Loading...
HomeMy WebLinkAboutEngineer PlanN /F HARVEY SAFE PRIOR TO CONSTRUCTION --UTILITY LOCATIONS SHOWN INCOMPL M 6 a ri n_ Y 0 0 m 30.32 J a `� 31.0` N /F 2.1 - NAYER 2.0 i 32.3 f� i 32. 22 -:a31 QP�G .Il QQ' rn t 1 2�2' I ; 32.5 32.8 32,6 L325 rd 33,2 �`� J BENCH MARK--S.E. CORNER OF CONC. PAD = 32.63 ASSIGNED N /F SOARES 30. ,0/YO :. �( A9 OCA 4y- a BENCH MARK -TOP MAG. NAIL SET IN PAVEMENT= 30.00 ASSIGNED 2 Ldp x 3tk F 32.0. A ?9 -. F � 5 � � 31,'2. LOT 11 11,113±S.F. 31,x. Z . 31.2 N/F PRIZZI 33.90± Foundation Y20-14 NOTES Contella.dwg _ 1. LOCUS 1S A.M. 22, PARCEL 132. Folder 5614/74 2. ELEVATIONS SHOWN ARE ASSIGNED. 3. LOCUS IS IN FLOOD ZONE X(OUTSIDE 0.2% RISK) ON FIRM DATED JULY 16, 2014. 4. ALL PIPES TO BE 4 SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 1COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. 7.INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. COVERS: BUILD UP COVERS TO 6" BELOW GRADE --1 ON D -BOX, 2 ON LEACHING 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). 13. PUMP AND FILL ANY EXISTING CESSPOOL/LEACHPIT. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT. 14. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. TEST HOLE DATE: September 3, 2020 PERFORMED BY- Ron Cadillac, Soil Evaluator NO GRADE CHANGES WITNESSED BY: Mallory Langler, RS ARE PROPOSED PERC RATE: t2'-00"/inch (B layer) SOIL SURVEY(1993): Carver coarse sand GEOLOGIC MAP(1986): Harwich outwash plain deposits 12 ADS ARC 36HC Invert 30.20 Invert 30.69 / CHAMBERS NOT TO SCALE LOCATION MAP TEST HOLE 1 DEPTH (inches) ELEV.(feei 0 31.4 A layer tOyr 4/3 loamy sand 6" 30:9 B layer 10yr 6/8 `m loamy sand 24 29.4 C1 layer 10yr 6/7 loamy medium fine sand End Exist. C.I. Pipe Proposed H-10 Use Gas Baffle Top Units=29.93 S=1"/ft 9" min. cover Invert 29.50 0 Filter Cloth / Proposed S=1 /2"/ft Proposed - t r'�. 3" Max. d 1500 Gal. r - Inspection Port Invert 30.45 T _A t Septic Tank __---__ no water Proposed Invert 29.67 - Proposed _ 10.75" 132" t ✓ 2&600 6" Stone or compact Invert 29.508 2' Bottom Level ` 29.24 t 1 Proposed Propos i t 30.0 3 -1 j- 14 --j -01 Bottom TH1=20.4 31.82 t I I t t t I - DESIGN DATA `° LEACH AREA BEDROOMS: 3 USE 12 ADS ARC 36HC CHAMBERS IN GARBAGE GRINDER: __ No - -- ---TWO- TIZENC-HES; -EACH 30' -fit -34:5". X REQUIRED CAPACITY: 330 GPD 10.75" DEEP, AS SHOWN. PROPOSED SEPTIC TANK: 1500 GAL. EFFECTIVE LEACHING AREA: 467.4 SF 7.79 ITS X X .95UNIT=38.95 7 4 UNIT -- 12 UNITS X 38.95 SF/UNIT-4574 LVRM HBDRMBDRM DESIGN CAPACITY: 345 GPD [(467.4 SF) X .74 GPD/SF] GAR KIT. rBATHTBDRM , FAMRPit , x 3 DURING COVIDI9 CALL 3a2s RJ. CADILLAC FOR INSPECTION BENCH MARK --TOP CENTER OF CONC. BOUND = 32.25 ASSIGNED TH 1 LEGEND TEST HOLE LOCATION, NUMBER -W- WATER LINE MARKINGS -E- OVERHEAD ELECTRIC WIRES (IF SHOWN) --- - GAS LINE MARKINGS x87 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) -6 EXISTING CONTOUR _._-s--- PROPOSED CONTOUR y UTILITY POLE (IF SHOWN) EXISTING DRAINAGE CATCH BASIN - - FENCE (IF SHOWN, NOT ALL SHOWN) TREE (IF SHOWN, NOT ALL SHOWN) THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED STAMP AND SIGNATURE. HEALTH AGENT APPROVAL DATE ya month Health D P ''anent EXISTING FLOOR PLAN NOT TO SCALE SITE PLAN FOR CANTELLA PROPERTY REE(�[Rovv LID SEP 2 8 2020 HEALTH DEPT. LOT 11, 7 CUTTER LANE, W. YARMOUTH, MA SEPTEMBER 24, 2020 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 02020 BY R.J. CADILLAC(508) 775-9700 PAGE 1 OF 1