Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 5 / Zone of Contribution: In Out'Acreage 7 'r 3, Commercial: Residential: Street: /1 S (.��/\) e 4;,..)ri L J cti 8-cA Village: _ Floor Plan: 'V #Bedrooms: Owner: IS l'/` r;, Set 1 o/�' Installer: 2_1, I C . Address: I Phone: Phone: Builder: Engineer: LS)W e c Ye r S ------------ Address: Phone: Phone: N/A YES NO 1. Required#of copies received 2.Date of soils exam and percolation test not older than 2 years Y/ 3.4-5 ft of naturally occurring pervious material,above water table _ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: . 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: \7; ‘,..r15. System not in top or subsoil(A,B horizons)or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred 18. System meets breakout requirements PVC liner: Wall: ,s7r. 19. Specified tee sizes are proper, gas baffle on outlet tee -v/ 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use V 23.Minimum 6"stone or compacted below tank and dbox ('' s--ti,,, e. v a,161- 13A 24. Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field N.Z.- 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 'V 28. Septic tank/pump chamber to be factory waterproofed \...../- 29. 29. Vent provided if leaching below 3 feet,under driveway/parking I' 30.Buoyancy calculations for tank/pump chamber 1/ V 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature i 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee,installer signature I J 35.Foundation footing min.2 feet above adjusted ground water for new house / 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by 6 0303