HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 3+ Lot ivS---
Zone of Contribution: In Out V Acreage 415bt SF
Commercial: Residential: 17-
Street:
/Street: ✓ . D Axl IS c S--i-
Village:
Village: �ro-4.77--#F Floor Plan: ✓ #Bedrooms: ..
Owner: F " i 'O Installer: --e 5 d,C-O S
Address: Phone:
Phone:
Builder: Engineer: 4.1*5eiJ
Address: Phone:
Phone:
N/A YES7 NO
1. Required#of copies received ./ V
2. Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓
5.Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands 1.7
7. Septic tank minimum 10 ft from foundation, deck Var.: _ /
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 2.N" C.4-as..,L.
9.Leaching minimum 100 ft from wetlands Var.: ✓
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11.Tank/leaching minimum 10 ft from property line Var.: <' S5 ✓
12. System meets all other setback requirements Var.: /
13.Uses adjustment for maximum high groundwater Var.: 1 ` .i
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓
15. System not in top or subsoil(A,B horizons)or 5' removal V,
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", %"preferred ✓_r
18. System meets breakout requirements PVC liner: Wall: ✓/
19. Specified tee sizes areproper,gas baffle on outlet tee ✓
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal /
22. System adequately sized for its intended use 141X - rb sits ✓
23.Minimum 6"stone or compacted below tank and dbox / ,
24. Manhole covers within 6"of grade,pump chamber cover to grade •
25. Inspection port on plastic chambers/leach field I/ ✓
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size - ./
28. Septic tank/pump chamber to be factory waterproofed ✓
29.Vent provided if leaching below 3 feet,under driveway/parking ✓/
30.Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial: //
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature J
33.H-20 loading is subject to vehicular traffic,groundwater ✓ /
34.Title V Application and permit fee, installer signature ✓
35.Foundation footing min.2 feet above adjusted ground water for new house ✓
36. Deed Restriction required max. #bedrooms: max. flow: gpd 1/
37. Check area lots for groundwater/Labelat� � groundwater in Assessor's Map
Plan reviewed by:_ �a `'`t _6-(11(2e2__ _ 60303