HomeMy WebLinkAbout2022 May 25 - O&M Inspection Report from Coastal Engineering Co. • TRANSMITTAL 260 Cranberry Highway COASTAL508.255.65Orlpea5 8,.M25A5.067206053F engineering co. Orleans I Sandwich I Nantucket TECHNICAL SERVICES coastalengineeringcompany.com To: Department of Environmental Protection Date: 06/15/2022 Project No. WYA024.00 Attn: Title 5 Program Via: ®1st Class Mail (Pick up Delivery Fed Ex One Winter Street, 6th Floor Boston, MA 02108 Subject: Bioclere Treatment System Operation 6 Maintenance Shaw's Supermarkets, Inc. RECEIVED 1106 Route 28 South Yarmouth, MA JUN 21 2022 PILOTING USE PERMIT HEALTH DEPT. Plans Copy of Letter ' Specifications ® Other We are sending the following items: Copies Date No. Description 1 05/25/2022 WYA024.00 0&M Inspection Form 6 DEP Inspection Form 1 05/11/2022 WYA024.00 Laboratory Test Results These are transmitted as checked below: ofor approval for your use ®as requested for review 6 comment LJ Remarks: Enclosed is the recent 06M inspection form for the system at the above referenced location. The average daily flow during this reporting period was 3,217 gallons per day. The 0&M inspection form indicate the system is operating properly. Test results indicate good treatment of the system. Please do not hesitate to contact us if you have any questions or comments. cc: AquaPoint.3 LLC By: Chad A. Simmons Yarmouth Board of Health Donna Connerty, Shaw's Supermarkets CAS/acc NOTE: If enclosures are not as noted, please contact us at (508) 255-6511 D:\DOC\W\WYA\024\Transmittals\Transmittal (May 2022).doc 260 Cranberry Highway,Orleans,MA 02653 Orleans I Sandwich I Nantucket 508.255.6511 I coastalengineeringcompany.corn PILOTING PERMIT No.: W033722 NAME OF PROJECT: Shaw's Supermarket, Inc. FACILITY LOCATION: 1106 Route 28 South Yarmouth, MA O&M INSPECTION DATE 5/25/2022 PARAMETER UNITS EFFLUENT pH pH units 7.50 Flow (avg. daily) gpd 3,217 TKN mg/L 3.39 Nitrite-N mg/L 0.28 Nitrate-N mg/L 0.73 Total Nitrogen mg/L 4.40 REMARKS: Test results indicate good treatment of the system. D:\DOC\W\WYA\024\[DMR summary.xls]05-2022 Serial_No:05312210:20 FILED ON BOH • '3 1 zap" MA1„,,,y17- ' CAL ANALYTICAL REPORT Lab Number: L2224885 Client: Coastal Engineering Company 260 Cranberry Highway Route 6A Orleans, MA 02653 ATTN: Chad Simmons Phone: (508)255-6511 Project Name: SHAW'S SUPERMARKET Project Number: WYA024.00 Report Date: 05/31/22 The original project report/data package is held by Alpha Analytical.This reporUdata package is paginated and should be reproduced only in its entirety.Alpha Analytical holds no responsibility for results and/or data that are not consistent with the original. Certifications&Approvals:MA(M-MA086),NH NELAP(2064),CT(PH-0574),IL(200077),ME(MA00086),MD(348),NJ(MA935),NY(11148), NC(25700/666),PA(68-03671), RI(LA000065),TX(T104704476),VT(VT-0935),VA(460195),USDA(Permit#P330-17-00196). Eight Walkup Drive, Westborough, MA 01581-1019 508-898-9220 (Fax) 508-898-9193 800-624-9220-www.alphalab.com Page 1 of 16 Serial No:05312210:20 Project Name: SHAW'S SUPERMARKET Lab Number: L2224885 Project Number: WYA024.00 Report Date: 05/31/22 SAMPLE RESULTS Lab ID: L2224885-01 Date Collected: 05/11/22 08:15 Client ID: EFFLUENT Date Received: 05/11/22 Sample Location: 1106 ROUTE 28, SOUTH YARMOUTH, MA Field Prep: Not Specified Sample Depth: Matrix: Water Dilution Date Date Analytical Parameter Result Qualifier Units RL MDL Factor Prepared Analyzed Method Analyst General Chemistry-Westborough Lab Nitrogen,Nitrite 0.28 mg/I 0.050 -- 1 - 05/12/22 06:26 44,353.2 KA Nitrogen,Nitrate 0.73 mg/I 0.10 1 05/12/22 06:26 44,353.2 KA Nitrogen,Total Kjeldahl 3.39 mg/I 0.300 -- 1 05/26/22 23:20 05/27/22 20:48 121,4500NH3-H AT Page 5 of 16 . , • SerialNo:05312210:20 CHAIN OF CUSTODY RAGE i OF i Date Reed in Latx -,. ALPHA Job#: ' ? L - ;IALPHA project information Report