Loading...
HomeMy WebLinkAboutEngineer PlanLEGEND N EXISTINGSEPTIC TANK v 101 ---- EXISTING CONTOUR TOP OF TANK, EL.=95.72 ry d INV. (OUT), EL.=94.39± a x 100.95 EXISTING SPOT GRADE R r Rood EXISTING LEACH PIT CS/ V—tiGW-- UNDERGROUND WIRES yeF �gF� W°sfc PUMP AND FILL WITH SAND I 95 32 m — G EXISTING GAS SERVICE —W— EXISTING WATER SERVICE Min er sf°� Benchmark Set - 5 24 i 0 � TEST PIT � LOCUS a ORANGE PAINT MARK A, °ti ONLANDSCAA si IE 8,400'00 ' � ��a $ BENCHMARK ROUTE 6 EL.e fence a?4' N 06 stocko.. ° 9 - 3 95. `0 LOCUS MAP -9 �ov 5 N 60°20'00" E 95k+ c' PRO S•. S3 + NOT TO SCALE J 13.51 CB/dh swwG 0 q 94 72 y ReaM Department 1t3.51' `r 4.78 �DE� 94.35 ` N `r' '" 9 5 GENERAL NOTES: +• . ^. � 95,59 �y X 95,94 �1 '94 23 � L � 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL , \ ,e BOARD OF HEALTH. AND THE DESIGN ENGINEER. 1�� X •96,09 >- X de fence. Qom. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS 9,4,84 �" �-._ u, c \ OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE O I=A. 5{0 95 41 as; sem,\ LOCAL RULES AND REGULATIONS.. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR deck ., \\N TO INSPECTIONS AND APPROVAL BY THE BOARD OF HEALTH AND THE / d a 9", 606 .DESIGN ENGINEER. cn ..% 96.58 above a 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING NT'�.\ paved FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN she boo UT 134''jE,//� �� �' driveway f ENGINEER BEFORE CONSTRUCTION CONTINUES. 96,51 wp't'// / /m l 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. r Retl Wall y:. 'J�i'�X/STING/`,%z �5 6,5A'6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF J To EL. =varies HOUSE (#87)�A THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF B tt. EL.= 6..4i HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. //`. TOF 1 o3. at , / CELLAR FL. EL.=96.3i/ ' WOI� i� �. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE... 8. THERE ARE. NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. rf r r ck de {e c i 1 / 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS i 10204 �' AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE X 8,40 �, ' DIRECTED BY THE APPROVING AUTHORITIES. I -.-� Reit. Wall �- 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY i r+ x 10(',47. ; IS 7f.8 Top EL. =100.6± i THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING Botta EL. varies CONSTRUCTION. _ 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 11 �� w4�� lOQ..6'" r 1N THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND 16, t768i' S.F. ' REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 LMR 255(3). 6 068 S 1F �. 6 101 02 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE ' 9 /Y' f / Lamp INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL. 't �r ✓ Parcel 64. 0`1' 92 00,00 13. THIS PLAN IS TO BE USED FOR SEPTIC. SYSTEM PURPOSES ONLY AND /- V ')`L.. 99,75 IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. 