Loading...
HomeMy WebLinkAboutEngineer PlanTBM = EL. 1 1.4 BULKHEAD FOUND. 110.0 .LOT 460 AREA = 0-26 Acre PLAN BOOK 249 PAGE 3 ASSR MAP067 PCL I f Exist. 1 ,000 Gal 5ept c Tank rel -� o 2;.7' ➢ C 11.9 1 II 1 1 0 0 z o / N S` 'p0 — yVA1ER SE _ 1 J SHE 20.00 pRIVEW 713 11.8 11.6 0 10 00 4 FT. WIDE TRI REMOVAL (SEE ----- SOIL REMOVAL DETAIL FOR SOIL 15) LEGEND �— g[ PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE —W— EXISTING WATER SERVICE TEST PIT SCALE: 1" = 20' MAY 7'6 2022 HEALTH DEPT. 4 FT. WIDE TRENCHES FOR SOIL REMOVAL (SEE NOTE 15) EXISTING FAILED LEACHING W/IN FOOTPRINT OF PROP. LEACHING Yarmouth health Department Date SURVEY CONDUCTED BY: WELLER AND ASSOC. SEE PLAN ON FILE DATED: JULY 10, 2015 SOUTH YARMOUTH e�SSE Ro cPp�' LOCUS 14 CAPT. WRIGHT RD. 4 a P N� � Y 0 �^ ODES Rp. N �o LOCUS MAP LOCUS INFORMATION TITLE REF: 18437/322 PARCEL ID: MAP 067 PAR. 133 FLOOD ZONE: PROPERTY NOT IN FLOOD ZONE PROPERTY iS IN ZONE II SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 14 CAPT. WRIGHT ROAD SOUTH YARMOUTH, MA PREPARED FOR JOSEPH M. FINN MAY 25, 2022 OF I MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 ELEV. TOP NOTE: PLACE MAGNETIC MARKING TAPE. OVER ALL COVERS DROP NOTE: PLACE ALL COVERS TO WITHIN 6" OF FINISH GRAD BRING ALL C V F FINISH GRADE .END. INSTALL METAL RINGS/ SUR ACE IS PAVED. (Existing) FINISHED GRADE (11.5) = 12.40F.G.EI_: 11.80 � F.G.EL• 11.80 F.G. EL: 11.50 � MAINTAIN 29 MIN SLOPE OVER LEACHING AREA a INSPECTION PORT 'v F.G.EL: 1 .0 TO GRADE .� . 6" - � 6' INSPWnON Poor TO 807TOM OF STONE E WIN 3' OF BNISB CBME OUSE PERF PIP 10" TEE'S ARE BE 14" INV. 9.20 6 ®S= 1% (MIN.) 1 Y 4" SCH 40 PVC INV.= 8.90 INV. 9.32 INV. 9.03 EXIST. OUTLET INV. 9.57 GAS PROPOSED DB -5 BAFFLE 27.5' I ..... .. .. ..... V DISTRIBUTIOV BOX y (H2O) EXIST. 1,000 GALI. ON SEPTIC TANK 9" MIN COVER GAS BAFFLE TO B INSTALLED ON �0 �T d1AS f _. a cu ec o. 419 wSOL f]L1FR vAeRic �P� BREAKOUT EL. = 9.23 OUTLET TEE AS M NUFACTURED BY o y� TUF-TITE, ZABEL, DAREN M. / OR EQUAL n - 928101w NOTES: ME{YE INV. ELEV.=8.90 CONTRACTOR SHALL VERIFY ALL EXISTING o No. END ELEV.=8.76 PIPE INVERTS PRIOR TO CONSTRUCTION s/`. 3/4• - 1-1/z' 2) D -BOX SHALL BE SET LEVEL AND TRUE TO 'QfC/$jCov Daum, wasRE9 stage V25' X GRADE ON A MECHANICALLY COMPACTED SIX _ ITA \I` INCH CRUSHED STONE BASE, PECIFI D IN'- r 31CMR 15.221(2). 1 BOTTOM EL.