Loading...
HomeMy WebLinkAboutRestroom Q15315 RF Truss DESIGN DRAWINGS 040420224.512 =4x10 =4x4 =1.5x4 =3x4 =4x6 =3x6 =3x4 =1.5x4 =4x4 =4x10 91 12 11 10 2 8 73 4 62221 5 T1 T1 B1 B2 W2 W1 W2 W1 HW1 HW1 1-4-8 24-10-8 1-4-8 -1-4-8 5-8-12 17-5-12 5-8-12 11-9-0 6-0-4 23-6-0 6-0-4 6-0-4 6-10-6 15-2-3 8-3-13 23-6-0 8-3-13 8-3-135-2-130-9-95-2-7Scale = 1:46.7 Plate Offsets (X, Y): [2:0-5-13,Edge], [8:0-5-13,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)30.0 Plate Grip DOL 1.15 TC 0.77 Vert(LL)-0.16 10-12 >999 360 MT20 197/144 Snow (Pf)30.0 Lumber DOL 1.15 BC 0.70 Vert(CT)-0.24 10-12 >999 240 TCDL 5.0 Rep Stress Incr YES WB 0.14 Horz(CT)0.06 8 n/a n/a BCLL 5.0*Code IBC2015/TPI2014 Matrix-MSH BCDL 10.0 Weight: 89 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x6 SPF 1650F 1.5E --2-6-0, Right 2x6 SPF 1650F 1.5E --2-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 2-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-8-11 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)2=1154/0-5-8, (min. 0-2-0), 8=1154/0-5-8, (min. 0-2-0) Max Horiz 2=214 (LC 16) Max Uplift 2=-505 (LC 19), 8=-505 (LC 15) Max Grav 2=1263 (LC 28), 8=1263 (LC 32) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-639/30, 3-4=-2073/851, 4-21=-1868/750, 5-21=-1813/762, 5-22=-1813/762, 6-22=-1868/750, 6-7=-2073/851, 7-8=-583/29BOT CHORD 2-12=-760/1940, 11-12=-409/1328, 10-11=-409/1328, 8-10=-682/1853 WEBS 5-10=-227/568, 6-10=-447/368, 5-12=-226/568, 4-12=-447/367 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=142mph (3-second gust) Vasd=112mph; TCDL=3.0psf; BCDL=6.0psf; h=16ft; B=26ft; L=26ft; eave=4ft; Cat. II; Exp C; Open; MWFRS (directional) and C-C Corner (3) -1-4-8 to 1-7-8, Exterior (2) 1-7-8 to 11-9-0, Corner (3) 11-9-0 to 14-9-0, Exterior (2) 14-9-0 to 24-10-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=30.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=30.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.20 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 30.0 psf on overhangs non-concurrent with other live loads. 6)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf (or less) is not adequate for a shingle roof. Architect to verify adequacy of top chord dead load.7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 505 lb uplift at joint 2 and 505 lb uplift at joint 8. 10)This truss is designed in accordance with the 2015 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply Cape Cod Inflatable Park -Restroom Q15315 A01 11Common Job Reference (optional) Stark Truss Company, Inc., North Kingstown, RI 02852 Run: 8.53 S Jan 25 2022 Print: 8.530 S Jan 25 2022 MiTek Industries, Inc. Mon Apr 04 15:22:47 Page: 1 ID:PIHXtJL_QzUBmSLoDjqHNqzU4Zo-a0joKIHGUIWWQFl1yXggzrIkaEnBnvApyz5498zU3xs 4.512 =4x8 =4x4 =3x4 =3x4 =3x8 =4x8 =3x8 =4x6 =3x4 =3x4 =4x4 =4x8 151 25 24 23 22 21 2019 18 17 16 2 14 2927 133 124 26 28 5 113839106 97 8 T1 T1 B1 B2 W2 W1 W2 W1 ST6 ST4 ST5 ST3 ST2 ST1 ST4 ST5 ST3 ST2 ST1HW1 HW1 1-4-8 24-10-8 1-4-8 -1-4-8 5-8-12 17-5-12 5-8-12 11-9-0 6-0-4 23-6-0 6-0-4 6-0-4 6-10-6 15-2-3 8-3-13 23-6-0 8-3-13 8-3-135-2-130-9-95-2-7Scale = 1:46.9 Plate Offsets (X, Y): [2:0-4-13,0-0-3], [14:0-4-13,0-0-3], [19:0-3-0,0-1-4] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)30.0 Plate Grip DOL 1.15 TC 0.39 Vert(LL)-0.11 22 >999 360 MT20 197/144 Snow (Pf)30.0 Lumber DOL 1.15 BC 0.63 Vert(CT)-0.17 22 >999 240 TCDL 5.0 Rep Stress Incr YES WB 0.24 Horz(CT)0.05 14 n/a n/a BCLL 5.0*Code IBC2015/TPI2014 Matrix-MSH BCDL 10.0 Weight: 117 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x6 SPF 1650F 1.5E --2-6-0, Right 2x6 SPF 1650F 1.5E --2-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 3-9-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-11-8 oc bracing. JOINTS 1 Brace at Jt(s): 26, 28 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)2=1154/0-5-8, (min. 0-2-0), 14=1154/0-5-8, (min. 0-2-0) Max Horiz 2=-213 (LC 12) Max Uplift 2=-504 (LC 19), 14=-506 (LC 15) Max Grav 2=1262 (LC 28), 14=1264 (LC 44) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-554/198, 3-4=-2035/791, 4-5=-1994/815, 5-38=-1859/767, 6-38=-1841/770, 6-7=-1880/809, 7-8=-1883/849, 8-9=-1869/843, 9-10=-1879/808, 10-39=-1840/770, 11-39=-1859/767, 11-12=-1994/815, 12-13=-2035/791, 13-14=-487/195 BOT CHORD 2-25=-711/1891, 24-25=-711/1891, 23-24=-711/1889, 22-23=-401/1339, 21-22=-401/1339, 20-21=-402/1342, 19-20=-402/1342, 18-19=-402/1342, 17-18=-639/1808, 16-17=-637/1808, 14-16=-637/1808 WEBS 8-28=-330/618, 18-28=-323/612, 18-29=-408/283, 11-29=-275/199, 23-26=-320/613, 8-26=-344/650, 5-27=-275/199, 23-27=-410/285 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=142mph (3-second gust) Vasd=112mph; TCDL=3.0psf; BCDL=6.0psf; h=16ft; B=26ft; L=26ft; eave=4ft; Cat. II; Exp C; Open; MWFRS (directional) and C-C Corner (3) -1-4-8 to 1-7-8, Exterior (2) 1-7-8 to 11-8-2, Corner (3) 11-8-2 to 14-8-2, Exterior (2) 14-8-2 to 24-10-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=30.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=30.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.20 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 30.0 psf on overhangs non-concurrent with other live loads. 7)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf (or less) is not adequate for a shingle roof. Architect to verify adequacy of top chord dead load.8)All plates are 1.5x4 MT20 unless otherwise indicated. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 504 lb uplift at joint 2 and 506 lb uplift at joint 14. 13)This truss is designed in accordance with the 2015 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply Cape Cod Inflatable Park -Restroom Q15315 A01GE 11Common Structural Gable Job Reference (optional) Stark Truss Company, Inc., North Kingstown, RI 02852 Run: 8.53 S Jan 25 2022 Print: 8.530 S Jan 25 2022 MiTek Industries, Inc. Mon Apr 04 15:22:47 Page: 1 ID:ulNKfTZGBUmdwDjFGV8V6dzU4ZW-a0joKIHGUIWWQFl1yXggzrIqWEoHnudpyz5498zU3xs 4.512 =4x10 =4x4 =1.5x4 =3x4 =4x6 =3x6 =3x4 =1.5x4 =4x4 =4x10 91 12 11 10 2 8 3 7 4 62221 5 T1 T1 B1 B2 W2 W1 W2 W1 HW1 HW1 1-4-8 24-10-8 1-4-8 -1-4-8 5-8-12 17-5-12 5-8-12 11-9-0 6-0-4 23-6-0 6-0-4 6-0-4 6-10-6 15-2-3 8-3-13 23-6-0 8-3-13 8-3-135-2-130-9-95-2-7Scale = 1:46.7 Plate Offsets (X, Y): [2:0-5-13,Edge], [8:0-5-13,Edge], [8:0-0-0,0-0-0] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)30.0 Plate Grip