HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot / 33 Zone of Contribution: In J�, Out_ Acreage,
TT/ r Commercial: ` Residential:
Street: /4/ 01#. C.�J, kr,c f
Village: Ric/
Floor Plan: ✓ #Bedrooms: 3
Owner: 1?5 e? L f i nl IN) Installer: �,eQ t�[, 1
/ c,a er-
Address: Phone:
Phone:
Builder: Engineer: ' 1\ ye r S 1 S O W S
Address: Phone: /
Phone:
N/A YES NO
1. Required#of copies received
2.Date of soils exam and percolation test not older than 2 years \ --
3.4-5 ft of naturally occurring pervious material,above water table ✓ ti
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: \-
6.Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation,deck Var.: \'
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab . Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
Vr
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: N
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj.water or bottom of test hole Var. v
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", '4"preferred v\ '
18. System meets breakout requirements PVC liner: Wall: \'
19. Specified tee sizes are proper,gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal \�
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox \ ,_, '
24. Manhole covers within 6"of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field -
26. Electrical permit for pump chamber/Separate meter for duplexes Z
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial: V
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater ..,
34.Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
k7
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 0 - 3'c 6 0101