4' aced P aVed OF ), AND; '• ;r c ,_� "`- f � 1"190 arg100,50 ln9 PLAN REFERENCE: LAND COURT PLAN 36472 B -SHEET 2 LOT 14 P �� Mgss CERTIFIED PLOT PIAN BY C.R. SHORT, DATED 6/21/83 �� - ---- Rlv 9PROPOSED SEPTIC SYSTEM UPGRADE PLAN men± O o .PETER L �, `- g McENTEE 87 HELMSMAN DRIVE YARMOUTHPORT MA yBrant 99,67 e cf P N CIVIL > > 924 _ -- edge �CNo. 35109 Prepared for: Nadine Donovan, 87 Helmsman Dr, Yarmouthport, MA 02675 9 J 8.89 REGI$fER�� �Q Engineering by: SCALE DRAWN JOB. NO. B.os e, 1 NES FSS Engineering Works, Inc. 1 "=20' P.T.M. 155-09 51- (69 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. i) (508) 477-5313 5/30/09 P.T.M. 1 of 2 SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & T.O.F. OUTLET AND SET TO 6" OF FINISH GRADE - EXISTING � F.G. EL.=97.0t 48" LIQUID LEVEL GAS BAFFLE • 'P L = 10' O S=1% (MIN.) 4"SCH40 PVC INV.=93.77 NOTES: 1) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 2) INSTALL INLET & OUTLET TEES AS REQUIRED. 3) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. 4) MAXIMUM COVER OVER SEPTIC TANK, D -BOX & S.A.S. SHALL BE 36". DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO EXISTING SEPTIC TANK: 1000 GALLON CAPACITY LEACHING AREA REQUIRED: (330) = 445.9 S.F. .74 USE 2-500 GALLON LEACHING CHAMBERS IN SERIES SIDEWALL AREA: 2(13.2' + 23.0') X 2 = 144.8 S.F. BOTTOM AREA: 13.2' x 23.0' = 303.6 S.F. TOTAL AREA: ..... ............ .............. _ ... ............ 448.4 S.F. DESIGN FLOW PROVIDED: 0.74(448.4) = 331.8 G.P.D. NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:92.5 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. POSED D -BOX PROPOSED S.A.S. ALL RISER & COVER INSTALL RISER & COVER OVER ONE CHAMBER AND TO 6" OF GRADE SET TO 3' OF F.G. TO SERVE AS INSPECTION PORT � F.G. EL: 95.81 F.G. EL: 95.8t(MAX.) L=8' ® S=1% (MIN.) 2" LAYER OF 1/8" TO 1/2" 4"SCH40 PVC DOUBLE WASHED STONE 91-mo ep BB (0 , ,V,�I t P III E� l alts tl`aaaaaaa No -3/4" TO 1-1/2" DOUBLE 4' 5.2' 4' WASHED STONE NV.=93.60 � EFFECTIVE WIDTH = 13.2' INV.=92.00 2-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN TOP CONC. ELEV.=92.8 BREAKOUT ELEV.=92.5 INV. ELEV.=92.00 BBaa ease MEM aaaaa aaeaa ease eases BOTTOM ELEV.=90.00 3 I 2 X 8.5'=17.0" 5' MIN. ABOVE BOTTOM OF EFFECTIVE LENGTH = 23.0' T.P. EXCAVATION OR G.W. LEACHING SYSTEM SECTION GROUNDWATER, EL.=85.0 SYSTEM PROFILE N.T.S. SOIL LOG DATE: MAY 21, 2009 SOIL EVALUATOR: PETER MCENTEE PE WITNESS: PHILLIP RENAUD HEALTH AGENT ELEv. TP -1 DEPTH 95.5 o" 94.8 A SANDY LOAM 0YR 4/2 all B 4" KNOCKOUT SANDY LOAM 20" DIA. COVER t OYR 5/8 92.5 36" C1 PERC M -C SAND 2.5Y 6/4 85.0 1 126" PERC RATE <2 MIN/IN. ("C" HORIZON) NO GROUNDWATER ENCOUNTERED (3) 5" DIA.OUTLETS 15.5" r 16 F2„ 4' 1 15.5" 12„ ` " 61-„ L: 8„ P H-10 LOADING 2 D -BOX N.T.S. 1�1 �1 I 111 t I �1 til 1�1 1� 1�1 til � � t� 1�1J�11�11� t�lt�ll f1�1t It�l 1�11�f 1_�1 t.f1�1t�11�11�1t� t 102" 500 GALLON CAPACITY, H-10 LOADING N.T.S. 62" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 87 HELMSMAN DRIVE, YARMOUTHPORT, MA Prepared for: Nadine Donovan, 87 Helmsman Dr, Yarmouthport, MA 02675 Engineering by: SCALE DRAWN JOB, NO. Engineering Works, Inc. NTS P.T.M. 155-09 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 5/30/09 P.T.M. 2 of 2 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT O 4" KNOCKOUT 4" KNOCKOUT 500 GALLON CAPACITY, H-10 LOADING N.T.S. 62" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 87 HELMSMAN DRIVE, YARMOUTHPORT, MA Prepared for: Nadine Donovan, 87 Helmsman Dr, Yarmouthport, MA 02675 Engineering by: SCALE DRAWN JOB, NO. Engineering Works, Inc. NTS P.T.M. 155-09 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 5/30/09 P.T.M. 2 of 2