DOL 1.15 TC 0.77 Vert(LL)-0.16 10-12 >999 360 MT20 197/144 Snow (Pf)30.0 Lumber DOL 1.15 BC 0.70 Vert(CT)-0.24 10-12 >999 240 TCDL 5.0 Rep Stress Incr YES WB 0.14 Horz(CT)0.06 8 n/a n/a BCLL 5.0*Code IBC2015/TPI2014 Matrix-MSH BCDL 10.0 Weight: 89 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x6 SPF 1650F 1.5E --2-6-0, Right 2x6 SPF 1650F 1.5E --2-6-0 BRACING TOP CHORD Structural wood sheathing directly applied or 2-8-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-8-11 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)2=1154/0-5-8, (min. 0-2-0), 8=1154/0-5-8, (min. 0-2-0) Max Horiz 2=214 (LC 16) Max Uplift 2=-505 (LC 19), 8=-505 (LC 15) Max Grav 2=1263 (LC 28), 8=1263 (LC 32) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-639/29, 3-4=-2073/851, 4-21=-1868/750, 5-21=-1813/762, 5-22=-1813/762, 6-22=-1868/750, 6-7=-2073/851, 7-8=-583/29BOT CHORD 2-12=-760/1940, 11-12=-409/1328, 10-11=-409/1328, 8-10=-682/1853 WEBS 5-10=-227/568, 6-10=-447/368, 5-12=-226/568, 4-12=-447/367 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=142mph (3-second gust) Vasd=112mph; TCDL=3.0psf; BCDL=6.0psf; h=16ft; B=26ft; L=26ft; eave=4ft; Cat. II; Exp C; Open; MWFRS (directional) and C-C Corner (3) -1-4-8 to 1-7-8, Exterior (2) 1-7-8 to 11-9-0, Corner (3) 11-9-0 to 14-9-0, Exterior (2) 14-9-0 to 24-10-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=30.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=30.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.20 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 30.0 psf on overhangs non-concurrent with other live loads. 6)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf (or less) is not adequate for a shingle roof. Architect to verify adequacy of top chord dead load.7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 505 lb uplift at joint 2 and 505 lb uplift at joint 8. 10)This truss is designed in accordance with the 2015 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply Cape Cod Inflatable Park -Restroom Q15315 A02 112Common Job Reference (optional) Stark Truss Company, Inc., North Kingstown, RI 02852 Run: 8.53 S Jan 25 2022 Print: 8.530 S Jan 25 2022 MiTek Industries, Inc. Mon Apr 04 15:22:48 Page: 1 ID:71TbgA5E3iAXbqVWI1QaLhzU4Yr-2DHBXeIuFbeN1PKDWEBvW2qvKe7QWMQyAcrehazU3xr 4.512 =3x8 =5x5 =3x6 =4x6 =5x5 =3x8 171 30 29 28 27 26 25 24 23 2221 20 19 18 2 16 153 144 1354039126 117810 9 T1 T1 B1 B2 ST6 ST6ST5 ST4 ST3 ST2 ST1 ST5 ST4 ST3 ST2 ST1HW1HW1 1-4-8 24-10-8 1-4-8 -1-4-8 11-9-0 23-6-0 11-9-0 11-9-0 23-6-05-2-130-9-95-2-72-0-0 Scale = 1:46.9 Plate Offsets (X, Y): [2:0-2-0,0-0-7], [3:0-2-8,0-2-4], [9:0-3-0,Edge], [15:0-2-8,0-2-4], [16:0-2-0,0-5-15], [21:0-3-0,0-1-4] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)30.0 Plate Grip DOL 1.15 TC 0.23 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf)30.0 Lumber DOL 1.15 BC 0.04 Vert(CT)n/a -n/a 999 TCDL 5.0 Rep Stress Incr YES WB 0.04 Horz(CT)0.01 16 n/a n/a BCLL 5.0*Code IBC2015/TPI2014 Matrix-MSH BCDL 10.0 Weight: 102 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x6 SPF 1650F 1.5E --1-9-6, Right 2x6 SPF 1650F 1.5E --1-9-6 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 23-6-0. (lb) -Max