HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. ILot Zone of Contribution: In Out XAcreage_
4,L(/ lin „J j�� Comme ---- Residential: x
Street: �� bb «<///��' b
Village: Floor Pl.a : n #Bedrooms: 3
Owner: Installer: 7 t k ips l k
Address: Phone:
Phone: /
Builder' Engineer: �'Ve(4 el
Address: Phone:
Phone:
N/A YES/.NO
1.Required# of copies received t
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table
4. Foundation 2 ft above high point of road H.P.: Fnd: Var_: v'
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: t
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var_:
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.: i
12. System meets all other setback requirements Var.: ✓
13. Uses adjustment for maximum high groundwater Var.: ✓r
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: v
15. System not in top or subsoil(A,B horizons) or 5' removal
16. Proposed contours are suitable ✓/
17. System meets slope requirements-min. 1/8", '/4"preferred ✓
18. System meets breakout requirements PVC liner: Wall: V,
19. Specified tee sizes are proper, gas baffle on outlet tee //
20. Sewage is under 10,000 gpd for parcel a/
21. No garbage disposal #c
22. System adequately sized for its intended use ,`/
23. Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6"of grade, pump chamber cover to grade ✓ ,-
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2" line,weep hole,check valve, tee in dbox,pump size ,
28. Septic tank/pump chamber to be factory waterproofed v
29. Vent provided if leaching below 3 feet, under driveway/parking
30. Buoyancy calculations for tank/pump chamber7
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature br
. 33. 1-1-20 loading is subject to vehicular traffic, groundwater /
34. Title V Application and permit fee, installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd f
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 11Jt41/