Loading...
Review Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. -7-7 Lot 44S Zone of Contribution: In✓Out_ Acreage 6, (o 46 1: S F Commercial: Residential: t/ Street: t t1 4e(._L.1 s 'fit--t u€ Village: Scro --i.{ Floor Plan: V #Bedrooms: 3 Owner: 111-4 L4 T3 L ! cgs...3 Installer: Address: Phone: Phone: Builder: Engineer: A-4-4- C Address: Phone: Phone: N/A YES NO 1.Required#of copies received ✓ 2.Date of soils exam and percolation test not older than 2 years V 3.4-5 ft of naturally occurring pervious material,above water table V 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5.Water line 10 ft from septic components Var.: I / 6.Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation, deck Var.: / 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ,�, 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 16- 13.Uses adjustment for maximum high groundwater Var.: V/ 14. Leaching set 0 above adj. water or bottom . -st hole Var.. ✓ 15. System not in top or subsoil(A,B horizons) .0 oval V 16.Proposed contours are suitable ✓ 17. System meets slope requirements-min. 1/8", '4"preferred V 18. System meets breakout requirements PVC liner: Wall: f ✓ 19. Specified tee sizes are proper, gas baffle on outlet tee ✓ 20. Sewage is under 10,000 gpd for parcel ✓ 21.No garbage disposal ✓ 22. System adequately sized for its intended use ✓ _ 23.Minimum 6"stone or compacted below tank and dbox ✓ 24. Manhole covers within 6"of grade,pump chamber cover to grade / 25. Inspection port on plastic chambers/leach field V 26.Electrical permit for pump chamber/Separate meter for duplexes / 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓ 28. Septic tank/pump chamber to be factory waterproofed ./ 29.Vent provided if leaching below 3 feet,under driveway/parking _ V 30.Buoyancy calculations for tank/pump chamber / 31.Engineer to inspect and certify soils: wall: commercial: / 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V 33.1-1-20 loading is subject to vehicular traffic, groundwater V 34.Title V Application and permit fee, installer signature / 35.Foundation footing min. 2 feet above adjusted ground water for new house �/ ‘,/ 36.Deed Restriction required max. #bedrooms: max. flow: gpd ,� 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by. �'44,1-/ 6 03 03