Horiz 2=214 (LC 16), 31=214 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 16, 25, 26, 31, 35 except 18=-116 (LC 15), 19=-115 (LC 15), 20=-110 (LC 15), 22=-116 (LC 15), 23=-111 (LC 15), 27=-116 (LC 19), 28=-110 (LC 19), 29=-115 (LC 19), 30=-133 (LC 19) Max Grav All reactions 250 (lb) or less at joint(s) 18, 19, 20, 22, 23, 24, 25, 26, 27, 28, 29, 30 except 2=274 (LC 8), 16=274 (LC 8), 31=274 (LC 8), 35=274 (LC 8) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=142mph (3-second gust) Vasd=112mph; TCDL=3.0psf; BCDL=6.0psf; h=16ft; B=26ft; L=26ft; eave=2ft; Cat. II; Exp C; Open; MWFRS (directional) and C-C Corner (3) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=30.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=30.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.20 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 30.0 psf on overhangs non-concurrent with other live loads. 7)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf (or less) is not adequate for a shingle roof. Architect to verify adequacy of top chord dead load. 8)All plates are 1.5x4 MT20 unless otherwise indicated. 9)Gable requires continuous bottom chord bearing. 10)Gable studs spaced at 2-0-0 oc. 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 13)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 25, 26, 16, 2, 16 except (jt=lb) 27=116, 28=109, 29=114, 30=132, 23=111, 22=116, 20=109, 19=114, 18=115. 14)This truss is designed in accordance with the 2015 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply Cape Cod Inflatable Park -Restroom Q15315 A02GE 12Common Supported Gable Job Reference (optional) Stark Truss Company, Inc., North Kingstown, RI 02852 Run: 8.53 S Jan 25 2022 Print: 8.530 S Jan 25 2022 MiTek Industries, Inc. Mon Apr 04 15:22:48 Page: 1 ID:qy3NnbCWinR6nMGRt8bwlozU4Yh-2DHBXeIuFbeN1PKDWEBvW2q2leHkWO?yAcrehazU3xr 212 4.512 =4x6 =2x4 =4x6 =3x6 =6x8 =2x4 =3x6 =4x6 =3x8 =5x5 =5x5 =3x6 =5x5 =3x8 =4x6 =3x6 =2x4 =6x8 =3x6 =4x6 =2x4 =4x6 151 24 23 22 21 20 19 18 17 16 2 14 36311334125113235610343379 8 T2 T1 T3 T3 T2 T1 B1 B1B3B2 W7 W6 W3 W7 W6 W5 W4W5W3W4 W2W1 W8 W9 1-4-8 49-5-0 1-4-8 -1-4-8 3-5-3 24-0-4 3-5-3 27-5-7 4-0-13 35-6-8 4-0-13 16-6-13 4-0-4 31-5-11 4-0-4 20-7-1 5-11-3 12-6-0 6-2-11 41-9-3 6-3-5 48-0-8 6-6-13 6-6-13 5-11-3 12-6-0 6-2-11 41-9-3 6-3-5 48-0-8 6-6-13 6-6-13 7-1-14 27-7-3 7-11-5 35-6-8 7-11-5 20-5-55-2-150-5-133-11-03-11-01-3-75-2-7Scale = 1:84.4 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)30.0 Plate Grip DOL 1.15 TC 0.73 Vert(LL)-0.08 24-27 >999 360 MT20 197/144 Snow (Pf)30.0 Lumber DOL 1.15 BC 0.43 Vert(CT)-0.14 21-23 >999 240 TCDL 5.0 Rep Stress Incr YES WB 0.82 Horz(CT)0.03 14 n/a n/a BCLL 5.0*Code IBC2015/TPI2014 Matrix-MSH BCDL 10.0 Weight: 176 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 9-1-1 oc bracing. WEBS 1 Row at midpt 3-23, 13-17 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 0-4-8. except 17=0-5-8, 23=0-5-8 (lb) -Max Horiz 2=257 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) except 2=-272 (LC 19), 14=-282 (LC 15), 17=-840 (LC 15), 23=-846 (LC 19) Max Grav All reactions 250 (lb) or less at joint (s) except 2=563 (LC 28), 14=570 (LC 