HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. - i Lot WI Zone of Contribution: In Out Ci Acreage
,, Commercial: Residential: -
Street: iq VVtt� kQ
Village: Floor Plan: ties # Bedrooms: l
Owner: A d/till bed/1 l04LO-- Installer: $ E c4 Vitfi:
,14
Address: Phone:
Phone:
Builder: Engineer: WI VC '1,4,111.441
Address: Phone:
Phone:
77/f
N/A YES , NO
1.Required# of copies received V
2. Date of soils exam and percolation test not older than 2 years V
3. 4-5 ft of naturally occurring pervious material, above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 7-
5. Water line 10 ft from septic components Var.: V' -
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: ✓
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: ✓
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t/
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons) or 5' removal i<:,
16.Proposed contours are suitable !/
17. System meets slope requirements-min. 1/8", '/"preferred
18. System meets breakout requirements PVC liner: Wall: i/
19. Specified tee sizes are proper, gas baffle on outlet tee ✓
:. 20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal f
22. System adequately sized for its intended use 1
23.Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6" of grade,pump chamber cover to grade l,/'
25. Inspection port on plastic chambers/leach field V
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve, tee in dbox, pump size V
28. Septic tank/pump chamber to be factory waterproofed 7
29. Vent provided if leaching below 3 feet, under driveway/parking
,ai :uoyancy calculations for tank/ ump chamber
b< ngineer to inspect and certify (i it It soils: wall: commercial: ,/
a, ngineer/Registered Sanitarian and Land Surveyor stamps/signature Ih tSS rlj L� YID/i f. f?/ay X
3. H-20 loading is subject to vehicular traffic, groundwater
. 34. Title V Application and permit fee, installer signature i
35. Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in AsseiA......ssor's Map ✓
Plan reviewed by: �, &03/o3