Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH '�Z /I7 i �! ._� SEWAGE PLAN REVIEW CHECKLIST Location: A.M. -16 Lot Zone of Contribution: In`7' Out Acreage 2 t) • L Comm- .1: Residential: d Street: / /`'7l e' C k Village: G�%� Lr0lli Floor Plan. #Bedrooms: Owner: yc�' t re./7' Installer: ( ate 4i)* 2 ` 5 Address: Phone: 775-- .-!7 Phone: Builder: Engineer: G i- ntii-o--- Address: Phone: 2 Z. Phone: - - g < Zuzl// r)/'` / N/A YES NO J 1.Required#of copies received '✓ 2. Date of soils exam and percolation test not older than 2 years `--- _- 3. 4-5 ft of naturally occurring pervious material, above water table l% 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L...----- 5. Water line 10 ft from septic components Var.: ✓ 6. Benchmark indicated and shown-NGVD if near wetlands (..------- 7. Septic tank minimum 10 ft from foundation,deck Var.: Evi 5/-G/ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: ✓' 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: �/ 11. Tank/leaching minimum 10 ft from property line Var.: --.---- 12. System meets all other setback requirements Var.: .------ 13. Uses adjustment for maximum high groundwater Var.: ----- 14. /14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: i_� 15. System not in top or subsoil(A,B horizons)or 5'removal t� 16.Proposed contours are suitable L-•''' 17. System meets slope requirements-min. 1/8", 'A"preferred l/ 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee c/ 20. Sewage is under 10,000 gpd for parcel 21. No garbage disposal V 22. System adequately sized for its intended use ✓ 23. Minimum 6"stone or compacted below tank and dbox ......---- 24. 24.Manhole covers within 6"of grade,pump chamber cover to grade L.----- 25. /25. Inspection port on plastic chambers/leach field 1.----- 26. Electrical permit for pump chamber/Separate meter for duplexes 1.----- 27. .127. Pump system-2" line,weep hole,check valve,tee in dbox,pump size 1.----' 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet, under driveway/parking 4.--- 30. Buoyancy calculations for tank/pump chamber i11 31. Engineer to inspect and certify soils: wall: commercial: j----- 32. -f32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,i/- 33. H-20 loading is subject to vehicular traffic, groundwater i 34. Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house if 36. Deed Restriction required max. #bedrooms: max. flow: gp� 37. Check area lots for groundwater/Label groundwater in Assessor's Map ! /-- Plan reviewed by: 6/03/03