32), 17=2043 (LC 32), 23=2039 (LC 28) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-31=-836/333, 3-31=-769/336, 3-4=-497/1115, 4-5=-493/1163, 5-32=-457/1148, 6-32=-453/1151, 6-33=-1032/433, 7-33=-987/435, 7-8=-1142/532, 8-9=-1127/527, 9-34=-972/429, 10-34=-1017/427, 10-35=-426/1098, 11-35=-430/1095, 11-12=-468/1113, 12-13=-472/1086, 13-36=-784/372, 14-36=-847/369 BOT CHORD 2-24=-401/850, 23-24=-401/850, 22-23=-129/467, 21-22=-129/467, 20-21=-172/729, 19-20=-172/729, 18-19=-66/438, 17-18=-66/438, 16-17=-315/808, 14-16=-315/808 WEBS 8-19=-164/451, 9-19=-624/314, 11-17=-522/329, 8-21=-149/468, 7-21=-625/309, 10-19=-202/691, 10-17=-1824/804, 6-21=-189/669, 5-23=-492/311, 6-23=-1816/799, 3-23=-1879/859, 13-17=-1918/877 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=142mph (3-second gust) Vasd=112mph; TCDL=3.0psf; BCDL=6.0psf; h=16ft; B=26ft; L=48ft; eave=6ft; Cat. II; Exp C; Open; MWFRS (directional) and C-C Corner (3) -1-4-8 to 3-5-2, Exterior (2) 3-5-2 to 24-0-4, Corner (3) 24-0-4 to 27-5-7, Exterior (2) 27-5-7 to 49-5-0 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-10; Pr=30.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=30.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.20 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 30.0 psf on overhangs non-concurrent with other live loads. 6)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf (or less) is not adequate for a shingle roof. Architect to verify adequacy of top chord dead load. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 272 lb uplift at joint 2, 839 lb uplift at joint 17, 282 lb uplift at joint 14 and 846 lb uplift at joint 23. 10)This truss is designed in accordance with the 2015 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply Cape Cod Inflatable Park -Restroom Q15315 B01 14Roof Special Job Reference (optional) Stark Truss Company, Inc., North Kingstown, RI 02852 Run: 8.53 S Jan 25 2022 Print: 8.530 S Jan 25 2022 MiTek Industries, Inc. Mon Apr 04 15:22:48 Page: 1 ID:1hO5VEaO5Vg4rjP9?N7QqdzU4Ww-2DHBXeIuFbeN1PKDWEBvW2qwxeBdWCpyAcrehazU3xr 212 4.512 =4x6 =4x6 =3x6 =8x10 =3x6 =4x6 =3x8 =5x5 =5x5 =3x6 =5x5 =3x8 =4x6 =3x6 =8x10 =3x6 =4x6 =4x6 261 42 4140 39 38 37 36 35 34 33 32 31 30 29 28 27 2 25 5246 5347 3 24 5448 6461 5145 4 2354943 6 22721820919 44 50 10 181117121663621315 14 T2 T1 T3 T3 T2 T1 B1 B1B3B2 W7 W6 W3 W8 W9 W7 W6 W3W2W1 W5 W4W5W4 ST8 ST7ST6ST5ST4 ST3ST2ST1 ST8 ST7 ST6 ST9 ST10 ST11 ST1 1-4-8 49-5-0 1-4-8 -1-4-8 3-5-3 24-0-4 3-5-3 27-5-7 4-0-4 35-6-8 4-0-4 16-6-4 4-0-12 31-6-4 4-0-12 20-7-1 5-11-3 12-6-0 6-2-11 41-9-3 6-3-5 48-0-8 6-6-13 6-6-13 5-11-3 12-6-0 6-2-11 41-9-3 6-3-5 48-0-8 6-6-13 6-6-13 7-1-14 27-7-3 7-11-5 35-6-8 7-11-5 20-5-55-2-150-5-133-11-03-11-01-3-75-2-7Scale = 1:84.4 Plate Offsets (X, Y): [30:0-2-4,0-2-8], [38:0-4-8,0-2-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)30.0 Plate Grip DOL 1.15 TC 0.57 Vert(LL)-0.11 42 >999 360 MT20 197/144 Snow (Pf)30.0 Lumber DOL 1.15 BC 0.48 Vert(CT)-0.17 42-57 >918 240 TCDL 5.0 Rep Stress Incr YES WB 0.84 Horz(CT)0.03 25 n/a n/a BCLL 5.0*Code IBC2015/TPI2014 Matrix-MSH BCDL 10.0 Weight: 197 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 