HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
, SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot A/4 2- Zone of Contribution: In_ Out Acreage
• / Commercial: Residential:
Street: / 76-, �7A'' / /ai_
Village: / Floor Plan: l #Bedrkoms:
Owner: Keil 4-e-ate---* Installer: ,
Address: Phone:
Phone:
Builder: • Engineer: y ,�' �j1�
Address: Phone: ��L 4
C
Phone: 7 '
bta 1010-0--' 4vwy/Q/
N/A YES NO
1.Required#of copies received lr .
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table i
4.Foundation 2 ft above high point of road H.P.: i, c Fnd: (JU 11Jar.: 1,c
5. Water line 10 ft from septic components Var.: (...------i
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: (�
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L....----
9. Leaching minimum 100 ft from wetlands Var.: �...----
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: \..._.---
11. Tank/leaching minimum 10 ft from property line Var.: ----
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj.water or botto o test h31e Var.: ...../.
_�1615. System not in top or subsoil(A,B horizons) 5' remova L.------
16.
.Proposedcontours are suitable t
17. System meets slope requirements-min. 1/8", '/4"preferred L.--/'
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper,gas baffle on outlet tee '1/4.-----
20. Sewage is under 10,000 gpd for parcel l/
21.No garbage disposal .....-----
22. System adequately sized for its intended use �_--
23.Minimum 6"stone or compacted below tank and dbox ,_.-----
24.
_.----'24.Manhole covers within 6"of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field C
5
26.Electrical permit for pump chamber/Separate meter for duplexes L.----
27.
f27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size
28. Septic tank/pump chamber to be factory waterproofed %......-----
29.
/29.Vent provided if leaching below 3 feet,under driveway/parking ../
30. Buoyancy calculations for tank/pump chamber .----"
31. Engineer to inspect and certify soils: wall: commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ._-/-
33.
_/33.H-20 loading is subject to vehicular traffic, groundwater
34. Title V Application and permit fee, installer signature ._. -
35.Foundation footing min. 2 feet above adjusted ground water for new house L------
36.
/36. Deed Restriction required max. It bedrooms: max. flow: gpd •
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by:
a.-
6/03/03