recommend Floats re lacable from to Invert On22" Off 17" 12.40 Quick Disconnect/ Union Check Valve NDER TH 1 LEGEND TEST HOLE LOCATION, NUMBER --W- WATER LINE MARKINGS E OVERHEAD ELECTRIC WIRES (IF SHOWN) -G- GAS LINE MARKINGS 9.5 x 21,7 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) FACTORY EXISTING CONTOUR _g-- PROPOSED CONTOUR Observed vWnzr=171 Q 0 UTILITY POLE (IF SHOWN) M EXISTING DRAINAGE CATCH BASIN -- • -- FENCE (IF SHOWN, NOT ALL SHOWN) GARBAGE GRINDER: TREE (IF SHOWN, NOT ALL SHOWN) FUTUR o ,USE 'y \� 9.4 8 OGiSj / TEST HOLE DATE: March 24, 2003 12" PERFORMED BY: Ron Cadillac, Soil Evaluator WITNESSED BY: David Flaherty, Jr., RS /19,4/ C / a /A PERC RATE: 1'-02"/inch (Cl layer) /vv// SOIL SURVEY(1993): Carver coarse sand 33" ... / 19.65± E GEOLOGIC MAP(1986): Harwich outwash plain deposits 19.5 8 • Top Block Found. Invert 17.98± invert 16.95 n Exist. PVC pipe Use Gas Baffle 4 CULTEC C-4 UNITS 48" invert 20.10 208 Proposed Proposed Top Regular Ston 21.3 9" e=20.56 min. cover d tall J i i 0o S=3/4 /I L MAKE See a No Peastone-Use Filter Cloth 4P inspection N/F74N/F I FACTORY LAND SURVEYOR & REGISTERED SANITARIAN Observed vWnzr=171 Q P.O. BOX 258 „ 20,5 Invert 17.20 1500 Gal. GARBAGE GRINDER: P LEACH AREA REQUIRED CAPACITY: ACETO I i Proposed WATER PROOF 1 Sanitary 1500 GAL. 3" A layer 10yr 3/3 sandy loom B layer 10yr 5/8 loamy sand C1 layer 10yr 5/6 loamy fine to med. sand C2 layer 2.5y 6/3 fine to med. sand 19.3 16.55 15.3 13.1 120 9.3 20.9 I I Bottom 12.70 Tee T Proposed Invert 20.27 Invert 20.109.85 6" 6" Stone or compact Proposed proposed 1 5 Bottom r 51- 12' r_3 ' 1 17 N i 01 I EI. 14.85 m 1.75' USGS Adjustment N/FDESIGN Using MASH29-March 04 DATA NALD J. CADILLAC, PLS, RS Zone A HODNETT LAND SURVEYOR & REGISTERED SANITARIAN Observed vWnzr=171 Q P.O. BOX 258 BEDROOMS:* 2 ACTUAL 0 WEST YARMOUTH, MA 02673 GARBAGE GRINDER: No LEACH AREA REQUIRED CAPACITY: 330 GPD 1 91DE BARRIER, OR 1 SEPTIC TANK: 1500 GAL. USE 4 CULTEC C-4 UNITS WITH 2' STONE H-20 TANKS BOTTOM LEACHING AREA: 432 SF ON THE ENDS AND 4' STONE ON THE SIDES FOR A 36' LONG BY 12' WIDE BY 3" DEEP [(36' X 12')] LEACH AREA. SIDE LEACHING AREA: 24 SF [21 36') X .25' DEEP)] 5' REMOVAL DESIGN CAPACITY: 337 GPD DO 5' ALL AROUND AND UNDER REMOVAL ALARM & PUMP NOTES [(432 SF + 24 SF) X .74 GPD/SF] DOWN 33" TO LOAMY FINE TO MED. SAND. 1. ALARM TO BE WIRED BY ELECTRICIAN ON PUMP CHAMBER STORAGE CAPACITY. 330 GAL. SEPARATE CIRCUIT FROM PUMP. DOSES PER DAY: > 4 BUOYANCY CALCULATIONS 1500 GAL. H-10 2. ELECTRICAL WORK TO BE INSPECTED BY WIRING INSPECTOR. *Design allows for future bath & bedroom in garage. WEIGHT OF EMPTY SEPTIC TANK AND 14" OF COVER 3. ALARM TO BE LOCATED IN HOUSE.TANK= BUOYANCY CALC'S-MONOLITHIC PUMP CHAMBER 5.74 TON (PER SHOREY) 4. PUMP TO BE CAPABLE OF PASSING 14" COVER=1.17' X 5.67' X 10.5' X 0.055 TON/CU. FT. 1-1/4" SOLIDS AND INSTALLED IN STRICT WEIGHT OF EMPTY CHAMBER AND 21" OF COVER 14" COVER=3.83 TON CONFORMANCE WITH MANUFACTURER'S CHAMBER= 4.15 TON (PER SHOREY) TOTAL= 5.74 TON + 3.83 TON = 9.57 TON SPECIFICATIONS. 21" COVER= 1.75' X 5.42' X 8.25' X 0.055 TON/CU. FT. WEIGHT OF WATER --HIGH GROUNDWATER DOWN 5. USE MEYER SRM4, 4/10 HP PUMP, OR 21" COVEII TON (14.85 -12.7) X 5.67' X 10.5' X 0.0312 TON/CU. FT. EQUIVALENT. TOTAL= 4.15 TON + 4.3 TON = 8.45 TON WEIGHT WATER= 3.99 TON 6. TO PROVIDE FOR EASY AND SAFE WEIGHT OF WATER --HIGH GROUNDWATER DOWN TANK AND 14" COVER ARE HEAVIER BY 5.5 TON. MAINTENANCE OF PUMP: (14.85 -12.40) X 5.42' X 8.25' X 0.0312 TON/CU. FT. -PROVIDE UNION/DISCONNECT IN 2" PVC LINE AT TOP PUMP CHAMBER SO PUMP WEIGHT WATER= 3.42 TON CAN BE REMOVED FROM TOP OF TANK. TANK AND 21" COVER ARE HEAVIER BY 5 TON. -RECOMMEND FLOAT BRACKET AT COVER SO SITE PLAN FLOATS CAN BE ADJUST./REPLACED FROM TOP. FOR THIS PLAN IS A VALID COPY ONLY IF IT BEARS MARK� � GEN AN ORIGINAL RED STAMP AND SIGNATURE. I t �I� 4�/atl & HEAI AGENT APPROVAL DATE LOT 57A, 7 M 2004 BY R.J. :UIT ROAD WEST, WEST YARMOUTH, MA 7, 2004 SCALE: 1 "=20' NALD J. CADILLAC, PLS, RS LAND SURVEYOR & REGISTERED SANITARIAN Q P.O. BOX 258 m wi� o 0 WEST YARMOUTH, MA 02673 (508) 775-9700 PAGE 1 OF 1