HomeMy WebLinkAbout9 Holly Lane Air Leakage Report180 State Rd Suite 2U, Sagamore Beach, MA 02562 • 508-833-3100 • energycodehelp.com • info@energycodehelp.com
www.gocanvas.com 08B3944A-E107-446B-9A62-6DF06A1A0E3F
Duct Leakage Report
9 Holly Lane
Yarmouth
04/21/2022
Braga Brothers
2018 IECC Energy Code
Test Mode
Pressurization
Test Pressure
25.0 Pascals
Testing Equipment
Minneapolis
Total CFM@25
49.00
Total Square Footage
1631.00
Maximum Allowable Leakage
65.24
or Total Duct Leakage Percentage
0.03
HVAC Duct Test
180 State Rd Suite 2U, Sagamore Beach, MA 02562 • 508-833-3100 • energycodehelp.com • info@energycodehelp.com
www.gocanvas.com 08B3944A-E107-446B-9A62-6DF06A1A0E3F
Location Sqft Served Ring CFM@25 Gauge Duct Leakage %
Unconditioned
Basement
1631 C 49 0.03
180 State Rd Suite 2U, Sagamore Beach, MA 02562 • 508-833-3100 • energycodehelp.com • info@energycodehelp.com
www.gocanvas.com 08B3944A-E107-446B-9A62-6DF06A1A0E3F
All testing results recorded in this report
have been verified by:
Chris Mazzola
RTIN# - 8873503
ICC - 8344213
All testing was conducted in compliance with RESNET standards and protocols, the 780 CMR 51
Massachusetts Base Code, Stretch Code requirements and ASHRAE 62.2.