Loading...
HomeMy WebLinkAbout2021 Sep 7 J.M. O'Reilly & Associates, Inc. LETTER OF Engineering& Land Surveying Services 1573 Main Street,2nd Floor,P.O. Box 1773 ..1 ,NSMITTAL Brewster, MA 02631 rRi E@LIOYIED) (508) 896-6601 Fax(508) 896-6602 OCT 1 5 2021 HEALTH DEPT. TO: DATE: JOB NUMBER: Town of Yarmouth 10/08/2021 8402W Board of Health 1146 Route 28 REGARDING: South Yarmouth, MA 02664-4492 Locus: 41 Pheasant Cove Circle Yarmouthport, MA Shipping Method: Regular Mail ✓ Federal Express Certified Mail UPS Priority Mail Pick Up Express Mail Hand Deliver COPIES DATE DESCRIPTION 1 09/07/21 Routine Operation and Maintenance Checklist for Perc-Rite Drip Dispersal system For review and comment: For approval: As Requested: For your use: ,/ REMARKS: cc: John M. O'Reilly, P.E., P.L.S. Client Oakson, Inc. From: GJB If enclosures are not as noted,kindly notify us at once i . ROUTINE OPERATION AND MAINTENANCE CHECKLIST FOR PERC-RITE DRIP DISPERSAL SYSTEM Address: 41 Pheasant Cove Circle, Yarmouthport Date: 09/07/2021 Homeowner: Gerald McClellan Operator: Greg Brehm WWTO Lic#:16149 Job #: 8402W HISTORICAL DATA and CURRENT READINGS Previous flow meter reading: 136,482 Design flow: 330GPD Date of last visit: 12/21/20 Current flow meter reading: 171,706 Calculated water usage: 35,224gallons,134.96 GPD Start-up dose rate Current dose rate ZONE 1: 2.9 GPM 2.5 GPM ZONE 2: ZONE 3: ZONE 4: FIELD CONDITIONS A. Drip dispersal field: visible wet spots YES❑ NOD Comments: B. Air release valves: erosion YES ❑ NOD leakage/spraying YES❑ NO ✓❑ Comments: PUMP CHAMBER/FLOAT OPERATION A. Floats match pin lights in control panel YES❑✓ NOD Comments: B. Alarm float working YES❑✓ NOD Comments: C. Solids or scum present YESD NOD Comments: CONTROL PANEL A. Switches in AUTO position YES❑✓ NOD Comments: B. Peak Level light on YESD NOD Comments: C. Power and Run lights on (microprocessor) YESD NOD Comments: PUMP and VALVE OPERATION A. Pump in HAND position: flow meter running YESD NOD Comments: B. Zones 1-4 (one at a time): flow meter running YES D✓ NOD dose rate correct YES❑✓ NO❑ flush rate > dose rate YES D NOD Comments: C. Disc filter back flushing: working properly YES ID NOD Comments: D. Disc filter inspection: excessive residue YES❑✓ NOD cleaning required YES NOD Comments: E. Switches returned to AUTO position YES❑✓ NO❑ Comments: F. RESET/CYCLE START: functioning properly YES❑✓ NO ❑ Comments: G. Hydraulic Unit: leaks, crimps, or other issues YES NOD Comments: SEPTIC and/or PRE-TREATMENT TANKS A. Examine and clean effluent filter: excessive residue YESD NO❑ Comments: cleaned filter B. Septic tank pumping recommended YES❑ NO El 1. Sludge depth: 8" 2. Scum depth: 0 Comments: C. Service pre-treatment system YESD NOD Comments: N/A Operator signature License No. 16149 Comments/Observations: System is operating correctly mechanically. Replaced contactor in control panel,old one failed the day before this inspection.