= 8.2 I 3) REPLACE EXISTING 1,500 GALLON SEPTIC TANK / WITH 1,500 GALLON SEPTIC TANK IF FAILED, SEPARATION TO BOTTOM OF TH 6.76FT 5' ­L2.5' I 20' - I A DAMAGED OR UNDERSIZED. SEPTIC SYSTEM PROFILE TOP OF UNSUITABLE SOIL EL. 4.50 SEPARATION TO TOP OF UNS. SOIL 3.76' SOIL ABSORPTION SYSTEM (SECTION) 4) INSTALL INLET & OUTLET TEES W/� cns BAFFLE As REQUIRED ADJUSTED GROUNDWATER EL. 1.50 GENERAL NOTES: DESIGN CRITERIA 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL SOIL LOGS BOARD OF HEALTH AND THE DESIGN ENGINEER. NUMBER OF BEDROOMS: 3 BED OOM DESIGN 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE DATE: - MAY 20, 2015 SOIL EVALUATOR: REN R.S., CSE SOIL TEXTURAL CLASS: LASS 2 0.60 GPD SF ( / ) LOCAL RULES AND REGULATIONS #1614 DESIGN PERCOLATION RATE: <2 MIN I 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR WITNESS: AMY VONHONE, YARMOUTH HEALTH DAILY FLOW: 110 G.P.D. X 3 BR = 330 G.P.D. TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. TP- 1 �. GARBAGE GRINDER: NO (not designed for garbage grinder) 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN Elev. Depth 11.50 0" SEPTIC TANK: 330 gpdx 200% = 660 gpd, RE -USE EXIST. 1,000G SEPTIC TANK ENGINEER BEFORE CONSTRUCTION CONTINUES. A LOAMY SAND 10YR 4/1 LEACHING AREA REQUIRED: (330)/0.60 = 550 S.F. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 10.83 9" 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF B THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF LOAMY SAND 10YR 6 / 4 HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 9.00 30" USE 27.51 X 20' W LEACHING FIELD WITH 3 LATERALS 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. C MEDIUM- SAND �(-o' .6Y 6/4 V/" 4'S 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE C2 LOAMY -FINE- 84" BOTTOM AREA: 27.5 x 20 = 550 SF THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. SAND TOTAL SQUARE FEET PROVIDED = 550 vs. 550 REQ'D 10. EXISTING LEACHING (WITHIN PROP. FOOT PRINT) TO BE PUMPED, CRUSHED 10YR 6/6- 2.50 108" DESIGN FLOW PROVIDED: 0.6(550 S.F.) = 330 G.P.D. vs 330 G.P.D. Teq'd AND REMOVED PER TITLE 5. REPLACE W/ CLEAN MEDIUM. SAND. C3 MEDIUM - SAND PROPOSED SEPTIC SYSTEM UPGRADE PLAN 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 2.5Y 6/6 1.50 120" 12. THIS PLAN 1S TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. PERC RATE <2 MIN/IN. ("C" HORIZON) 14 CAPTAIN WRIGHT ROAD SOUTH YARMOUTH, MA q NO GROUNDWATER OBSERVED,! , Prepared for: Finn ` 14. ALL PIPING TO BE 4` SCH 40 0 1/8'/FT (UNLESS SPECIFIED)t F=---� -- 15. INSTALLER TO CONDUCT TWO 4' WIDE TRENCHES ACCROSS PROPOSED LEACH FIE�� (AS SHOWN) Design and Site Plan by: SCALE DRAWN DATE TO EL. 2.50 TO REMOVE UNSUITABLE "C2' SOIL LAYER AND REPLACE WITH CL MED. SAND. MEYER & SONS, INC. N.T.S. DMM 05/25/22 PO BOX 981 • I, Damen M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 REV DATE: SHEET NO. to conduct soil evaluations and that the above analysis has been performed by me consistent with the EAST SANDWICH, MA 02537 requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. 506-362-2922 2 Of 2