I formation Data Billing Information ,i s Deliverab es 0 FAX rg EMAIL 0 Same as Client irk 1 PO P. . „.. WOStbOrOttelt,IAA Mansfield,IAA 0 ADEA 0 Arid i Stelmeralisies Protect Name:Shrds Supermarket TEL 50s-issitPa= TEL:Entii-all2-gaQil PAX 508,satinnta PAX SCia-1322-32ES Regulatory Requirements/Rep rt Limits Project Location:1106 Route 28,South Yarmouth, NIA =:::11111111111111111111___ StawTevi Pf041 atri t....icatig Client,Coastal Engineering Co,Inc. Project*:WYA024.00 MCP PRESUMPTIVE CERTAINTY-CT REASONABLE CONFIDENCE PROTOCOLS 0 Yes a Eta Are MCP Analpear tiletlrpls Required? Address:260 Cranberry Highway _Project Manager:Chad A.Simmons C",)Yes 1 0 Na Are CT RCP(Reason**Confreense Prolocers)Required" . Orleans.MA02653 ALPHA Quote d,2011601revl ANALYSIS T o eh_.....a........,.... !!!!!!!!fflig,..E3 pp SALIKE PfANSPANS T A RWIrl/W1 l Fax;508 255-6700 El Standard 0 Rush colily e PlIE-AFTRWEDi 0 Dens 0 Nat Netded # Email.:cairomonsdiceocapecod.com ' CI Lati to do a 0 Tt1944 U.11,,C4*beer berm Preacerere resepee by Alpha Due Date: Time: Prawatfon 0 0 Lab to du 7 Other Project Specific Requirements/Comments/Detection Limits: eemos,ii vi.iet L pH: see* F s es o z 'ALPHA Lab ID ' Sample ID colecaion SampIa Sampler's '61 3 Samuitt Sp•calis Lab Use O Dam Time Matrix Initiate Z iiii Gamow.* —.— -g-tiaa 37_,04_,, ffluent 571#42., gic WW T-105 E 6 ii s is Illieji Lal 0 ILI a 0 DOEI • saiss . 00 " El -Ei 'ra- o 0 0 0 0 0 Ell 0 0 ... 'E3--0 in -0 0000notno Es ID-1:1-El 0 s El 0 0 0 0 E3 O 90000000000 , . I i 0 0 0 0 0 0 0 0 0 0 0 0 ...., . . ID DDDDDDDDDDD O 000 . 111 • 100000 O 0-0 0 i El r.3 0 El 0 ' DOD PLEASE ANSWER QUESTIONS ABC) 51 container Type i's P Mean pent*arty ieili* Preservative A 0 Jand sereseltry.Sew:Wean IS YOUR PROJECT Reline By. Daterrene Date/Time Y., net ea logarreineed . lupasietne liesedociP MP nal MA MCP or CT RCP? xi. ,..0,..; 4„.....„ ... , , start itattl anyambigallas ate 4-6'/._i , sweet All retorople$, A.,...„, ,A sulastatal ant atbil ,.. -"""Page 16 of 16 Massachusetts Department of Environmental Protection - Bureau of Resoure Protection - Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems Important:When filling out forms on A. Installation the computer,use only the tab key to Shaws Supermarkets, Inc. move your cursor Owner do not use the 1106 Route 28 return key. Facility Street Address Yarmouth 02664 r= City Zip Mailing address of owner, if different: ( �I P.O. Box 600 Street Address/PO Box: East Bridgewater 02379 City State Zip Telephone Number B. Authorized Service Provider Coastal Engineering, Co. Inc. O&M Firm 260 Cranberry Highway Street Address Orleans MA 02653 City State Zip 508-255-6511 Telephone Number Jeff Selens 11444 Certified Operator Name Certification Number C. Facility/System Information W033722 30 Series DEP ID Manufacturer ID Model Number 2005-06-03 2005-06-03 Installation Date Start of Operation Approval Type: ❑ General ❑ Provisional X] Piloting ❑ Remedial Seasonal Residence - used less that 6mo./year: ❑ Yes ] No D. Operating Information 2022-05-25 1 Inspection Date Previous Inspection Date Pumping Recommended ❑ Yes X❑ No Sludge Depth BureauMassachusettsof DepartmentResoureProtection of - EnvironmentalTitle5 Protection DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems E. Field Testing Field Inspection: Color: ❑ Gray ❑ Brown ❑ Clear Turbid Slight amber X Other(specify) Odor: X Musty ❑ Earthy ❑ Moldy El Offensive E Turbid Effluent Solids: ] No ❑; Some pH 7.6 SU DO 0 mg/L Turbidity 0 NTU 6 to 9 2 or greater 40 or less Should a Remedial or General Use system fail the Field Testing, effluent samples shall be collected per Standard Methods and analyzed for BOD and TSS. F. Sampling Information Samples Taken: ❑ Influent � Effluent Commercial systems or systems with a design flow of 2000 gpd and greater, and General Use nitrogen reducing