Loading...
HomeMy WebLinkAbout2021 Dec 21 J.M. O'Reilly & Associates, Inc. LETTER OF Engineering& Land Surveying Services 1573 Main Street,2nd Floor,P.O. Box 1773 TRANSMITTAL Brewster,MA 02631 (508)896-6601 Fax(508)896-6602 TO: DATE: JOB NUMBER: Town of Yarmouth 12/21/2021 6611 BW Board of Health 1146 Route 28 REGARDING: South Yarmouth, MA 02664-4492 Locus: 94 Iroquois Blvd, Yarmouth Shipping Method: Regular Mail ✓ Federal Express Certified Mail UPS Priority Mail Pick Up Express Mail n Hand Deliver COPIES DATE DESCRIPTION 1 12/02/21 Routine Operation and Maintenance Checklist for Perc-Rite Drip Dispersal system For review and comment: For approval: As Requested: For your use: 1 REMARKS: cc: John M. O'Reilly, P.E., P.L.S. Client Oakson, Inc. From: GJB If enclosures are not as noted,kindly notify us at once I' ROUTINE OPERATION AND MAINTENANCE CHECKLIST FOR PERC-RITE DRIP DISPERSAL SYSTEM Address: 94 lroquios Blvd, Yarmouth Date: 12/02/2021 Homeowner: Robert Warsheski Operator: Greg Brehm, WWTO Lic#:16149 Job #: 6611B-W HISTORICAL DATA and CURRENT READINGS Previous flow meter reading: 224,390 Design flow: 330 Date of last visit: 12/22/2020 Current flow meter reading: 247,585 Calculated water usage: 67.04 GPD Start-up dose rate Current dose rate ZONE 1: 2.1 GPM 2.6 GPM ZONE 2: ZONE 3: ZONE 4: FIELD CONDITIONS A. Drip dispersal field: visible wet spots YES NOD Comments: B. Air release valves: erosion YES❑ NOD leakage/spraying YES El NO❑✓ Comments: PUMP CHAMBER/FLOAT OPERATION A. Floats match pin lights in control panel YESD NO❑ Comments: B. Alarm float working YESD NO❑ Comments: C. Solids or scum present YES❑ NOD Comments: CONTROL PANEL A. Switches in AUTO position YESD NO❑ Comments: B. Peak Level light on YES❑ NOD Comments: C. Power and Run lights on (microprocessor) YES❑✓ NOD Comments: PUMP and VALVE OPERATION A. Pump in HAND position: flow meter running YES❑✓ NOD Comments: B. Zones 1-4 (one at a time): flow meter running YES D NOD dose rate correct YES❑ NO flush rate > dose rate YES❑✓ NOD Comments: C. Disc filter back flushing: working properly YES❑✓ NOD Comments: D. Disc filter inspection: excessive residue YES NOD cleaning required YESD NOD Comments: E. Switches returned to AUTO position YES D NO❑ Comments: F. RESET/CYCLE START: functioning properly YES D NO ❑ Comments: G. Hydraulic Unit: leaks, crimps, or other issues YES❑ NO D Comments: SEPTIC and/or PRE-TREATMENT TANKS A. Examine and clean effluent filter: excessive residue YES❑ NO D Comments: no effluent filter present B. Septic tank pumping recommended YES❑ NO D 1. Sludge depth:7" 2. Scum depth: 0 Comments: C. Service pre-treatment system YES❑ NOD Comments: N/A 2Operator signature / 5License No. 16149 Comments/Observations: Septic tank covers now at grade.