Loading...
HomeMy WebLinkAboutEngineer Plan1� x10- O 0 99.54 % 1 00 O xrbX'�(� 00. 1N ? 04 x m V-,r��''�}�, ' �. j1 .02 C rn �b,'q I SHED 100.24 0� x 100.35 BNC Ekt>AARK-2 CORNER STEP EL.=100.24 100.91 PROPOSED SEWER CONNECTION Aj 0 INV =99.04± (VERIFY) 100,76,..,1 x ¢; 7 tHw r NJ �Al o`'� �►��G NN ASs9� 3 dG Q CHURC LJR. o PETER T. w � ` McENTEE- 8116VIL N 31 Z -Z PROPOSED S.A.S. 4ROWS OF 5 HI—CAPACITY H-20 INFILTRATOR UNITS PROPOSED SEPTIC TANK INFILTRATOR IM1530(OR EQUAL) )0.32 pO S� V2 EXIST/NG CESSPOOL 10052, TO BE PUMPED & REMOVED 100. 9 -� ).8 B 00 3z, f II 1g��\� o ;4024 9935 pQ5 9935 LOT 152 x 6500 SF 9934 M m 99.67 PK SET - 99.63 99.57 OL edge A� 99 36 Y' I Z. i LEGEND III � -11-- EXISTING COTOUR x 100.98 EXISTING SPIT GRADE i r U —0. H. W..— OVERHEAD RES -- G EXISTING GA�: SERVICE y v r _W_ EXISTING WA" --R SERVICE ® * TEST PIT I ` �' v�V CUS ��„`��3 'r r iC BENCHMARK it Ti Ham_ ®P= 9957 Ifftx .".tdi ;4 a„s "max LOCUS MAP NOT TO .SCALE GENERAL NO ES: 1. ALL CHANGESTO'HIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALT AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS. OF THE STATE ENVI ONMENTAL CODE, TITLE V, AND ANY APPLICABLE- LOCAL RULES ANDIi EGULATIONS. - 3. THE SEWAGE DISP SAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AIX APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER 4. ANYCONDITIONS NCOUNTERED DURING CONSTRUCTION. DIFFERING FROM THOSE SHO NHEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORD CONSTRUCTIONCONTINUES 5. ALL ELEVATIONS ASED .ON ASSUMED DATUM. 6. THE DESIGN ENGIIkER IS NOT RESPONSIBLE FOR THE FAILURE -OF THE CONTRACTOR I R OWNER TO. NOTIFY THE LOCAL BOARD OF HEALTH .FOR PROVER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY P OVIOED BY TOWN WATER SERVICE. B. THERE ARE NO W LLS WITHIN 100' OF THE .PROPOSED S.A.S. 9. ALL AREAS CLEAN D FOR CONSTRUCTION SHALL BE RESTORED AS .AGREED UPON B ,OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THEM APPROVING AUTHORITIES. 10. IT SHALL BE THEJ{ RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION Of: ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION III 11, WHERE REQUIRECII CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE .AREA BENEATH AND. FOR 5' ON ALL SIDESOFTHE S.A.S AND REPLACE WITH CAN.SAND AS SPECIFIED IN 310 CMR 255(3):,. 12. AREAS REQUIRIN STRIPOUT OF .UNSUITABLE MATERIALS SHALL BE INSPECTED BY H LTH DEPARTMENT PRIOR TO BACKFILL 13. THIS PLAN IS Tdl BE. USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY .LINE SURVEY. 14. THE ENGINEER ISI NOT. RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPO NTS NOT SHOWN ON THE PLAN. 1�5. THE PROPERTY NOT WITHIN A. STATE REGULATED ZONE II. 4AP ID: 22-369 ,E?ROPOSED SEPTIC SYSTEM UPGRADE PLAN 33 MAINE AVENUE, WEST YARMOUTH, MA Prepared for: Cape Codl1 Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineers: Englneeling Works, Inc. 12 West Crossfield Road Forestdole, MA 02644 (508) 477-5313 Surveyors: IkEngineering, Inc. 1854 .Cranberry Hwy. Wareham, MA 02538 508):273-0377 SCALE 1 ”=20' DRAWN -P.T.M. JOB. NO. 188-22 OWNER OF RECORD 'BROWN ELAINE TRS .THE 33 MAINE AVE NOMINEE TRUST 120 TIDEVIEW DRIVE • DOVER, NH 03820 DATE.' 5322 � :CHECKED 'P.T.M. SHEET N0: _1 Of.2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL=98.33 r FOR A DISTANCE OF 15' AROUND THE / PERIMETER OF THE S.A.S. SEPTIC TANK MAY 2 3 2022 ��� INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX PROPOSED S.A.S. 66 ��pT OUTLET AND SET TO 6" OF FINISH GRADE T.O.F.