HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. '7-7 Lot I Zone of Contribution: In Out_ Acreage /5,2-S0 sa.-C-t-.
G Commercial: Residential:
Street: 03 Qvc.,, F'ex-ry)c ei .'__poi,J
Village: SjUhH A
- ,, YYvv.O LAA-L,_ Floor Plan: ../ #Bedrooms:
Owner: -5-2--fir v� a.ey `a, LI`S? t.„..)1 I`�o t••- Installer: go b�ex-f- g O v(' Ga ✓
Address: $3 Cla r-t-c.v rvl a.g-1--r R O t,J Phone: (Sps-6) 9-7-) -s c�-7
Phone: --- 5-45)- 7 J / - '7a 6 2.._
- C 0
O
7
Builder: Engineer: T. C. E{-taty�,�.:nq 1
Address: Phone: (SO)2'73. 03'7"7 J
Phone:
N/A YES/ NO
0N
1.Required#of copies received ,/
2.Date of soils exam and percolation test not older than 2 years ✓ U
(-A-1-
3.4-5 ft of naturally occurring pervious material,above water table ✓
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: t/ i Cv;)
5.Water line 10 ft from septic components Var.: t/ b Cn-
6.Benchmark indicated and shown-NGVD if near wetlands I ✓
7. Septic tank minimum 10 ft from foundation,deck Var.: ✓
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: S ' 6-1,4-A-- ...--
9.
9.Leaching minimum 100 ft from wetlands Var.: ✓
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓
11.Tank/leaching minimum 10 ft from property line Var.: V
12. System meets all other setback requirements Var.: V
13.Uses adjustment for maximum high groundwater Var.: V
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: V
15. System not in top or subsoil(A,B horizons)or 5'removal ,/
16.Proposed contours are suitable /
17. System meets slope requirements-min. 1/8", %"preferred
18. System meets breakout requirements PVC liner: Wall: / _
19. Specified tee sizes are proper, gas baffle on outlet tee V
20. Sewage is under 10,000 gpd for parcel f
21.No garbage disposal V
22. System adequately sized for its intended use 1/
23.Minimum 6"stone or compacted below tank and dbox V
24.Manhole covers within 6"of grade,pump chamber cover to grade ./
25. Inspection port on plastic chambers/leach field i
26. Electrical permit for pump chamber/Separate meter for duplexes ✓
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓
28. Septic tank/pump chamber to be factory waterproofed ✓
29. Vent provided if leaching below 3 feet,under driveway/parking ✓
30.Buoyancy calculations for tank/pump chamber / --
31.Engineer to inspect and certify soils: wall: commercial: I /
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V
33.H-20 loading is subject to vehicular traffic,groundwater s .
34.Title V Application and permit fee,installer signature
1 ✓
35.Foundation footing min.2 feet above adjusted ground water for new house I ✓
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: ( 1 6 03 03