Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lofe9.013 Zone of Contribution: In Out Acreage Commercial: Residential: Street: 1/1/4..irle p eit,ci'N c .e. Village: Floor Plan: #Bedrooms: Owner: R`//,� f/v a c{ Installer: D /• 7 Co sir& c!i'(}c� Address: Phone: Phone: Builder: Engineer: & - , li a 4 .,'- Address: Phone: Phone: N/A YES NO 1.Required#of copies received / 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table ti✓ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5. Water line 10 ft from septic components Var.: 14,- 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: ✓ 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: .10 #-Ila f• ;0 u' V.-- • 9. Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: f 11.Tank/leaching minimum 10 ft from property line Var.: l - 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.`. --,-� 15. System not in top or subsoil(A,B horizons)or 5' removal / 16.Proposed contours are suitable �--� 17. System meets slope requirements-min. 1/8", '4"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper,gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel %./y- 21.No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox ‘✓ 24.Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes l 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber v.' 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature f 33.H-20 loading is subject to vehicular traffic,groundwater ,/" 34.Title V Application and permit fee,installer signature r� 35. Foundation footing min. 2 feet above adjusted ground water for new house L7../ 36.Deed Restriction required max. #bedrooms: max. flow: gpd [7- 37. Check area lots for groundwater/Label groundwater in Assessor's Map N PIan reviewed by:_ � 6 03 01