HomeMy WebLinkAboutEngineer PlanTOP OF END. EL. = 21.4 �F.G.EL: 19.60 F.G.EL• 16.0 TEE'S ARE T04E 14 4e SCH 40 P INV: 15.95 GAS J EXISTING O1111ET BAFFLE INV. 18.73 INV. 16.20sa PROP. 1,500 GALL014 SEPTIC TANK GAS BAFFLE TO BE NSTALLED ON OUTLET TEE AS MANUFACTURED BY NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE FINISHED ..• :. SLOPE OF c DOUBLE STONE•- �FILTER FABRIC • 4" SCH PVC ' Q �F. DEPTH 3/4" - 1-1/2• DOUBLE WASHED PROPOSED DB -3 4' 2 X 8.5' J, 4' DISTRIBUTION BOX - EFFECTIVE LENGTH = 25' (H20) INV. ELEV.= 13.20 s. OF K4s� M G BREAKOUT ELEV = 14 20 TUF-TITE, ZABEL, OF g JARREN EQUALE O MYER TOP CONC. ELEV.= 14.20 . • ; NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING � No. 1140 1 ®10 INV. ELEV.= 13.20rEFFECT PIPE INVERTS PRIOR TO CONSTRUCTION �p '�"GfSfE� 00®®®' 00®100 - 2) TANK/D-BOX SHALL BE SET LEVEL AND TRUE TO 00 GRADE ON A MECHANICALLY COMPACTED SIX `�NITARIP� - BOTTOM EL.= 11.20®® 5 FT. 3.75' INCH CRUSHED STONE BASE, AS SPECIFIED IN . 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ SEPARATION 5.67 FT. - WIDTH = 12.5' GAS BAFFLE AS REQUIRED SEPTIC SYSTEM PROFILE 4) ALL INTERIOR PLUMBING To BE COMBINED TO OUTLET BOTTOM OF TESTHOLE EL: 5.53 SOIL ABSORPTION SYSTEM (SECTION) SHOWN, PLUMBING PERMIT IS REQUIRED. (500 GALLON H-20 LEACH CHAMBER)', GENERAL NOTES: DESIGN CRITERIA S O i L LOGS 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAs. BOARD OF HEALTH AND THE DESIGN ENGINEER. NUMBER OF BEDROOMS: 3 BEDROOM DESIGN 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS DATE: MAY 23, 2020 SOIL TEXTURAL CLASS: CLASS I (0.74 GPD/SF) OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 DESIGN PERCOLATION RATE: <2 MIN/IN LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.4051 O: B WITNESS: MALLORY LANGLER, YARMOUTH HEALTH DEPT. DAILY FLOW: 1 110 G.P.D. X 3 BR = DESIGN FLOW: 330 G.P.D. 1) A 0.90 Fr. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING To BE 3.50 Fr (MAX) BEIDle GRADE VS RWD 3 Fr. (H20/VENT PROVIDED) TP- 1 GARBAGE GRINDER: NO not designed for garbage grinder) ( 9 9 9 9 ) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR17 Bev. Depth 20 0. _ SEPTIC TANK: 330 gpd x 200% - 660 gpd USE PROP. 1,5000 SEPTIC TANK TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. A LOAMY SAND LEACHING AREA REQUIRED:330 0.74 = 445.94 S.F. ( )/ 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN iCYR 4/i 1520 B LOAMY SAND 24" USE TWO (2) '.500 GALLON PRECAST H-20 LEACH CHAMBERS W/ 4' ENGINEER BEFORE CONSTRUCTION CONTINUES. BASED 13.20 1?7R 5/8 48" STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'D 5. ALL ELEVATIONS ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF C i BOTTOM AREA: 25 x 12.5 = 312.5 SF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. SIDE AREA : (25'. + 12.5. ) X 2 X 2 = 150 SF '.. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. MEDIUM SAND , 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED PERC TEST 2.5Y 7/3 TOTAL SQUARE FEET PROVIDED = 462 vs. 445.94 REQ'D TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. o Et. 11.90 DESIGN FLOW PROVIDED: 0.74(462 S.F.) = 342.25 G.P.D. vs. 330 G.P.D. req'd 9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING li CONSTRUCTION. 10. EXISTING CESSPOOL TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5. 5.53 140• PROPOSED SEPTIC SYSTEM UPGRADE PLAN - 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 122 BERRY AVENUE, WEST YARMOUTH, MA 12. THIS PUN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY PERC RATE <2 MIN/IN. (Cl" HORIZON) AND IS NOT TO BE CONSIDERED A PROPERLY LINE SURVEY NO GROUNDWATER OBSERVED Prepared for: Cape Cutham LLC Clifford Excavation 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. Design and Site Plan SCALE DRAWN DATE 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4' SCH 40 O 1/8 -/FT (UNLESS SPECIFIED) • I, Dvnen M. Meyer, RS., CSE, hereby certHy that I am currently approved by MADEP pursuant to 310 CMR 15.097 iby: , MEYER &SONS, INC. N.T.S. DMM O6/10�20 REV DATE CHECKED SHEET' N0. to canduct ea evaluations and that the above analysis has been performed by me consident with the 'm Pp BOX E48TSANDMCH, MA 02537 requirements M 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam October, 1999. 508352-2922 DMM 2 2 of