Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In Out X Acreage Commercial: Residential: Street: c 7k'leu C Village: Floor Plan: fl c # Bedrooms: ,. Owner: Installer: DtI 14 Za -Xra V417 14.) Address: Phone: Phone: q Builder: Engineer: i4k If-e1 .- A5 eiC' Address: Phone: Phone: yields l I ' N/A YES NO 1.Required# of copies received 2.Date of soils exam and percolation test not older than 2 years t/ 3. 4-5 ft of naturally occurring pervious material, above water table ;/" Foundation 2 ft above high point of road H.P.:(14,,S-4,,S- Fnd:614.5-Var.: 4 x 4 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands t 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: NZ 9.Leaching minimum 100 ft from wetlands Var.: ./ 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t/- 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: ;/ 13. Uses adjustment for maximum high groundwater Var.: 14.Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓ 15. System not in top or subsoil(A,B horizons) or 5' removal /V/ 16.Proposed contours are suitable V 17. System meets slope requirements—min. 1/8", 1/4"preferred / 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee ✓ 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6" stone or compacted below tank and dbox ✓ 24.Manhole covers within 6"of grade, pump chamber cover to grade v/ 25. Inspection port on plastic chambers/leach field V 26. Electrical permit for pump chamber/Separate meter for duplexes / 27.Pump system-2" line,weep hole,check valve, tee in dbox,pump size V / Septic tank/pump chamber to be factory waterproofed �/ frt 9 Vent provided if leaching below 3 feet, under driveway/parking Adel l/obf x Buoyancy calculations for tank/pump chamber V Engineer to inspect and certify soils: wall: commercial: Engineer/Registered Sanitarian and Land Surveyor stamps/signature H-20 loading is subject to vehicular traffic, groundwater } 3 l ti (CVtK1 i/Vit-11 F-IZP )( Title V Application and permit fee, installer signature 46. ,�c� Foundation footing min. 2 feet above adjusted ound water for new house 1 ,01 ' ( • Deed Restriction required max. #bedrooms: max. flow: gpd 'k\ 37. Check area lots for groundwater/Label groundwater in Assessor's Map I/ Plan reviewed by: YVU/1/ 6103/03