HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot / 33 Zone of Contribution: In J�, Out_ Acreage, TT/ r Commercial: ` Residential: Street: /4/ 01#. C.�J, kr,c f Village: Ric/ Floor Plan: ✓ #Bedrooms: 3 Owner: 1?5 e? L f i nl IN) Installer: �,eQ t�[, 1 / c,a er- Address: Phone: Phone: Builder: Engineer: ' 1\ ye r S 1 S O W S Address: Phone: / Phone: N/A YES NO 1. Required#of copies received 2.Date of soils exam and percolation test not older than 2 years \ -- 3.4-5 ft of naturally occurring pervious material,above water table ✓ ti 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: \- 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation,deck Var.: \' 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab . Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: Vr 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: N 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj.water or bottom of test hole Var. v 15. System not in top or subsoil(A,B horizons)or 5' removal 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '4"preferred v\ ' 18. System meets breakout requirements PVC liner: Wall: \' 19. Specified tee sizes are proper,gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal \� 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox \ ,_, ' 24. Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field - 26. Electrical permit for pump chamber/Separate meter for duplexes Z 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: V 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater .., 34.Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd k7 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 0 - 3'c 6 0101