systems: 3217 gpd Parameters sampled:W pH ❑ BOD ❑ CBOD ❑ TSS V TN ❑ Other(list below) Other 1 Other 2 Other 3 G. Inspection and Maintenance Description of any maintenance performed since previous inspection &during this inspection: Operation and maintenance conducted—system operational at the time of the visit. Notes and Comments: Operation and maintenance conducted—system operational at the time of the visit. BureauMassachusettsof DepartmentResoureProtection of - EnvironmentalTitle5 Protection DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems H. Certification I certify: I have inspected the sewage treatment and disposal system at the address above, have conducted the required Field Testing and/or sample collection in accordance with Standard Methods, have completed this report and the attached technology operation and maintenance checklist, and the information reported is true, accurate, and complete as of the time of the inspection. I am a Massachusetts -• ;e,§f opkTa;r in accordance with 257 CMR 2.00. / /r f _ 2022-05-25 Operator Sign re't" Date lrY'`' System owner must submit this report, technology O&M checklist, and any required sampling results to the local board of health as follows for each inspection performed: Remedial Use- by January 31st of each year for the previous calendar year Piloting Use-within 45 days of inspection date Provisional Use- by March 31St of each year for the previous 12 months General Use-by September 31St of each year for the previous 12 months Send to: Department of Environmental Protection Attention: Title 5 Program One Winter Street 5th Floor Boston, MA 02108 6/15/22,10:30 AM Permitlnspections s: Y h m a r _ _ -- _ '. i.:w:ie..eeaixi r• Chad Simmons-Coastal Engineering,Co. Inc. 10:30 am Main Submit My Clients My Reports',Help Home>Inspections>View Inspection 0 Cancel Property Details Inspection Address 1106 Route 28,Yarmouth Print Inspection., Owner Shaws Supermarkets, Inc. Inspection Details Component: Bioclere Date: 2022-05-25 Time: 08:30:00 Operator Name: Jeff Selens License#: 11444 _ € i Operation and maintenance conducted—system operational at the time of the visit. Field Testing Color: Slight amber Odor: Musty Effluent Solids: No pH: 7.6 SU Dissolved Oxygen: mg/L Turbidity: NTU Settleable Solids: 1111.111.1Seasonal Residence: No Air Temperature: °F Weather Conditions: Operating Information Sludge Depth: in Scum Layer Thickness: in Pumping Recommended: No _Soil Absorption y em bs rvations . Signs of Breakout: No Depth of Ponding: in Ponding Above Invert: No Any Apparent Violations of the Approval? None Reported Any Cleaning or Lubrication of Parts Performed? Cleaned and brushed nozzles to ensure an efficient spray. Any Control Adjustments Made? None Reported https://septic.bamstablecountyhealth.org/app/permit inspections/view/7TI1YyvQ3Fd5NxBstVywSw 1/2 • 6/15/22, 10:30 AM Permitlnspections Pumps,Switches,Alarms Tested? Checked panels,timers,amps,switches,tank levels, alarms,and general condition of the system. (! i _ I 3 Any Equipment Failures? None Reported Any Parts Replaced? None Reported Any Recommended Corrective Actions? None Reported 'Inspection Completion .. 9 Inspection Completed? Yes Technology Checklist Odor Around Site Yes! No 1 - i Source of Odor Not Reported. Check all that apply „ w E f Scum Depth in Primary Tank Not Reported. Sludge Depth in Primary Tank Not Reported. _ I Does Grease Trap Need Pumping Yess No Unit 1 Air Passing Through Vent Fan Operating .f General External Damage I;YesLJ No Cover/Fan Box/Ctrl Panel Locked `fYes°No Flies on the Unit riYes No' Number of Flies Fewer Many Location of flies Not Reported. _ 77 Locks/Latches/Handles Ok 2Yes[ No Lid Gasket Ok Yes 1_ No Standing Water in Fan Box I ;Yes No g. r� https://septic.barnstablecountyhealth.org/app/permit_inspections/view/7TI1 YyvQ3Fd5NxBstVywSw 2/2