5-1-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 8-11-2 oc bracing. WEBS 1 Row at midpt 17-30, 11-38 JOINTS 1 Brace at Jt(s): 47, 53 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 0-4-8. except 30=0-5-8, 38=0-5-8 (lb) -Max Horiz 2=257 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) except 2=-277 (LC 19), 25=-287 (LC 15), 30=-832 (LC 15), 38=-840 (LC 19) Max Grav All reactions 250 (lb) or less at joint (s) except 2=575 (LC 28), 25=584 (LC 32), 30=2025 (LC 32), 38=2026 (LC 28) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-865/337, 3-61=-838/356, 4-61=-832/357, 4-5=-813/355, 5-6=-506/1161, 6-7=-486/1152, 7-8=-484/1166, 8-9=-460/1105, 9-10=-451/1121, 10-11=-443/1138, 11-12=-1044/448, 12-62=-1029/456, 13-62=-1015/458, 13-14=-1164/553, 14-15=-1152/548, 15-63=-1004/453, 16-63=-1018/452, 16-17=-1033/443, 17-18=-417/1080, 18-19=-424/1060, 19-20=-435/1047, 20-21=-457/1106, 21-22=-459/1091, 22-23=-482/1103, 23-64=-823/395, 24-64=-852/393, 24-25=-879/377 BOT CHORD 2-42=-413/885, 41-42=-413/885, 40-41=-413/885, 39-40=-413/885, 38-39=-413/885, 37-38=-121/487, 36-37=-121/487, 35-36=-121/487, 34-35=-183/751, 33-34=-183/751, 32-33=-54/464, 31-32=-54/464, 30-31=-54/464, 29-30=-327/841, 28-29=-327/841, 27-28=-327/841, 25-27=-327/841 WEBS 14-33=-175/463, 15-33=-591/302, 30-52=-2050/925, 52-53=-1957/891, 53-54=-1941/876, 23-54=-1954/891, 23-28=-73/259, 14-35=-158/475, 13-35=-593/296, 5-48=-1926/877, 47-48=-1907/858, 46-47=-1922/873, 38-46=-2027/913, 5-40=-77/306, 33-49=-220/662, 17-49=-249/709, 17-50=-1809/805, 50-51=-1827/774, 30-51=-1835/794, 11-43=-239/690, 35-43=-211/644, 38-45=-1830/788, 44-45=-1819/767, 11-44=-1798/797, 8-46=-393/150, 20-52=-378/137 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-10; Vult=142mph (3-second gust) Vasd=112mph; TCDL=3.0psf; BCDL=6.0psf; h=16ft; B=26ft; L=48ft; eave=6ft; Cat. II; Exp C; Open; MWFRS (directional) and C-C Corner (3) -1-4-8 to 3-5-2, Exterior (2) 3-5-2 to 24-0-4, Corner (3) 24-0-4 to 27-5-7, Exterior (2) 27-5-7 to 49-5-0 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-10; Pr=30.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=30.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp C; Partially Exp.; Ct=1.20 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 30.0 psf on overhangs non-concurrent with other live loads. 7)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf (or less) is not adequate for a shingle roof. Architect to verify adequacy of top chord dead load.8)All plates are 2x4 MT20 unless otherwise indicated. 9)Gable studs spaced at 2-0-0 oc. 10)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 276 lb uplift at joint 2, 831 lb uplift at joint 30, 839 lb uplift at joint 38 and 287 lb uplift at joint 25. 13)This truss is designed in accordance with the 2015 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply Cape Cod Inflatable Park -Restroom Q15315 B01GE 12Roof Special Structural Gable Job Reference (optional) Stark Truss Company, Inc., North Kingstown, RI 02852 Run: 8.53 S Jan 25 2022 Print: 8.530 S Jan 25 2022 MiTek Industries, Inc. Mon Apr 04 15:22:49 Page: 1 ID:ICqTKhZKwOo1_hodzl2LLjzU4T3-WPrZl_JW0vmEfZuQ3yj82GN881W8Feo5PGaBE0zU3xq