=101.8± INSTALL RISER & WATERTIGHT INSTALL INSPECTION PORT OVER ONEH ROW(MIN.) COVER SET TO 6" OF GRADE F.G. EL.=100.0± A. ��q, HEALTH� 68.0' FG EL EL.=100.81 EXISTING /-F.G EL=100.51 F.G. EL=100.0± 71 / MAINTAIN 2% GRADE MIN. OVER S.A.S.' L..= 78, W=.a. ..�Ae. L -.:3; ..., INSPECTION L 9' m ® S=1% (MIN ) @ 4"SCH40 PVC TOP OF: TANK -99.35 4 = :. .PORT =1% MIN. _ ( ) _ CH40 PVC ®S 1% (MIN.) 4'SCH40 PVC s 9. •�, ( P. / 00 m 14 a 11" TOINV 44"LIQUID LEVEL RT ADD '. GASBAFFLE I V.=98.17 PROPOSED INV.=98.00 r 4 ROWS OF 5 UNITS AT 6.25'/UNIT =.31.3' -� I EXISTING 807. OF TANK=94.81 - V.=98.50 D -BOX INV.=97.94 SOIL ABSORPTION SYSTEM (PROFILE) PROPOSED S.A.S. HOUSE 1,33) PROPOSED 1500 GALLON SEPTIC TANK 4 ROWS OF 5 HI CAPACITY T.O.F.=101.8± INFILTRATOR IM1530 GALLON PLASTIC TANK H-20 INFILTRAT( UNITS ' INV.=98.75 CONNECT TO NEW SEWER ESTABLISH VEGETATIVE COVER BACKFILL WITH CLEAN NATIVE OR +I j �§.I AT HOUSE, INV.=99.05± PERC SAND TO TOP OF CHAMBERS NOTES: BREAKOUT=TOP r' TOP ELEV.= 98 33 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV.=97 94 fI INVERTS, PRIOR TO INSTALLATION. S.A.S. 2) SEPTIC TANK & D-BOXSHALL BE SET LEVEL AND TRUE BOTTOM ELEV.=97.00 5' MINSEPARATION � LAYOUT TO .GRADE ON MECHANICALLY COMPACTED STABLE BASE . 2.83' 6" 6', GROUNDWATER OR SIX INCH CRUSHED STONE BASE, AS SPECIFIED INTO 4' (MIN.) OF NATURALLY EFFECTIVE WIDTH=12.8' 310 CMR 15.221(2). 3) INSTALL INLET .& OUTLET TEES AS REQUIRED. OCCURRING PERVIOUS SOILS SUITABLE SOILS 4 GAS BAFFLE TO BE INSTALLED ON OUTLET TEE ) NO G.W. EL=88.5 � 000000 000000. o AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL USE 4 ROWS OF 5 -HIGH CAPACITY H-20 INFILTRATOR UNITS o.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 WITH 6" SEPARATION BETWEEN EACH ROW & NO STONE SEPTIC SYSTEM 'PROFILE TYPICAL SECTION I-- 28"--1 I 2311 Olbsed End Plate Open End Plate N.T.S. SOIL LOG DESIGN CRITERIA w DATE: APRIL 28, 2022 NUMBEROFBEDROOMS 3 BEDROOMS SOIL EVALUATOR: PETER McENTEE PE, SE -1542 Z- - WITNESS: JAY GARDINER HEALTH AGENT SOIL TEXTURAL CLASS: CLASS ELEV. TP. DEPTH DESIGN PERCOLATION RATE <2 MIN/IN 100.0 0' .,.I 75" F--34 - A 1.25" DAILY FLOW: 330 GPD LOAMY SAND Side View End View DESIGN FLOW: 330 GPD 1CYR 4/z 99.2 10" B 'GARBAGE GRINDER: NO - NOT PERMITTED FOR GARBAGE G INDER - U R28 HIGH CAPACITY INFILTRATORS, H-20 LOADING LOAMY SAND p 11 PROPOSED SEPTIC TANK. 1500 GALLON CAPACITY 10YR 5/8 INFILTRATOR CHAMBERS LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF 96.2 46" - N:T.S. DISTRIBUTION BOX: 1 INLET, 4 OUTLETS (H.-20) C PROPOSED) SEPTIC SYSTEM UPGRADE PLAN USE 4 ROWS OF 5. HIGH CAPACITY INFILTRATOR H-20 UNITS WITH ED M -F SAND 2.5Y 6/6 N ST P 0 12.8' x 31.3 33 MAINq : AVENUE, " WEST: YARMOUTH, -' MA SIDEWALL AREA: NOT APPLICABLE - BOTTOM AREA: .(GENERAL USE APPROVAL FOR 4.73 SF/LF Prepared for: Cape d Septic Services, 350.Main St, W.Yarmouth, . MA 02673 Engineers: Surveyors: SCALE DRAWN .JOB. NO. (INFILTRATORS) 4 ROWS x 3.1.3 LF x 4.73 SF/LF = 59 .2 SF Engineering Works, In , JC Engineering, Inc. N.T.S. P.T.M. 188-22 DESIGN FLOW PROVIDED: 0.74 GPD SF 5922' SF = 43 / ( ) .3 GPD 88.5 138" 12 West Crossfield Rood Cranberry Hwy. PERC RATE 2 MIN/IN. ("B"&"C" HORIZONS) Forestdale, MA 02644 E.Waiaham, MA 02538 E.Wa DATE CHECKED SHEET NO. NOMINAL BED AREA: 12.8' x 31.3' = 400.6 SF (400 SF R Q'D) GROUNDWATER ENCOUNTERED AS NOTED (506) 477-5313 (508) 273-0377 5/3/22 P.T.M. 2 of 2