HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot 1 Zone of Contribution: In Out )( Acreage
2% h�� Commercial: Residential:
Street: K7
4-a 12
Village: Floor Plan: #Bedrooms: 3
Owner: Installer: Pt 8
Address: Phone:
Phone: '/ WA
VIA
Builder: Engineer: 3`V1 . /Y�'"` S
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received ✓
ate of soils exam and percolation test not older than 2 years
4-5 ft of naturally occurring pervious material,above water table Will£ 7411 SS 1t4St4 tt V,-
4.
L4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ /
5. Water line 10 ft from septic components Var.: ✓
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: V
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: :>:,..,
11. Tank/leaching minimum 10 ft from property line Var.: ✓
12. System meets all other setback requirements Var.: /
13.Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: V:
15. System not in top or subsoil(A,B horizons)or 5' removal ✓/
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", '/"preferred ✓ /
18. System meets breakout requirements PVC liner: Wall: ✓�
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
Vx
21.No garbage disposal ✓
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox it//:2 ‘
24.Manhole covers within 6"of grade,pump chamber cover to grade
25. Inspection port on plastic chambers/leach field
26.Electrical permit for pump chamber/Separate meter for duplexes ,./j
27. Pump system-2"line,weep hole,check valve, tee in dbox,pump size 1/
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking ✓/
30. Buoyancy calculations for tank/pump chamber V /
31. Engineer to inspect and certify soils: wall: commercial: ✓/
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V
33.H-20 loading is subject to vehicular traffic, groundwater ✓ ,
34. Title V Application and permit fee, installer signature /
35.Foundation footing min. 2 feet above adjusted ground water for new house ✓
36.Deed Restriction required max. #bedrooms: max. flow: gpd v" /
37. Check area lots for groundwater/Lab-1 ',10 r dwater in Asses'or's Map ✓
Plan reviewed by: 6/03/03